EVENT LOG FOR SITE BO1 The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/22/2011 08:54 cloughd@ TASS processing for BO1 was suspended on 22 Dec 11, because the site had been dewatered and consequently was generating lots of alarms and noise data. Processing will be reinstated when the site is watered up again. -Doug- 12/16/2011 07:20 darren@b 01:TestTagFailure,02:TestTagFailure,03:TestTagFailure,04:TestTagFailure: Clearing TASS. Site Down. 12/15/2011 07:39 Troy@bay 01:TestTagFailure,02:TestTagFailure,03:LowExcCurrent,03:TestTagFailure,04: LowExcCurrent,04:TestTagFailure,07:LowExcCurrent,07:TestTagFailure,0E:LowE xcCurrent,1C:LowExcCurrent: It appears this site is de-watered. PSMFC will confirm and up date the obs status page. 12/13/2011 07:39 Darren PSMFC was informed today by site Biologist Jon Rerecich that the ladder went ot an orifice flow yesterday (12-12-11) around 13:00. It will remain this way in preparation for the ladder being de-watered tomorrow (12-14- 11). 12/10/2011 08:18 darren@b 07:LowExcCurrent: Clearing TASS. Old alarm. 12/08/2011 07:08 darren@b 17:TestTagFailure: Clearing TASS 12/05/2011 07:43 alan@bay 17:TestTagFailure,1B:TestTagFailure,1C:LowExcCurrent: B-Branch down, clearing TASS. 12/02/2011 08:43 darren@b 17:TestTagFailure,1B:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Clearing TASS. 11/29/2011 15:24 Alan Manually pushed BO111333.D1 and E1 to PTAGIS without any trouble. 11/27/2011 12:56 scottl@b 04:TestTagFailure: Noted 11/22/2011 07:45 Troy@bay 02:TestTagFailure,04:TestTagFailure,12:BadOscFreq,17:TestTagFailure,1C:Low ExcCurrent: The slot and A branch alarms were addressed yesterday during a site GMC. Clearing TASS for the others. 11/21/2011 12:31 Darren A site GMC was performed today (11-21-11). All transceivers were checked and adjusted for tuning, noise, and detectability. No problems were discovered during this visit. The Clocks were adjusted as necessary to get the clocks within 1 second of atomic time and each other. No PIT tag detections were observed during this process. 11/20/2011 10:44 scottl@b 02:TestTagFailure,04:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent: noted, site needs tuned 11/18/2011 07:30 darren@b 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Clearing TASS. This branch of the ladder is currently de-watered due to repairs of the ladder. 11/18/2011 07:29 darren@b 04:TestTagFailure: This system is slightly out of tune and will be addressed during the next site visit. 11/18/2011 07:28 darren@b 02:TestTagFailure: System is out of tune and will be addressed during the next site visit. 11/12/2011 07:09 Troy@bay 02:TestTagFailure: This will be addressed on the next site visit. 11/10/2011 08:07 Troy@bay 02:TestTagFailure: This will be addressed on the next site visit. 11/09/2011 07:32 Troy@bay 02:TestTagFailure: This will be addressed on the next site visit. 11/08/2011 07:20 Troy@bay 02:TestTagFailure: Noted 11/07/2011 07:25 Troy@bay 02:TestTagFailure,15:TestTagFailure: Noted 11/06/2011 08:29 alan@bay 02:TestTagFailure: Noted 11/05/2011 09:52 alan@bay 02:TestTagFailure: This will be investigated during the next site visit. 11/04/2011 07:23 alan@bay 15:TestTagFailure,17:TestTagFailure,1B:TestTagFailure: Noted 11/04/2011 07:23 alan@bay 02:TestTagFailure: These alarms will be investigated during the next site visit. 11/03/2011 07:37 alan@bay 02:TestTagFailure,15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent: These alarms will be investigated during the next site visit. 11/01/2011 06:54 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent: B-Branch is dewatered 10/31/2011 06:51 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Clearing TASS, branch is dewatered. 10/30/2011 07:50 darren@b 15:TestTagFailure,17:TestTagFailure: clearing TASS. Systems are currently de-watered. 10/29/2011 07:49 darren@b 02:TestTagFailure,15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21: LowExcCurrent: The alarms on antenna 02 will be addressed during the next site visit. The alarms on the other systems are due to the ladder being de-watered. 10/26/2011 06:11 darren@b 04:TestTagFailure: Alarm will be addressed during the next site visit. 10/25/2011 06:43 darren@b 15:TestTagFailure: Alarm is on an antenna that is currently de-watered. 10/24/2011 07:07 darren@b 15:TestTagFailure: This branch of the ladder is currently de-watered. 10/24/2011 06:28 darren@b 15:TestTagFailure,1C:LowExcCurrent: ladder down. Clearing TASS. 10/23/2011 06:39 rclark@b 15:TestTagFailure,1C:LowExcCurrent: The ladder is de-watered. 10/22/2011 07:32 rclark@b 15:TestTagFailure,1C:LowExcCurrent: Ladder is de-watered. 10/21/2011 06:31 Darren A site GMC was performed yesterday (10-20-11). The slot antennas were adjusted for tuning, noise and detectability. No other problems were discovered. 10/21/2011 06:12 Rclark@b 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent: Ladder is de- watered. 10/17/2011 06:51 darren@b 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Clearing TASS. This section of the ladder is currently de-watered for construction. 10/16/2011 07:08 rclark@b 15:TestTagFailure,1B:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Ladder is dewatered. 10/15/2011 06:35 rclark@b 15:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Ladder is dewatered. 10/14/2011 11:12 rclark@b 15:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Ladder is dewatered. 10/13/2011 06:08 Rclark@b 15:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:LowExcCurrent: Ladder is dewatered. 10/12/2011 12:13 Rclark@b 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Ladder is dewatered. 10/11/2011 06:02 Rclark@b 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Ladder is dewatered. 10/11/2011 06:01 Rclark@b 03:TestTagFailure: Reader was retuned and timer tag level was increased during site visit on 10/11/2011. 10/11/2011 06:00 Rclark@b 01:LowExcCurrent: Caused by PSMFC persnel during site visit. 10/10/2011 06:10 Rclark@b 03:TestTagFailure,15:TestTagFailure,1C:LowExcCurrent: 03 - will be addressed during next site visit. 15, 1C - ladder is dewatered. 10/09/2011 07:57 Troy@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Ladder is de-watered, clearing TASS. 10/09/2011 07:56 Troy@bay 03:TestTagFailure: This alarm has been documented. The TT pot will be re- adjusted on the next site visit. 10/08/2011 07:16 Troy@bay 03:TestTagFailure,15:TestTagFailure: 03 will be adjusted on the next site visit. 15 is de-watered. 10/07/2011 06:59 Rclark@b 02:TestTagFailure,03:TestTagFailure,15:TestTagFailure: 02, 03 - may be slightly out of tune. Will address during next site visit. 15 - ladder is currently dewatered. 10/06/2011 06:34 Troy@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: These alarms are the result of the ladder being de-watered. Clearing TASS. 10/06/2011 06:33 Troy@bay 03:TestTagFailure: It appears the TT pot is not set correctly. The efficiencies are high for this system. PSMFC will address on the next site visit. 10/05/2011 06:40 Troy@bay 03:TestTagFailure: This may be the result of a GMC. PSMFC will monitor. Efficiencies are still good on the system. 10/03/2011 06:43 Troy@bay 15:TestTagFailure,1B:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: This ladder is de-watered, clearing TASS. 10/02/2011 06:39 alan@bay 1C:LowExcCurrent,1E:LowExcCurrent: Noted 10/01/2011 07:43 alan@bay 03:TestTagFailure: No apparent reason (a fish was lurking around that time) for this alarm. PTAGIS Field Operations will continue to monitor. 10/01/2011 07:41 alan@bay 15:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:LowExcCurrent: Noted 09/30/2011 06:34 Scott_Li Project will begin complete dewatering of B-Branch on 26 Sept, take WS to orifice flow (UMT to TW) on 14 Oct., and dewater WS on 17 Oct. 09/29/2011 06:38 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Noted 09/28/2011 06:50 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Noted 09/27/2011 06:34 alan@bay 15:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:LowExcCurrent: Noted 09/26/2011 10:51 Alan A GMC was performed 9-26-2011. All transceivers were checked and tuned as necessary. Outstanding files on PC2 were archived. Both PCs are within one second of atomic time. No problems found. 09/26/2011 06:19 scottl@b 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Will investigate today during the site GMC. 09/25/2011 09:54 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent,22:LowExcCurrent: Noted 09/24/2011 07:28 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,1E:O verrun,21:LowExcCurrent,22:LowExcCurrent: Noted 09/23/2011 06:51 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent,22:LowExcCurrent: Noted 09/22/2011 06:34 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,1E:LowExcCurrent,21:L owExcCurrent: Noted 09/21/2011 06:34 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Noted 09/20/2011 07:14 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Noted, B-branch is dewatered. 09/19/2011 06:53 alan@bay 02:TestTagFailure: A PIT tag was in the field when the timer tag was fired. 09/19/2011 06:53 alan@bay 0D:TestTagFailure: No apparent reason for this one-time alarm. PTAGIS Field Operations will continue to monitor. 09/19/2011 06:50 alan@bay 15:TestTagFailure,17:TestTagFailure,1C:LowExcCurrent,21:LowExcCurrent: Alarms are due to the emergengy operation of the ladder. 09/19/2011 06:49 Alan In an emergency repair operation, the USACE took the ladder to orifice flow at ~1300PST 9-16-2011. At ~1000PST 9-17-2011 the B-branch was dewatered and the A-Branch was returned to service. The ladder is expected to return to normal operations by 10-15-2011. 09/18/2011 07:30 darren@b 02:TestTagFailure,0E:TestTagFailure,15:TestTagFailure,16:LowExcCurrent,17: TestTagFailure,1B:LowExcCurrent,1C:LowExcCurrent,1E:LowExcCurrent,21:LowEx cCurrent,22:LowExcCurrent,24:TestTagFailure: These alarms are due to the emergency operations of this site. 09/17/2011 07:22 darren@b 02:TestTagFailure,08:LowExcCurrent,15:TestTagFailure,1C:LowExcCurrent,1E:L owExcCurrent,21:LowExcCurrent,22:LowExcCurrent: PSMFC was contacted by COE personnel about this ladder having an emergency shut down. The ladder will be out of commission until further notice. 09/08/2011 15:12 Alan The slots were tuned 9-8-2011. The circuit breaker for transceiver 04 tripped and was reset. No other problems to report. 08/30/2011 12:12 scottl Performed site GMC, all transceivers were retuned and calibrated as necessary. No problems to report. 08/10/2011 09:49 Alan A GMC was performed 8-10-2011. All transceivers were checked and tuned as necessary. Outstanding files on PC2 were archived. Both PCs are within one second of atomic time. No problems to report. 08/06/2011 07:52 Troy@bay 04:TestTagFailure: Noted 08/03/2011 06:25 Troy@bay 01:TestTagFailure,11:LowExcCurrent,21:LowExcCurrent: These alarms will be addressed on the next site visit. 07/22/2011 13:33 Troy@bay 01:TestTagFailure: This will be addressed on the next site visit. 07/17/2011 08:05 darren@b 21:TestTagFailure: There was a PITtag in the field while the timer tag was trying to fire. 07/15/2011 09:26 Roger Performed site GMC on 7/15/2011. All transceivers were checked for tune and adjusted as needed. PC1 and PC2 are within 1 second of atomic time and each other. No problems to report. 07/06/2011 10:15 Alan Addendum to previous pitevent: Outstanding files on PC2 were archived, both PCs are within one second of atomic time. 07/06/2011 09:53 Alan A GMC was performed 7-6-2011. All transceivers were checked and tuned as necessary. An ISP speedtest (dslreports.com) shows 748 up and 1247 down on PC2. The utility PC is all but unuseable. No problems to report. 07/01/2011 07:56 Rclark@b 08:LowExcCurrent,11:LowExcCurrent,1C:LowExcCurrent,1E:LowExcCurrent,21:Low ExcCurrent,22:LowExcCurrent: Left a message with the site bio to see if there was possibly any water level event. No problems were noted during the site GMC on 6/30/2011. 07/01/2011 07:25 Rclark@b 23:Overrun: Will investigate again during next site visit. 06/30/2011 10:53 Roger Performed site GMC on 6/30/2011. All transceivers were checked for tune and adjusted as needed. Transceiver 23, which had intermittant overruns, had sluggish keypad response. Swapping the analog board resolved this issue. PC1 and PC2 are within 1 second of atomic time and each other. No other problems to report. 06/29/2011 06:52 Rclark@b 23:Overrun: Will investigate during next site visit. 06/28/2011 07:21 Rclark@b 23:Overrun: This will be investigated during the next site visit. 06/24/2011 07:29 Troy@bay 03:LowExcCurrent,19:LowExcCurrent: These alarms occurred as a result of tuning during a GMC. 06/23/2011 09:55 Roger Performed site GMC on 6/23/2011. All transceivers were checked for tune and adjusted as needed. PC1 and PC2 are within 1 second of atomic time and each other. No problems to report. 06/22/2011 07:29 Troy@bay 23:Overrun: This alarm will be addressed tomorrow during a site visit. 06/17/2011 07:43 alan@bay 23:TestTagFailure: Clearing TASS, this was addressed during a site visit 6-16-2011. 06/16/2011 10:01 Roger Performed site GMC on 6/16/2011. All transceivers were checked for tune and adjusted as needed. Increased the VTT level on transceiver 23 to obtain 100% hit rate. PC1 and PC2 are within 1 second of atomic time. No problems to report. 06/15/2011 08:16 alan@bay 23:TestTagFailure: Alarm has been noted and will be investigated during the next site visit. 06/14/2011 07:33 alan@bay 23:TestTagFailure: Alarm has been noted and will be investigated during the next site visit. 06/13/2011 07:50 alan@bay 23:TestTagFailure: Alarm has been noted and will be investigated during the next site visit. 06/12/2011 06:38 darren@b 23:TestTagFailure: Alarm has been noted and will be investigated during the next site visit. 06/11/2011 06:26 darren@b 23:TestTagFailure: This alarm will be investigated during the next site GMC. 06/10/2011 07:06 darren@b 23:TestTagFailure: This system will be investigated during the next site visit. 06/09/2011 07:14 darren@b 23:TestTagFailure: The status report indicates that the transceiver is slightly out of tune. This may be the cause of the timer tags failing. This will be addressed during the next site visit. 06/08/2011 14:00 darren@b 23:TestTagFailure: No direct for this failure. PSMFC will monitor and correct the problem during the next site visit. 06/07/2011 10:09 Roger Performed site GMC on 6/7/2011. Checked all readers for tune and adjusted as needed. The exciter current alarm threshhold on coil 19 was lowered by 0.2A PC1 is 20 seconds behind atomic time. PC2 is 30 seconds behind atomic time. No problems to report. 06/07/2011 08:49 alan@bay 04:TestTagFailure,19:LowExcCurrent,23:TestTagFailure: These will be addressed today during a site visit. 06/03/2011 11:05 Troy A site GMC was performed 06/03/2011. All transceivers were checked for tune and adjustments made where needed. No problems to report. 06/02/2011 07:08 Troy@bay 23:TestTagFailure: This should be addressed today during a GMC. 05/31/2011 07:33 alan@bay 23:TestTagFailure: This xcvr is experiencing slight noise but is reading PIT Tags well. Perhaps the VTT couls use an adjustment. This will be investigated during the next site visit. 05/30/2011 07:12 alan@bay 23:TestTagFailure: This xcvr is experiencing slight noise but is reading PIT Tags well. This will be investigated during the next site visit. 05/29/2011 10:11 alan@bay 23:TestTagFailure: This xcvr is experiencing slight noise but is reading PIT Tags well. PTAGIS Field Operations will continue to monitor. 05/28/2011 07:17 alan@bay 23:TestTagFailure: This xcvr is experiencing slight noise but is reading PIT Tags well. PTAGIS Field Operations will continue to monitor. 05/27/2011 07:29 alan@bay 0A:Overrun,0A:TestTagFailure,22:LowExcCurrent,23:LowExcCurrent,23:Overrun, 23:TestTagFailure: These alarms were generated by PTAGIS Field Operations personnel during a site visit. 05/26/2011 12:56 Troy A site GMC was performed 05/26/2011. All transceivers were checked for tune and adjustments made where needed. 23 was replaced due to tripping the CB every time it was plugged in. There may be some bad data in the raw file as the parameters had not been reset on the replacement transceiver after being flashed so for a brief moment there was a transceiver 0A connected to the platform. The replacement transceiver was current calibrated and the Current Alarm Threshold set (22 was cal'ed and adjusted as well). This transceiver is experiencing overruns. PSMFC will watch to see if this settle out and take action as necessary. No other problems to report. 05/22/2011 07:48 Troy 23 appears to have died. This will be investigated on the next site visit. 05/17/2011 11:36 Darren A site GMC was performed today (5-17-11). All transceivers were checked for tuning, noise and detectability. No problems were discovered during this visit. 05/17/2011 07:22 Troy@bay 01:HighTemp,04:TestTagFailure: These alarms will be addressed on the next site visit. 05/15/2011 09:26 scottl@b 01:HighTemp,04:TestTagFailure: High temp alarms are more than likely caused by the heater thermostat failing, will investigate on the next site visit 05/13/2011 07:07 scottl@b 01:HighTemp: Noted 05/11/2011 07:02 darren@b 01:HighTemp,04:TestTagFailure: These alarms will be investigated during a site GMC today. 05/10/2011 07:32 Troy@bay 01:HighTemp: This alarms seems odd for this time of year. PSMFC will be on site tomorrow for a scheduled GMC and will investigate then. 04/21/2011 10:05 scottl Performed site GMC, all transceivers were retuned and calibrated as necessary, no problems to report. 04/13/2011 11:30 Darren A site GMC was performed today (4-13-11). All transceivers were checked and adjusted for tuning, noise and detectability as necessary. The PC clocks are within 20 seconds of atomic time and each other. The files on PC2 were archived. No problems were discovered during this visit. 04/07/2011 10:23 Roger Did GMC on 4/7/2011. Checked tuning and efficiencies on all transceivers. Adjusted as needed. No problems to report. 04/01/2011 14:55 alan@bay 03:LowExcCurrent,04:TestTagFailure: These alarms were generated by PTAGIS Field Operations personnel during a site visit. 03/31/2011 11:07 Roger Performed GMC. Checked and tuned tranceivers. No problems to report. 03/30/2011 08:01 alan@bay 04:TestTagFailure: Single alarm: 2011/03/29 14:40:50. PTAGIS Field Operations will continue to monitor. 03/16/2011 07:26 Troy@bay 04:TestTagFailure: This alarm was addressed on the last GMC, clearing TASS. 03/15/2011 11:53 scott Re tuned 0A and all of the slot transceivers. Timer tag hit rates are now at 99 to 100 percent. No other problems to report. 03/14/2011 08:17 darren@b 04:TestTagFailure: This system will be adjusted during the next site GMC. 03/13/2011 09:29 darren@b 04:TestTagFailure: This alarm will be investigated during the next site visit. 03/12/2011 07:57 darren@b 04:TestTagFailure: This system will be adjusted during the next site visit. 03/10/2011 08:04 Troy@bay 04:TestTagFailure: These alarms will be addressed on the next site visit. 03/09/2011 08:44 alan@bay 04:TestTagFailure: Most likely this is due to tuning. This will be addressed during the next site visit. 03/08/2011 07:50 alan@bay 04:TestTagFailure: This will be addressed during the next site visit. 03/03/2011 07:17 darren@b 15:LowExcCurrent,15:LowLithium,16:LowLithium: The batteries were replaced by PSMFC personnel. 03/01/2011 11:15 scottl This entry corrects the previous.Replaced the internal batteries on transcievers 15,16,04 due to low lithium alarms. No problems to report. 03/01/2011 11:14 scottl Replaced the internal batteries on transcievers 15,15,04 due to low lithium alarms. No problems to report. 03/01/2011 07:18 darren@b 15:LowExcCurrent,15:LowLithium,16:LowLithium: These alarms will be addressed during today's site GMC. 02/28/2011 07:29 Troy@bay 15:LowLithium,16:LowLithium: Noted 02/24/2011 07:24 Troy@bay 15:LowLithium,16:LowLithium: These alarms will be addressed on the next site visit. 02/23/2011 07:13 darren@b 15:LowLithium,16:LowLithium: These alarms will be addressed today. The batteries will be replaced. 02/21/2011 08:04 darren@b 15:LowLithium,16:LowLithium: These alarms will be addressed during the next site visit. 02/20/2011 07:50 darren@b 15:LowExcCurrent,15:LowLithium,16:LowLithium: These alarms will be addressed next week during a PSMFC visit. 02/19/2011 07:34 darren@b 04:TestTagFailure,15:LowLithium: These alarms will addressed next week while PSMFC is on site. 02/18/2011 07:40 alan@bay 15:LowLithium: This will be addressed during the next site visit. 02/17/2011 07:10 darren@b 15:LowExcCurrent,15:LowLithium: Battery will be replaced on the next site visit. 02/16/2011 07:14 darren@b 04:TestTagFailure,15:LowLithium: Alarms will be addressed during the next site visit. 02/15/2011 07:24 darren@b 04:TestTagFailure,15:LowLithium: Alarms on antenna 04 will be addressed during the next site visit. The battery will be replaced on transceiver 15 at the same time. 02/14/2011 07:24 darren@b 03:TestTagFailure,04:TestTagFailure,15:LowLithium: The alarms on antennas 03 and 04 will be addressed during the next site visit. The battery will be replaced on antenna 15 at that time. 02/09/2011 07:57 darren@b 03:TestTagFailure,04:TestTagFailure,15:LowLithium: These alarms will be addressed during the next site visit. 02/06/2011 06:45 alan@bay 04:TestTagFailure,15:LowLithium: These will be addressed during the next site visit. 02/05/2011 07:17 alan@bay 04:TestTagFailure,15:LowLithium: These will be addressed during the next site visit. 02/04/2011 08:19 alan@bay 15:LowLithium: This will be addressed during the next site visit. 02/03/2011 07:35 alan@bay 15:LowLithium: This will be addressed during the next site visit. 02/03/2011 07:32 Alan Centurylink reports an outage at Bonneville. ETA for internet connectivity is 9:00 today. 02/02/2011 07:14 alan@bay 15:LowLithium: This will be addressed during the next site visit. 02/01/2011 07:50 alan@bay 15:LowExcCurrent,15:LowLithium: Clearing TASS on a known problematic system. 01/30/2011 09:32 Troy@bay 04:TestTagFailure: This alarm will be addressed on the next site visit. 01/29/2011 09:17 Troy@bay 04:TestTagFailure: This alarm will be addressed on the next site visit. 01/28/2011 08:11 Troy@bay 03:TestTagFailure: This transceiver has drifted in tune and will be addressed on the next site visit. 01/27/2011 10:30 alan@bay 03:TestTagFailure,04:TestTagFailure: These alarms will be addressed during the next site visit. 01/26/2011 09:59 Troy@bay 03:TestTagFailure: Noted 01/25/2011 09:46 Troy@bay 03:TestTagFailure,04:TestTagFailure: These alarms will be addressed on the next site visit. 01/24/2011 07:25 Troy@bay 03:TestTagFailure: This transceiver alarm will be addressed on the next site visit. 01/19/2011 07:11 Troy@bay 03:TestTagFailure,04:TestTagFailure: These alarms will be addressed on the next site visit. 01/17/2011 10:41 troy@bay 03:TestTagFailure,04:TestTagFailure: These alarms will be addressed on the next site visit. 01/16/2011 08:44 Troy@bay 04:TestTagFailure: This will be addressed on the next site visit. 01/15/2011 09:01 Troy@bay 04:TestTagFailure: This transceiver appears to have drifted in tune. PSMFC will continue to monitor and address on the next site visit. 01/14/2011 09:39 Don_Warf We are currently experiencing a DSL outage at these sites. Connectivity was lost at 9:02. Centurylink reports that the outage covers the states of Oregon and Washington. They estimate the outage will last until 11:00pm tonight. More soon. 01/13/2011 07:19 alan@bay 01:TestTagFailure,04:TestTagFailure: These were addressed yesterday during a site visit. 01/12/2011 13:15 Darren A site GMC was performed today 1-12-11. All transceivers were checked and adjusted for tuning, noise, and detectability. The battery on the thermostat is low. The temp inside the PITtag room was 43 degrees and it was on a cooling cycle. No problems were discovered during this visit. 01/11/2011 07:52 Troy@bay 01:TestTagFailure,04:TestTagFailure: These alarms will be addressed tomorrow during a scheduled site visit. 01/10/2011 07:08 Troy@bay 04:TestTagFailure: A GMC is scheduled for later this week. This will be addressed at that time. 01/09/2011 08:51 alan@bay 04:TestTagFailure: This will be addressed during the next site visit. 01/08/2011 10:48 alan@bay 04:TestTagFailure: This will be addressed during the next site visit. 01/07/2011 07:39 alan@bay 01:TestTagFailure,04:TestTagFailure: This will be addressed during the next site visit. 01/06/2011 07:54 alan@bay 01:TestTagFailure,03:TestTagFailure,04:TestTagFailure: This will be addressed during the next site visit. 01/05/2011 07:22 alan@bay 01:TestTagFailure,02:TestTagFailure,03:TestTagFailure,04:TestTagFailure: This will be investigated during the next site visit. 01/04/2011 07:51 alan@bay 01:TestTagFailure,02:TestTagFailure,03:TestTagFailure,04:TestTagFailure: This will be addressed during the next site visit. 01/03/2011 07:44 alan@bay 01:TestTagFailure,02:TestTagFailure,04:TestTagFailure: These transceivers appear to have drifted slightly out of tune. This will be addressed during the next site visit. 01/02/2011 08:43 darren@b 01:TestTagFailure,03:TestTagFailure,04:TestTagFailure: These systems will be addressed during the next site visit. 01/01/2011 08:52 darren@b 02:TestTagFailure,04:TestTagFailure: These systems have drifted slightly out of tune and will be addressed during the next site visit. 01/01/2011 00:00 PTOC_Bot Annual log file initiation for BO1 #### End of Event Log for BO1 ###