EVENT LOG FOR SITE BO4 The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/04/2008 10:54 Troy A site GMC was performed 12/04/2008. All transceivers were checked for tune adjustments made where needed. No problems to report. 12/04/2008 07:28 darren@b 04:TestTagFailure: This system has drifted out of tune and will be addressed during the next site visit. 12/01/2008 07:07 scottl@b 04:TestTagFailure: Noted 11/30/2008 09:01 troy@bay 03:HighTemp,04:TestTagFailure: Unusual alarm for this time of year. This will be looked into on the next site visit. 11/28/2008 08:52 troy@bay 04:TestTagFailure: This alarm will be addressed on the next site visit. 11/27/2008 09:15 troy@bay 01:TestTagFailure,04:TestTagFailure: These alarms will be addressed on the next site visit. 11/26/2008 07:21 troy@bay 04:TestTagFailure: No obvious cause for this alarm. PSMFC will monitor. 11/25/2008 07:49 Troy Manually pushed BO408330.A1, .A2. It appears there was a DSL issue that has now been resolved. 11/24/2008 07:28 Troy PCA'ed into B04 to push the delinquent files (BO408328.G1 - BO408329.B1). Found a compressed zip file in the temp dir that I couldn't delete. Stopped Minimon briefly and still couldn't delete the file, had to shut MM down to get it to let go of the file in order to delete it. 11/22/2008 06:53 alan@bay 01:TestTagFailure: This will be investigated during the next site visit. 11/21/2008 07:19 alan@bay 01:TestTagFailure,04:TestTagFailure: Alarms will be investigated during the next site visit. 11/20/2008 07:17 alan@bay 04:TestTagFailure: No apparent reason for this one time alarm. PTAGIS Field Operations will continue to monitor. 11/14/2008 07:16 darren@b 04:TestTagFailure: No direct cause for this alarm. 11/13/2008 07:31 darren@b 04:TestTagFailure: Alarm will checked by PSMFC personnel during todays site visit. 11/12/2008 15:27 scottl At a moments notice, Embarc the DSL provider informed us that they were switching over to some new equipment that would require us to reconfigure our network with the new addressing scheme. With help from Todd, this was finished at Nov 12th at 3:15 pst. The DSL modem was also upgraded to the new 655 model at absolutely no charge to PTAGIS. The password for the Sonic Wall box in the AFF network cabinet was changed to the PTAGIS remote universal PW. Hobbit reports GREEN for the entire site, no problems to report at this time. Will monitr the network while onsite to ensure the network remains stable. 11/12/2008 07:35 darren@b 04:TestTagFailure: This alarm will be addressed during the next site visit. 11/03/2008 15:11 Dave I pcA'd into both BO4 platforms. Stopped and restarted data collection on both machines, in order to synchronize the files. I uploaded BO408307.D2-308.E2, and archived all other accumulated files on PC2. Archived BO408307.A1 on PC1. At 3PM, I again stopped and restarted data collection on both machines and uploaded BO408308.B1 from PC2, this time to synchronize file creation and upload with the PTAGIS IDL process. These actions were necessary in order to capturing and processing the files in the order they were created. I noted that the clocks on the two BO4 PCs were out of sync with each other and atomic time by slightly more than a minute, but I did not correct them. 11/03/2008 14:08 Alan Site personnel re-booted PC1 at ~13:45 PST 11-3-2008. This restored operation. The cause of the PC1 lock-up is unknown at this time. PTAGIS Field Operations will continue to investigate. The data gap will be back filled from PC2 when the exact duration of the gap is known. 11/03/2008 07:31 Scott_Li Primary PC is not sending data files and cannot be accessed remotely. Verified that data is being collected on PC2 and called the SMP office and left message requesting assistance. Will update when more information is available. 10/31/2008 11:30 Darren The UPS for PC1 was switched from a 1300 to a 1500 today at ~10:30 PST. There was a brief file gap during which time there was no PITtag detections observed on PC2. 10/31/2008 07:30 alan@bay 04:TestTagFailure: No apparent reason for this one-time alarm. PTAGIS Field Operations will continue to monitor. 10/30/2008 07:39 troy@bay 02:LowExcCurrent: This alarm generated during a site GMC. 10/25/2008 08:37 Troy Pushed BO408299.B1 to ptagis. 10/22/2008 07:46 darren@b 04:TestTagFailure: The system has slightly detuned. It will be addressed during the next site visit. 10/20/2008 08:03 troy@bay 04:TestTagFailure: Noted 10/19/2008 10:40 scottl Site is have troubles with the auto-upload process, manual uploads have been successfull. Will monitor 10/19/2008 10:33 scottl@b 04:TestTagFailure: Noted 10/18/2008 10:47 scottl Manually pushed outstanding data files with no problems 10/17/2008 07:31 scottl@b 04:TestTagFailure: Noted 10/14/2008 14:03 scottl Performed GMC, all transcievers were retuned and calibrated. There is an excessive amount of noise on all transcievers in which cannot be tuned out. This maybe due to a load on a circuit that was not being used in the past. The FDX and peak noise levels indicate this maybe the case. PIT tag reading efficiencies are not being degraded by this problem but the timertags have been. Retuned the system to the best possible and slightly turned up the TT voltage to hit 100 percent. Will monitor situation and take furhter action if necessary. 10/14/2008 07:38 darren@b 01:TestTagFailure: These systems will be addressed today during a site visit. 10/13/2008 07:16 scottl@b 01:TestTagFailure: Unit needs tuned but is still detecting PIT tags. 10/13/2008 07:15 scottl@b 01:TestTagFailure: Unit needs tuned but is still detecting PIT tags. 10/12/2008 08:05 darren@b 01:TestTagFailure: Alarm noted. System will be addressed during the next site visit. 10/11/2008 08:03 darren@b 01:TestTagFailure: The antenna has slightly detuned and will be addressed during the next site visit. 10/02/2008 07:43 troy@bay 02:TestTagFailure: Noted 10/01/2008 15:12 Darren This message was sent to PSMFC to alert of us upcoming power switches. All, On Thursday, 2 October 2008 at approximately 0100 hours we will be performing Station Service Switching. The same equipment will be effected as is listed below. 1) Outfall Building 2) Intertie Lines #1 and #2 3) Bradford Island Service Building 4) Adult Fish Facility 5) Fish View Building 6) Visitors Observation Building 7) Pit Building @ A/B Branch If you have any questions please call the control room at ext. 2221. Thanks, Brenda 09/30/2008 07:39 troy@bay 04:TestTagFailure: PSMFC will monitor for future occurances 09/29/2008 12:36 Scott_Li Per Jon Rerecich All, On Wednesday, 1 October 2008 in the early morning and again in the evening we will be performing Station Service Switching. There will be power outages to the following buildings and equipment: 1) Outfall Building 2) Intertie Lines #1 and #2 3) Bradford Island Service Building 4) Adult Fish Facility 5) Fish View Building 6) Visitors Observation Building 7) Pit Building @ A/B Branch If you have any questions please call the control room at ext. 2221. Thanks, Rob Witham 09/24/2008 07:46 alan@bay 04:TestTagFailure: No apparent reason for this one-time alarm. PTAGIS Field Operations will continue to monitor. 09/22/2008 09:12 Alan Further analysis shows that all PIT Tags were accounted for during the communication issues of 9/18 to 9/19/2008. 09/19/2008 13:14 Dave Stopped and immediately restarted data collection on BO4-PC1, in order to normalize the file creation interval to match the expected upload interval, and then manually uploaded the just-completed file BO408263.E1. 09/19/2008 10:25 Don_Warf Manually pushed the C1 file after failing to send automatically. 09/19/2008 08:14 Alan It was discovered this morning that transceiver 01 was again AWOL from PC1 but not PC2. We switched the Y-cable on the PC1 RP expansion chassis from 0 (Com4) to 8 (Com 12) and restored operations. The duration of the absent 01 data is unknown at this time. We will determine what is missing and confer with Dave to patch the data when time permits. 09/18/2008 14:27 Darren PSMFC is on site to do some cable management and may have had the network connection briefly disconnected at the time of the upload at 12:00. I manually pushed the missing files for all the sites up to PTAGIS. 09/15/2008 15:08 Scott_Li The network renovation for the entire Bonneville data collection platforms has been completed. The following lists the changes and the replacement appliances that were installed. The old Black Box network cabinet was completely tore out and replaced with a new standup Black Box cabinet that will allow easier access and more room for expansion. All new appliances were installed that includes the replacement of the Watch Guard firewall with a new Sonic Wall firewall. A new managed 24 port Dell switch and new 24 port punch down panel. All the existing FO media converters were re-used along with the FO to copper phone converter. The DSL junction box was re-routed to a new, more convenient location. All cabling and connections have been labeled and are being documented. The next phase will consist of more labeling and documentation of the fiber optic runs from the AFF PIT room to all PIT tag rooms and junctions in between. 09/15/2008 12:32 Scott_Li In response to the message brought to our attention by Dave, "Java(TM) Platform SE binary has stopped working". The offending file was Jusched.exe which is a Sun Java scheduler that runs once per month. From what I have read, by disabling the update feature for this app should eliminate the errors that were seen today on PC1 and 2. Remotely disable this feature on PC1 and 2, will monitor for reoccurring problem but this should now be a dead issue. 09/15/2008 08:10 Scott_Li The tag that was jamming the field has moved on and is no longer near the antenna. Returned the reader to Unique OFF. 09/12/2008 10:17 Dave I created and submitted a patch file, BO408249.A29, to resolve the previous omission of data from antenna 01 reported by Alan on Sept. 5. The patch file contains detection records for two fish not previously reported as detected on antenna 01. However, both tags were already reported as having been detected on all three of the other BO4 antennas. 09/12/2008 09:51 scottl@b 02:TestTagFailure: noted 09/11/2008 11:05 PTOC_Bot The network renovation for these sites has been completed. No outstanding issues exist. The SMP office has also been reconnected to the PSMFC DSL network. 09/11/2008 08:14 troy@bay 02:TestTagFailure: There is a tag in the field. 09/11/2008 07:59 troy@bay 02:LowExcCurrent,02:TestTagFailure: It is being reported that there is a tag in the field. The unique has been set to on with a delay of 30 seconds. More info will be posted when available. 09/09/2008 09:17 Troy These sites data collection has been verified while the internet connection(s) is being reconfigured. 09/09/2008 09:15 Troy It has verified that a tag is stuck in the field on 02. Unique has been turned on with a 30 second delay. 09/09/2008 08:13 Darren The noise issues on antenna 02 are being addressed by PSMFC personnel. The efficiencies have dropped and it may require that the transceiver be replaced. We will post the results of the investigation upon completion. 09/09/2008 07:11 darren@b 02:TestTagFailure: Alarm will be investigated this week by PSMFC personnel. 09/08/2008 13:38 Alan The network equipment is going to be upgraded starting today (9/8/2008) in the AFF PIT Tag room. Network connectivity for all Bonneville interrogation sites will be down for the duration of the work. The sites will continue to collect data as normal. The outstanding data files will be submitted after the upgrade is complete. The outage is expected to last no later than Thursday morning (9/11/2008). 09/06/2008 07:40 alan@bay 04:TestTagFailure: No apparent reason for this one-time alarm. PTAGIS Field Operations will continue to monitor. 09/05/2008 10:32 Alan Transceiver 01 is not communicating consistently to PC1. It is communicating consistently to PC2. PC2 was remotely set to create 3hr files and automatically submit files on a 3hr schedule. PC1's automated file uploading has been disabled. We will continue to monitor. Transceiver 01 data is most likely absent from 20:32 9/4/2008 to 06:00 9/5/2008. Transceiver 01 data will be culled from PC2 archives to fill that gap. PSMFC will be on site Monday, 9/8/2008, to remedy the situation. 09/04/2008 16:30 Alan Manually pushed BO408248.C1 to PTAGIS via RDC. 09/04/2008 11:16 scottl The Marathon interrogation platform for this site has been replaced with a standard 3 PC platform with Vista O/S and Minimon 1.5.0. The device masters have also been replaced with the standard Rocket Port panel configuration. The buffers for the 4 transcievers were dumped into interrogation file BO408248.C1 that will cover the outage while the transition was being performed. All is well but remote access via PcAnywhere will not be available until next week. In the mean time, the RDP access will be provided. No other unresolved issues to report. 08/28/2008 16:26 Scott_Li Manually pushed outstanding data file. 08/27/2008 13:04 Alan In anticipation of next weeks data collection platform renovation, I remotely changed the file extension from "1" to "0" (A1 to A0, B1 to B0, etc.) at 12:55 PDT 8/27/2008. I manually uploaded BO408240.D1 to PTAGIS. The platform is currently interrogating to BO408240.E0. 08/20/2008 09:04 Darren PSMFC received this message from Jonathan Rerecich site Biologist today. All, On Monday, 25 August 2008 in the early morning and again in the evening we will be performing Station Service Switching. There will be power outages to the following buildings and equipment: 1) Outfall Building 2) Intertie Lines #1 and #2 3) Bradford Island Service Building 4) Adult Fish Facility 5) Fish View Building 6) Visitors Observation Building 7) Pit Building @ A/B Branch If you have any questions please call the control room at ext. 2221. Thanks, Brenda 08/16/2008 08:09 alan@bay 01:HighTemp,03:HighTemp,03:LowExcCurrent,04:HighTemp: Noted. 08/13/2008 08:52 alan@bay 02:TestTagFailure: This alarm was generated by PTAGIS Field Operations personnel during a site visit. 08/12/2008 13:32 scottl All transcevers were tuned and calibrated as necessary, one note is that units 01,02,03 noise levels are at 0 percent and 04 is at 0 to 3 percent and could not be tuned out. This should be investigated further when time permits. No other problems to report. 08/11/2008 16:29 Mail_Bot I removed tag 3E7.000001D004 from the list of timer tags, but left it in the list of test tags. 08/08/2008 08:30 darren@b 04:TestTagFailure: Alarm will be addressed during the next site GMC. 08/03/2008 10:03 Troy Finally got back into the vft and stopped minimon, when I tried to start minimon again, I received a message that minimon was already running. With Scott's help I restarted the vft. When I logged back in everything appeared to be running ok. I pushed 2 files to ptagis BO408215.B1 and BO408215.C1, the .C1 file being one large file. Hopefully restarting the vft fleshed out any problems that might have been present. 08/03/2008 09:41 Troy This site is up but has issues. I was kicked out of my first RDP, will attempt again. It appears the site is building one big file. More when available. 07/29/2008 13:15 Darren The preliminary field testing for the DF model 2020 transceiver was completed on the large slot antennas today. The transceiver was removed from antenna 02 at 12:58 PDT with the last of the detections placed in file BO408211.D1. The FS 1001B was placed back into its original position on antenna 02 and the entire sight was retuned. 07/26/2008 09:04 Troy 01 and 02 were at 90 on today's CEA report. This may be due to temperature, water level or fish grouping. PSMFC will monitor and address the situation if it worstens. 07/24/2008 08:36 Darren A site GMC was performed yesterday (7-23-08). All the transceivers were checked for tuning, noise, and detection ability. Alex Artyukhov of Destron Fearing assisted in the tuning of the model 2020 that is currently installed on antenna 02. He felt that the system had not drifted in tune. PSMFC is monitoring the daily efficiencies of this system for reporting purposes. The system has been running very affectively since installed. 07/16/2008 08:46 Darren On 7-15-08 at 12:00(pst) the Destron-fearing model 2020 transceivers was installed on antenna 02. The system was tuned by Alex Artyukhov of Destron-Fearing and will be left in place for the next few weeks to evaluate the performance on the large size slot antenna. Currently the reader will only send tag information to the computer platform so we will not see any timer tag information for this system while this reader is in place. The rest of the transceivers were tuned and no interaction between existing systems ond the new reader were visible. PSMFC will tracking the efficiencies of this reader compared to the exisiting system while it is installed. 07/15/2008 08:19 alan@bay 03:HighTemp: This alarm is normal for this time of year. 07/13/2008 07:26 darren@b 03:HighTemp: This alarm is to be expected this time of year. PSMFC will monitor this system for performance. 07/12/2008 13:00 Darren PSMFC noticed this morning that communications to the device master for antennas 03 and 04 were not present since yesterday around 10:00 yesterday. Numerous attempts were made to remotely solve this issue but it could ot be persormed. Once on site it appeared that the network cable for the device master was not working. A jumper was run between the device master and a wall ehternet port to restore communications to the platform. PSMFC will be on site on Tuesday to make the connection more permenant. Minimon was stopped and restarted and the transceiver communications was tested. 07/09/2008 08:18 darren@b 03:TestTagFailure: Problem was addressed yesterday by PSMFC personnel during a site GMC. 07/08/2008 13:20 scott Performed GMC, all transceivers were retuned and adjusted as necessary. TT voltage on 03 was set too 30 percent hit rate. tuned transciever and adjusted TT voltage to correct the situation. No problems to report. PC clock was set to within the 1 min. window of atomic time. 07/08/2008 08:29 darren@b 03:TestTagFailure: This alarm is caused by a slight drift in tune of the detection system. PSMFC personnel will be on site today to perform a site GMC which will alleviate this condition. 07/07/2008 08:18 darren@b 03:TestTagFailure: This alarm will be addressed during the site GMC tomorrow by PSMFC personnel. 07/06/2008 09:36 troy@bay 03:TestTagFailure,04:TestTagFailure: The TT will be adjusted on the next site visit. These transceivers are reading fish at a high efficiency. 07/05/2008 10:28 troy@bay 03:TestTagFailure: This will be addressed on the next site visit. 07/04/2008 08:13 troy@bay 03:TestTagFailure: This issue has been well documented, clearing TASS. 07/03/2008 08:11 troy@bay 03:TestTagFailure: This transceiver is still reading fish at a high efficiency. The TT and tune will be addressed on the next site visit. 07/02/2008 07:42 troy@bay 03:TestTagFailure: This transceiver is still in the 90's in fish efficiencies. This will be addressed on the next site visit. 07/01/2008 08:46 troy@bay 03:TestTagFailure: PSMFC is aware of the problem and will address it on the next site visit. This transceiver is still reading fish at a high percentage 06/30/2008 08:35 troy@bay 03:TestTagFailure: This alarm will be addressed on the next site visit. The transceiver is currently reading fish at 97.10% 06/29/2008 09:17 scottl@b 03:HighTemp,03:TestTagFailure: Unit is detuned and phase is shifted. Timer tags is not firing but the unit is still detecting fish at 92 %. 06/26/2008 08:00 scottl@b 03:TestTagFailure: Noted. 06/25/2008 08:03 darren@b 03:TestTagFailure: No direct cause for this alarm. We will continue to monitor for future alarms. 06/24/2008 14:11 Alan The transceivers were checked and tuned as necessary 6/24/2008. Transceiver 01 had drifted up to 52%. All transceivers (including 03) are behaving well. No problems found. 06/23/2008 08:36 Darren PSMFC was onsite Friday (6-20-08) to adjust the slot antennas and full flow system due to the lowered efficiencies noticed on Thursday (6-19- 08). PSMFC also investigated the unusual noise that has been noticed on the slot antennas at BO4. PSMFC contacted Mary Moser (NOAA Fisheries) to test the HDX system to ensure that it was not the cause of the noise. The system was turned OFF and ON and there was no change in the noise spikes rolling through the 4 transceivers. A noise block filter was placed in line with the transcievers to check for possible feedback on the AC system but still no change. PSMFC also looked at the noise spectrum with a spectrum analyzer but did not detect any outside frequencies between 10kHz and 500kHz. This problem will continue to be investigated until a solution can be found. The efficiencies are still in the high 90% range for system as a whole. 06/22/2008 07:45 alan@bay 03:TestTagFailure: This will be investigated during the next site visit. 06/18/2008 12:57 Troy At the site to determine what may be causing 03 to have lower than normal efficiencies. All the grounds where checked, no affect. The Cap housing was inspected, no problems seen. A different transceiver was install and still 03 is noisier than the rest. It should be noted that there is a slight amount of noise going through the system that cannot be tuned out. There is also a high amount of pit tagged fish going through the system which makes tuning a bit of a challeng. PSMFC will discuss further trouble shooting approaches. The orginal transceiver was put back in and the spare returned to the pit tag room in the AFF. No other problems to report. 06/17/2008 14:22 scottl The switch over to the new ISP is complete. All internal DNS entries are now pointing to the new server. Did a diagnositc test upload on all computers without errors. B2J FF system is experiencing some noise in all transcievers that cannot be tuned out, especially 04. This phenom in the past has been associated with grounding but never been proven. BO4 also has intermittent and sometime persistent elevated noise levels that also cannot be tuned out. Will talk it over and get a game plan to correct the situations or atl east minimize the effects. 06/16/2008 10:55 Darren After checking reports it appears that the efficiencies on antenna 03 have fallen. PSMFC will be on site tomorrow for a site GMC and this issue will be addressed during that period of time. 06/12/2008 12:35 Troy A site GMC was performed 06/12/2008. All transceivers were tuned. 03 and 04 have a slight amount of noise (jumps to 2-4 at times). No other problems to report. 06/11/2008 13:42 Alan Manually pushed BO408163.D1 to PTAGIS via PCA. 06/04/2008 12:42 Alan A GMC was performed 6/4/2008. All transceivers were checked and tuned as necessary. The clock on the Ftv (~00:01:00 fast) was adjusted to within one second of atomic time. No problems found. 05/30/2008 07:31 darren@r 04:TestTagFailure: Alarms were addressed during a site GMC. 05/29/2008 13:24 Darren A site GMC was performed today (5-29-08). The transceivers were tuned via the SOP for FS 1001B type transceivers. It appeared that they had drifted since the last GMC visit. The detection systems appear to have a little noise passing through the system with system 03 being the most affected. I was unable to directly find the cause of this noise but I was able to optimize the detection ability on all four antennas. No other problems were discovered during this visit. 05/20/2008 13:09 scottl Performed site GMC, all transceivers were tuned and TT hits rates verified at 100 percent. When arrived in the BO4 PIT room, the FTV was not available but data was being collected and file being submitted. Without other recourse, restarted the FTV and still have the same problem. When trying to access the FTV, the error "BitBit handle is invalid" The error is a known problem by Marathon and could have probably been corrected in susequent OS releases. Restarted the entire Endurance configuration and corrected the situation. The system was offline for ~ 5 minutes during the restart. Verified data collection and all is again well. 05/18/2008 14:41 scottl Followed up to ensure that the site loaded due to previous activities. No problems to report. 05/18/2008 10:51 Alan Noting that the site missed the 3:00:00 file load, I attempted to RDP into the Ftv to verify the site as operational. Short story long, the usual method to RDP into that computer created multiple instances of Minimon running simultaneously. Scott was able to log in the the Ftv sucessfully and verified functionality. During this process, the Ftv was rebooted twice, creating small data gaps. PTAGIS Field Operations will continue to monitor. 05/18/2008 10:01 alan@ree 04:TestTagFailure: Noted 05/14/2008 08:35 alan@ruf 04:TestTagFailure: No apparent reason for this alarm. PTAGIS Field Operations will continue to monitor. 05/13/2008 13:27 Darren A GMC was performed today (5-13-08). All transceivers were checked for tuning, noise, and detection ability. No problems were discovered during this visit. 05/07/2008 08:15 troy@ruf 03:LowExcCurrent: This alarm was generated during a GMC. 05/06/2008 13:09 scottl Performed site GMC, all transicevers where checked for proper tune and TT hit rates as necessary. In order to prevent further condensation in the power distribution enclosure,(or an attempt to) a small weep hole was drilled into the bottom to allow for drainage. Maybe to little to late, the terminal lugs are severely corroded on most of the ground leads and others. This panel should be revisited when the time permits. All connection should be cleaned and tightend, and some terminal blocks may require to be replaced. 05/05/2008 08:25 troy@ruf 01:TestTagFailure: Noted 05/03/2008 10:10 Scott_Li Timer tags on transceivers 01 and 04 respectively are struggling abit, efficiencies are slightly low. Will monitor and correct on Tuesday the 5/6. 05/03/2008 09:48 scottl@r 04:TestTagFailure: Problem noted 05/01/2008 08:01 scottl@r 03:LowExcCurrent: Alarm created during the GMC, not a problem. 04/30/2008 13:03 Darren A site GMC was performed today (4-30-08). All transcievers were checked for tuning, noise and detection ability. Transceiver 03 is noisy (6-8% on the signal) so I spent most of my time adjsuting the tune to achieve the best hit rate at the lowest voltage I could obtain. I also inspected the surrounding area for potential interference but could not locate anything that has not been at this location for the last couple of years. PSMFC will monitor these changes to see the effect. No other problems were discovered during this visit. 04/24/2008 13:39 Alan A GMC was performed 4/24/2008. All transceivers were checked and tuned as necessary. The clock on the Ftv is 23 seconds ahead of atomic time. No problems found. 04/10/2008 15:33 scottl For clarification, transcievers 03 and 04 continued to collect data during the time that 01 and 02 were not communicating with the platform. 04/10/2008 15:28 scottl Sometime yesterday or there about, comms from transceiver units 01 and 02 was lost. Traveled to the site and found that the network cable from Device Master serviceing 01 and 02 was bad. Rerouted new cable back to the network cabinet and comms were restored. No other problems to report. 04/09/2008 12:47 Troy A GMC was performed 04/09/2008. All transceivers were checked for tune, 03 and 04 are a little noisy(6-10%) but reading 100% on the TT test. No other problems to report. 04/04/2008 08:35 darren@r 03:LowExcCurrent: Alarms were generated by PSMFC personnel while performing maintenance on the site. 04/03/2008 13:41 Alan A GMC was performed 4/3/2008. All transceivers were checked and tuned as necessary. All transceiver CPU Batteries were changed. The Ftv is eight seconds ahead of atomic time, no problems found. 03/24/2008 12:19 Alan A GMC was performed 3/24/2008. All transceivers were tuned. The clock on the Ftv (about a minute fast) was set to within one second of atomic time. No problems found. 03/22/2008 10:00 alan@ruf 02:TestTagFailure: This one time alarm occurred simultaneous with a reader reset. 03/12/2008 14:53 scottl Performed site GMC, all xcvrs were retuned and calibrated as necessary. BO3 PC clocks are within 36 sec. of each other and 13 sec. ahead of atomic time. UPS's were replaced with the new RS-1300s. 02/27/2008 07:22 Troy A site GMC was performed 0/26/2008. All transceivers were checked for tune and adjustments made where needed. 02/04/2008 07:26 darren@r 03:TestTagFailure: This alarm will be addressed during the next site visit. 01/17/2008 10:40 Dave Jon Rericich (Corps) reported today that there was a partial, emergency dewatering of the BON Washington Shore ladder on Monday (Jan. 15) between 1800 and 2000h. 01/15/2008 07:03 troy@ruf 01:TestTagFailure: Noted 01/08/2008 11:56 Darren A site GMC was performed today 1-8-08. All transceivers were checked and adjusted for tuning, noise, and detection ability. No problems were found. 01/03/2008 07:30 darren@r 04:TestTagFailure: This alarm will be investigated on the next site visit. 01/02/2008 09:38 Alan Manually submitted BO407355.B9 to PTAGIS via RDC. It was created from BO407355.B1.TMP to help fill the data gap of 12/21/2007. No further data exist to fill the remaining gap. 01/01/2008 10:01 troy 04:TestTagFailure: Noted 01/01/2008 00:00 PTOC_Bot Annual log file initiation for BO4 #### End of Event Log for BO4 ###