EVENT LOG FOR SITE 9_GRA Most recent activity to be listed first. First line of each entry lists date, time & who is reporting. Subsequent lines of each entry aligned under Time column. Date Time Who What -------- ----- -------- ----------------------------------------------- 12/12/96 16:12 dlwarf Site personnel report that the trap was shut down for the season this morning at 8:00am. 12/10/96 07:00 scottl Tha last successful interrogation load was on 12/7/96. Problem is being determined and will be back on line when resolved. 11/12/96 11:43 dlwarf Contacted USwest about noise on the data line causing upload problems. Service was scheduled for today. 11/08/96 08:40 jen download failed again last night, this time with a file transfer error. i manually downloaded the files this morning. will continue to monitor situation. 11/07/96 09:43 jen manually downloaded last couple of days of data from gra just alittle while ago. there is either a problem with the outgoing modem, the modem at gra, or phone line garbage due to moisture. our nightly downloads are failing due to phone line errs. there was only one fish detected in the day 311 file, so the files will be processed tonight. 11/05/96 13:23 scottl There was no upload for this facility from 10/2/96 to 10/5/96. Files where manually uploaded by Jen in gladstone around 1100 hrs on 10/5/96. Appearent cause for the delay was the modem in the pc was locked up. This should not have disrupted data collect, just a delay in getting the data. 09/04/96 07:44 scottl The old efficiency reports indicated probelms with coil 06,08 ( eastflume). Observed very low water flows thru the flume. Stick test confirmed low efficiency. NMFS site personell cleaned screens in order to increase flows thru the flume. Checked and retuned entire east flume monitors. Ran stick test again. Coils 06,08 detected 10 of 13 stick tags while 00,02,04, detected 13 of 13. Replaced exciter for coils 06,08 due to poor connections and low reads. Could not re-test due to no Site personell to facilitate the stick tag test. Wll monitor for improvement. Stick tag test for the west flume results as follows: coil 10 detected 13 of 13. 12 13 of 13 14 13 of 13 16 13 of 13 18 13 of 13. 07/31/96 10:09 dlwarf General maintenance check found no problems. 07/17/96 08:34 dlwarf General maint check found no problems. 07/03/96 08:17 scottl General maintenence check found no problems. 06/26/96 08:31 dlwarf Ran a general maintenance check. Site is not using enough water to run stick tests. Could not check exciter amperages due to water leaks in front of boxes. Looked for other areas to mount exciter boxes. 06/21/96 01:20 jen don warf requested i manually download from gra as the phone line problem was resolved today (uswest gave no reason for the line being down and how they fixed it). i manually downloaded files and they are now loading into ptagis. 06/20/96 16:34 dlwarf Data line at site is still having problems. US West is giving us no information on what is the problem or when it will be fixed. 06/20/96 08:15 jen load from gra failed this morning. i just called and got an answer by phone, but when i try to call by modem i get no carrier. it appears that the site can receive calls but cannot send yet again! 06/19/96 15:17 scottl Talked with the US West technician today at the site regarding the ongoing problems with the phone line for the data collection pc. I had asked him what alternatives we have in order to eliminate frequent downtime of this line. He had no real answers but had several excuses. Switching to the Colfax trunk line is not an option because there is no free pairs left in the line. The problem with the line we have now, according to US West is that the phone numbers are grouped into 8 lines and radio transmitted to a repeater station and is succeptable to interference and other natural causes. We will continue to look for alternatives to resolve this problem or to at least minimize it. 06/18/96 13:38 dlwarf Contacted US West about the data phone line problems. They will have a technician there tomorrow between 8:00am and 11:00am. 06/17/96 21:03 scottl PSMFC will call US West again to report phone line problems on 6/18/96. See below entry for todays events. I Also noticed that the water in the East flume has increased some and may need to be re-tuned. Will monitor efficiencies and check tune on tunnels at the next general maintenence visit. 06/17/96 01:50 jen scott called from granite adult facility and we tested the phone lines from here to there. apparently you can call in but cannot call out on the line. scott switched phone lines so i could download the last few days data to our server, currently that data is being uploaded into the PTAGIS database. 06/17/96 08:55 scottl The interrogation load summary indicated that the collection computer did not upload again last night. Called the modem to verify proper operation. Will try and contact someone at the site to reboot the computer and try the upload process again. As of 0845, no one was available at site. 06/16/96 10:37 scottl The data collection computer did not upload last night for unknown reasons. Called Ken at the site to verify that the phone line had dial tone and it did. Also had Ken verify that the modem was awaiting an incoming and it was. It looks as if the connection may have been prematurely disconnected before the upload process was complete. Will follow up on this on monday 6/17/96 if the upload process fails again tonight. 06/13/96 08:07 dlwarf Contacted US West about the numerous phone outages at the site. After talking with serveral differant people at differant levels, no solution was offered and no complaint avenue is available. 06/11/96 15:43 scottl The Data line for this site has been repaired. Called modem to verify proper operation. 06/10/96 15:43 scottl Called us west again to follow up on reported phone line problem. The line was apparently repaired on or around 6/6/96, but went down again soon after. US West has been notified again and will send repair crew out to fix the problem. Don suggested to US West that we would like this line switched to a different trunk line to eliminate frequent failures. Will monitor US West's progress to ensure a speedy repair. 06/05/96 16:30 scottl Visited site for general maintenence check. Phone line is still down. Will call US west and follow up on repair progress. Down loaded interrogation files using a different phone line. No other problems found. 06/05/96 15:07 dlwarf Site phone line is still dead. Called US West again. A service rep will be on it again tomorrow. 06/05/96 11:05 jen manually downloaded 27 interrogation files from GRA. scott used another phone line as the original line is still down. the data from those 27 files are currently being loaded into PTAGIS. 06/04/96 16:11 dlwarf Phone line is still down at site. US West is working on the problem and estimate service being restored by noon tomorrow. 06/03/96 11:58 dlwarf Contacted Loren Jensen at Lower Granite about the dead phone line for the Adult data collection computer. He called back to say that they had checked out their end and found out the in comming line was dead. I then called U.S. West who reported a downed cable, in the area, and already have personel on the problem. It was estimated to be repaired by noon today. 06/02/96 08:33 scottl The phone line for gra is down. Talked with Ken on the phone to verify. He indicated that the main computer may have not been collecting data. Rather than take a chance, Traveled to site to verify proper operation of collection pc. Ran Scandisk on pc and corrected disk problems. Traced phone line back to the wall jack and checked all connections in between. Problem up there with the phone line seems to intermittent. It is suggested that we replace the the line within the office to eliminate several connections. Will contact the long distance carrier and report problem. General maintenence check found no problems. 05/21/96 07:59 scottl General maintenence check found no problems.. 05/15/96 09:14 scottl Visited site on 4/13 to address maintenence issues regarding relocation of electronics, accessability to coils and the lack of water through the tunnels. Stick tests at this site are very difficult due to the sticks hanging up in the flumes and retrieval of the sticks. General maintenence check found no problems. 05/14/96 07:35 scottl General maintenence check found no problems. 05/08/96 07:46 scottl Repaired tuner connector at exciter for coil 04. timer tags fired consistently. Stick test at the adult trap are not very feasable at this time due to the low amount of water running through the flume. Sticks get caught in the tunnels and are difficult to get out. All timer timer tags fired ok.. No other problems found. 05/06/96 13:17 scottl Timer tag problems will be corrected on the next routine maintenence visit. At least on timer tag code was seen on each coil indicating that the coils are still alive. 05/03/96 15:10 dlwarf Visited for maintenance check. Everything looks ok. 04/30/96 09:05 scottl Main computer was locked up. Called Ken McEntire and he rebooted PC. Up-load for 4/30 was successful. No pittag fish were seen during the time computer was down as verified by printer hardcopy. 04/22/96 09:04 scottl Pre season tuning and testing has been completed as of 4/20/96. 03/29/96 16:00 carters Electrical conduit has been repaired. Due to water-up trap on April 15. 03/28/96 15:45 carters The interrogation system at the Lower Granite ladder adult trap was connected yesterday after site modifications made by COE and NMFS were completed. It is not known at this time whether or not the trap is in operation, however. Fixed reference tags are being operated in order to assure that the PIT interrogation system is operating normally. 03/12/96 16:56 carters Initial log creation for 9_GRA ####End of Event Log for 9_GRA###