EVENT LOG FOR SITE GRA The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/29/2006 11:00 Don_Warf Per Pete Peterson: These sites are unreachable due to a MCI cable cut. Crews have been dispatched. Estimated to be repaired later today. -----Original Message----- From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Friday, December 29, 2006 9:15 AM To: sitemaint@psmfc.org Subject: Problems with remote data sites... The following problems with remote sites were detected; gra: Last data submission was received on Fri Dec 29 6:03:14 PST 2006 mc2: Last data submission was received on Fri Dec 29 6:01:40 PST 2006 Please check this out. 12/21/2006 07:41 alan@ree 01:ReaderReset,01:TestTagFailure,02:LowExcCurrent,02:ReaderReset,02:Rocket PortNoEOT,03:ReaderReset,04:LowExcCurrent,04:ReaderReset,05:ReaderReset,06 :LowExcCurrent,06:ReaderReset,07:ReaderReset,08:ReaderReset: These alarms were caused by PTAGIS Field Operations personnel during a site visit. 12/20/2006 07:20 darren@r 01:ReaderReset,02:ReaderReset,02:RocketPortNoEOT,03:ReaderReset,04:ReaderR eset,05:ReaderReset,06:ReaderReset,07:ReaderReset,08:ReaderReset,12:Reader Reset,14:InputSyncDetect,14:InputSyncLost,14:ReaderReset,16:InputSyncDetec t,16:ReaderReset,18:ReaderReset,22:InputSyncDetect,22:ReaderReset,24:Input SyncDetect,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:ReaderReset : These alarms appear to be generated by a power outage. 12/14/2006 07:16 scottl@r 02:Overrun,26:InputSyncDetect,26:ReaderReset: Problem noted, will monitor and correct if and when necessary 12/12/2006 07:16 troy@ree 02:Overrun: This alarm will be looked into on the next site visit. 12/11/2006 07:28 scottl@r 02:Overrun: System was tuned on 12/7/06. Will revisit on the next GMC 12/10/2006 08:56 darren@r 02:Overrun: Alarms will be addressed on the next site visit. 12/09/2006 07:57 darren@r 02:Overrun: This alarm will be addressed next while PSMFC is on site. 12/08/2006 11:51 dlwarf@r 01:ReaderReset,02:LowExcCurrent,02:Overrun,02:ReaderReset,03:ReaderReset,0 4:ReaderReset,05:ReaderReset,06:ReaderReset,06:RocketPortNoEOT,07:ReaderRe set,07:RocketPortNoEOT,08:ReaderReset,12:ReaderReset,14:InputSyncDetect,14 :ReaderReset,16:InputSyncDetect,16:ReaderReset,18:ReaderReset,22:InputSync Detect,22:ReaderReset,24:InputSyncDetect,24:ReaderReset,26:InputSyncDetect ,26:ReaderReset,28:ReaderReset: Power outage. 12/07/2006 10:25 Alan A GMC was performed 12/7/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs were set to within one second of atomic time, no problems found. 12/07/2006 07:57 troy@ree 02:Overrun,06:RocketPortNoEOT: These alarms appear to be the result of several power outages that occured from 13:02 to 13:28 on 12/6/06. 12/07/2006 07:47 troy@ree 01:ReaderReset,02:ReaderReset,03:ReaderReset,04:ReaderReset,05:ReaderReset ,06:ReaderReset,07:ReaderReset,08:ReaderReset,12:ReaderReset,14:InputSyncD etect,14:ReaderReset,16:InputSyncDetect,16:ReaderReset,18:ReaderReset,22:I nputSyncDetect,22:ReaderReset,24:InputSyncDetect,24:ReaderReset,26:InputSy ncDetect,26:ReaderReset,28:ReaderReset: These alarms are most likely the result of a power outage. This will be verified later today. 12/06/2006 07:38 darren@r 02:Overrun: Alarms will be addressed tomorrow during a site GMC. 12/02/2006 11:08 troy@ree 04:BadExcFreq: This alarm will be looked into on the next site visit. 12/01/2006 07:44 troy@ree 04:BadOscFreq: Noted 11/30/2006 10:15 Alan Manually fired timer tag vis PCA 11/30/2006 ~07:10:00 11/25/2006 10:28 alan@ree 14:InputSyncDetect,14:ReaderReset: Random reader reset. PSMFC and DA are aware of the problem. 11/21/2006 13:48 Don_Warf Site personnel report that the trap gate was closed today at 10:45. Dewatering will take place tomorrow morning. The trap will be down until March 1st, 2007. Remodeling of the trap will start on 11/27. No word yet as to when the ladder will dewater. 11/21/2006 12:03 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/11/21 11:13:57 11/21/2006 12:03 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/11/21 11:13:56 11/21/2006 12:03 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/11/21 11:13:54 11/21/2006 12:03 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/11/21 10:42:32 11/16/2006 13:26 Alan A GMC was performed 11/16/2006. All transceivers were checked and tuned as necessary. PC1 is one second ahead of atomic time. PC2 is 11 seconds behind atomic time. No problems found. 11/13/2006 09:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/13 06:47:46 11/13/2006 09:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/13 06:47:45 11/13/2006 09:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/13 06:47:12 11/13/2006 09:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/13 06:47:11 11/13/2006 09:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/13 06:33:50 11/13/2006 09:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/13 06:33:49 11/13/2006 06:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/13 04:45:13 11/13/2006 06:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/13 04:45:13 11/13/2006 06:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/13 04:16:29 11/13/2006 06:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/13 04:16:29 11/13/2006 06:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/13 04:16:28 11/13/2006 06:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/13 04:16:28 11/09/2006 09:42 Dave Power outages at LGR yesterday resulted in the truncation of GRA and GRJ data files. I have programmatically "CLOSED" those files. I can't tell from the data files if PIT tag detection capability was affected during the intervals between the loss of power at the computer and the eventual expiration of battery power from the UPS. 11/09/2006 07:24 darren@r 01:LowExcCurrent,01:ReaderReset,02:ReaderReset,03:ReaderReset,04:ReaderRes et,05:ReaderReset,06:LowExcCurrent,06:ReaderReset,07:LowExcCurrent,07:Read erReset,08:ReaderReset,12:ReaderReset,14:InputSyncDetect,14:ReaderReset,16 :InputSyncDetect,16:ReaderReset,18:ReaderReset,22:InputSyncDetect,22:Reade rReset,24:InputSyncDetect,24:ReaderReset,26:InputSyncDetect,26:ReaderReset ,28:ReaderReset: Unscheduled power outage. 11/09/2006 07:24 scottl@r 01:LowExcCurrent,01:ReaderReset,02:ReaderReset,03:ReaderReset,04:ReaderRes et,05:ReaderReset,06:LowExcCurrent,06:ReaderReset,07:LowExcCurrent,07:Read erReset,08:ReaderReset,12:ReaderReset,14:InputSyncDetect,14:ReaderReset,16 :InputSyncDetect,16:ReaderReset,18:ReaderReset,22:InputSyncDetect,22:Reade rReset,24:InputSyncDetect,24:ReaderReset,26:InputSyncDetect,26:ReaderReset ,28:ReaderReset: Alarms caused by temporary power outage. Info pulled from the PLC values: 2006/11/08 13:11:13 --> set to 'ON' 2006/11/08 12:54:03 --> set to 'OFF' Unclear as to the cause of the outage 11/08/2006 22:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 20:09:14 11/08/2006 22:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 20:09:13 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 16:18:56 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 16:18:51 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 16:14:53 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 16:14:51 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 16:14:33 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 16:14:32 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 16:12:21 11/08/2006 19:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 16:12:20 11/08/2006 16:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 13:49:28 11/08/2006 16:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 13:49:27 11/08/2006 16:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/11/08 13:11:23 11/08/2006 16:02 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/11/08 13:11:23 11/08/2006 16:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 13:11:23 11/08/2006 16:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/11/08 12:53:57 11/08/2006 16:02 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/11/08 12:53:57 11/08/2006 16:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 12:53:56 11/08/2006 16:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/11/08 12:46:14 11/08/2006 16:02 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/11/08 12:46:14 11/08/2006 16:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/08 12:46:14 11/08/2006 16:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/11/08 12:15:13 11/08/2006 16:02 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/11/08 12:15:13 11/08/2006 16:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/08 12:15:12 11/08/2006 15:53 Don_Warf An unplanned power outage was reported by site personnel from 12:10 to 13:30. 11/06/2006 08:55 Dave An extended power outage on Nov. 4 caused the MultiMon program to terminate abruptly. The power outage began at 9:46AM. Although the MultiMon computers are wired through an uninteruptible power supply (UPS), the UPS batteries died (as expected) after 45 minutes, at around 10:30AM. Power was not restored to the facility until 11:27AM. Although the computers were off-line for only 57 minutes, the facility was without power for about 100 minutes. No PIT-tagged fish passing through any of the PIT tag antennas during that 100-minute interval would have been detected. 11/05/2006 17:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/05 14:17:06 11/05/2006 17:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/05 14:17:05 11/05/2006 17:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/05 13:35:28 11/05/2006 17:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/05 13:35:27 11/05/2006 14:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/11/05 11:27:43 11/05/2006 14:02 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/11/05 11:27:43 11/05/2006 14:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/11/05 11:27:43 11/05/2006 14:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/11/05 09:46:12 11/05/2006 14:02 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/11/05 09:46:12 11/05/2006 14:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/11/05 09:46:11 11/04/2006 08:26 Alan_Bro Sites have been verified online, will monitor for 9:00 load. ________________________________ From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Sat 11/4/2006 6:15 AM To: sitemaint@psmfc.org Subject: Problems with remote data sites... The following problems with remote sites were detected; ich: Last data submission was received on Sat Nov 4 3:01:25 PST 2006 gra: Last data submission was received on Sat Nov 4 3:02:31 PST 2006 Please check this out. 10/31/2006 07:53 alan@ruf 02:LowExcCurrent: This alarm was generated by PTAGIS Field Operations personnel during a site visit. 10/30/2006 14:17 Alan A GMC was performed 10/30/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs were set to within one second of atomic time. No activity was observed on PC2 during PC1's downtime. No problems found. 10/30/2006 10:01 Scott_Li Multimon was stopped and restarted to circumvent to DST Phenom in the OS. 10/25/2006 08:08 Alan_Bro This is being reposted as the original posting yesterday didn't make it to the event logs: All primary data collection computers auto upload functions were re-engaged at 12:43 PST. Delinquent files were not manually pushed to PTAGIS. The uploader will submit files in the next 3 hrs. 10/24/2006 18:08 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/24 13:22:05 10/24/2006 18:08 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/24 13:22:04 10/24/2006 15:07 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/24 09:04:03 10/24/2006 15:07 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/24 09:04:02 10/24/2006 09:45 Alan_Bro Automated file loading has been disabled. 10/17/2006 19:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/17 16:55:01 10/17/2006 19:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/17 16:55:01 10/17/2006 04:08 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/17 01:57:41 10/17/2006 04:08 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/17 01:57:40 10/16/2006 01:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/15 22:50:51 10/16/2006 01:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/15 22:50:51 10/15/2006 22:10 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/15 20:49:53 10/15/2006 22:10 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/15 20:49:52 10/15/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/15 07:51:15 10/15/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/15 07:51:15 10/14/2006 08:34 darren@r 01:ReaderReset,03:LowExcCurrent,03:ReaderReset,04:ReaderReset,05:ReaderRes et,06:ReaderReset,07:ReaderReset,08:ReaderReset: These alarms were generated by a brief power outage with the exception of the "LowExcCurrent" on antenna 03. There was no direct cause for this alarm. PSMFC wil continue to monitor. 10/14/2006 04:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/14 02:47:02 10/14/2006 04:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/14 02:47:03 10/14/2006 01:10 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/10/13 21:25:21 10/14/2006 01:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/10/13 21:25:22 09/29/2006 10:08 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/29 08:12:40 09/29/2006 10:08 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/29 08:12:26 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/25 14:02:40 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/25 14:02:38 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/25 14:02:21 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/25 14:02:19 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/25 14:00:02 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/25 14:00:00 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/25 13:59:49 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/25 13:59:48 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/25 13:59:34 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/25 13:59:33 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/25 13:54:00 09/25/2006 16:09 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/25 13:53:58 09/25/2006 16:09 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/09/25 13:53:02 09/25/2006 16:09 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/09/25 13:52:58 09/18/2006 10:06 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/09/18 08:04:25 09/18/2006 10:06 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/09/18 08:04:24 09/13/2006 15:33 Dave Received a request from Jerry Harmon to decrease the delay before activating the trap gates; fish were striking the apex of the flume separator walls as the gate was opening. Decreased the delay on all SxC antennas to 1 msec in map file GRA06256.MAP, and installed the map file on both computers. Reset the default PTTP action from "Upload and archive" to "Archive only" on GRA-PC2. (This is necessary to prevent the possible uploading and instantiation of redundant, but not duplicate, detection data, diagnostic messages, and alarms to the PTAGIS database and file servers.) Reset the PC clocks to within 1 second of atomic time and each other. 09/12/2006 15:42 Scott_Li PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Sep 12, 2006 12:00:00 09/11/06 GRA Coil 12 10 tags 11 hits 09/11/06 GRA Coil 14 10 tags 10 hits 09/11/06 GRA Coil 16 10 tags 10 hits 09/11/06 GRA Coil 18 10 tags 11 hits 09/11/06 GRA Coil 22 10 tags 11 hits 09/11/06 GRA Coil 24 10 tags 10 hits 09/11/06 GRA Coil 26 10 tags 10 hits 09/11/06 GRA Coil 28 10 tags 11 hits First Stick: 11-sep-2006 09:54:47 First File: GRA06254.104 Last Stick: 11-sep-2006 12:22:48 Last File: GRA06254.105 GRA 09/11/06 Total: 184 Ken Thomas weekly stick test report, No problems found 09/12/2006 08:15 scottl@r 06:LowExcCurrent,06:ReaderReset,07:LowExcCurrent,07:ReaderReset,07:TestTag Failure,08:ReaderReset,08:RocketPortNoEOT: Error were generated by PSMFC while performing a GMC 09/12/2006 07:06 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/09/12 04:52:17 09/12/2006 07:06 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/09/12 04:52:16 09/11/2006 16:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/09/11 12:20:39 09/11/2006 16:04 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/09/11 12:19:51 09/11/2006 16:04 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/11 12:18:26 09/11/2006 16:04 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/11 12:17:36 09/11/2006 08:30 alan@ruf 22:InputSyncDetect,22:ReaderReset: Random reader reset, PSMFC and DA are aware of the problem. 09/07/2006 11:37 Alan A GMC was performed 9/6/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs were set to within one second of atomic time. File GRA06249.209 was uploaded manually from PC2 to fill the gap during PC1's downtime. No other problems found. 09/06/2006 07:51 darren@r 14:InputSyncDetect,14:InputSyncLost: Alarm has been well documented. We wil address this issue when it can be defined as a problem. 09/05/2006 08:40 Alan_Bro Weekly report from Ken Thomas: PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Sep 5, 2006 12:00:00 Page 1 09/04/06 GRA Coil 12 10 tags 11 hits 09/04/06 GRA Coil 14 10 tags 10 hits 09/04/06 GRA Coil 16 10 tags 10 hits 09/04/06 GRA Coil 18 10 tags 11 hits 09/04/06 GRA Coil 22 10 tags 11 hits 09/04/06 GRA Coil 24 10 tags 10 hits 09/04/06 GRA Coil 26 10 tags 10 hits 09/04/06 GRA Coil 28 10 tags 11 hits First Stick: 04-sep-2006 07:15:11 First File: GRA06247.103 Last Stick: 04-sep-2006 07:20:48 Last File: GRA06247.103 GRA 09/04/06 Total: 84 09/04/2006 10:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/09/04 07:17:50 09/04/2006 10:05 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/09/04 07:16:47 09/04/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/04 07:15:54 09/04/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/04 07:14:57 09/03/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/03 09:14:24 09/03/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/03 09:14:22 09/03/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/03 09:12:48 09/03/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/03 09:12:47 09/03/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/03 08:58:22 09/03/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/03 08:58:20 09/03/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/03 08:58:14 09/03/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/03 08:58:12 09/02/2006 08:09 alan@ruf 05:LowExcCurrent: No apparent reason for this alarm. This transceiver is reading PIT Tags. PTAGIS Field Operations will investigate during a site visit next week. 09/01/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/09/01 10:57:53 09/01/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/09/01 10:57:51 09/01/2006 13:05 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/09/01 10:37:10 09/01/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/09/01 10:14:19 09/01/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/09/01 10:14:15 09/01/2006 09:19 Don_Warf Site personnel report that the trap will be put back into operation at 10:30 PDT today. 08/31/2006 19:06 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/08/31 16:35:54 08/31/2006 19:06 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/08/31 16:35:53 08/31/2006 16:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/31 13:43:19 08/31/2006 16:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/31 13:43:18 08/31/2006 16:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/31 12:40:48 08/31/2006 16:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/31 12:40:47 08/31/2006 16:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/31 12:18:10 08/31/2006 16:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/31 12:18:10 08/31/2006 16:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/31 12:15:47 08/31/2006 16:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/31 12:15:47 08/31/2006 16:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/31 12:08:10 08/31/2006 16:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/31 12:08:10 08/31/2006 13:06 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/31 11:31:11 08/31/2006 13:06 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/31 11:31:10 08/30/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/30 10:58:15 08/30/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/30 10:58:15 08/30/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/30 10:55:40 08/30/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/30 10:55:39 08/30/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/30 10:33:35 08/30/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/30 10:33:34 08/30/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/08/30 10:32:25 08/30/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/08/30 10:32:24 08/30/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/08/30 10:32:16 08/30/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/30 10:32:16 08/30/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/08/30 10:32:15 08/30/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/30 10:32:15 08/30/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/30 10:13:19 08/30/2006 13:04 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/30 10:13:18 08/30/2006 10:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/08/30 08:59:07 08/30/2006 10:05 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/08/30 08:59:04 08/30/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/08/30 08:58:57 08/30/2006 10:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/08/30 08:58:51 08/30/2006 10:05 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/08/30 08:58:46 08/30/2006 10:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/30 08:58:42 08/30/2006 10:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/30 08:58:40 08/29/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/29 09:51:55 08/29/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/08/29 09:51:55 08/29/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/08/29 09:51:53 08/29/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/29 09:51:53 08/29/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/29 09:51:17 08/29/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/08/29 09:51:17 08/29/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/08/29 09:51:14 08/29/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/29 09:51:13 08/29/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/08/29 09:25:48 08/29/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/08/29 09:16:18 08/29/2006 13:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/08/29 09:16:14 08/29/2006 13:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/08/29 09:16:13 08/29/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/08/29 09:14:40 08/29/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/08/29 09:14:38 08/29/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/08/29 09:14:33 08/29/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/08/29 09:14:27 08/29/2006 13:05 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/08/29 09:14:24 08/29/2006 13:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/08/29 09:14:24 08/29/2006 13:05 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2006/08/29 09:14:23 08/29/2006 13:05 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2006/08/29 09:14:22 08/28/2006 07:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/08/28 05:08:08 08/28/2006 07:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/08/28 05:08:07 08/28/2006 04:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/08/28 02:53:44 08/28/2006 04:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/08/28 02:53:44 08/25/2006 08:43 dlwarf@r 01:ReaderReset: Common reader reset. 08/22/2006 16:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/08/22 12:23:16 08/22/2006 16:03 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/08/22 12:23:04 08/21/2006 07:40 darren@r 08:ReaderReset,14:InputSyncDetect,14:InputSyncLost: Alarms will be investigated during the next site visit. 08/18/2006 11:33 dlwarf@r 12:InputSyncLost,12:LowExcCurrent,14:InputSyncDetect,14:InputSyncLost: Ongoing problem. To be corrected before waterup. 08/17/2006 10:02 DGE_Robo SampleGate_B (SampleGate_B) changed from '7.5%' to '13.0%' at 2006/08/17 08:13:04 08/17/2006 10:02 DGE_Robo SampleGate_A (SampleGate_A) changed from '7.5%' to '13.0%' at 2006/08/17 08:13:04 08/16/2006 13:38 Darren A site GMC was performed today (8-16-06). All the transceivers were checked fro tuning, noise, and detection ability. The PC clocks were adjusted to be within 1 second of atomic time and each other. The "sync" cable between antennas 14 and 12 was removed. These antennas do not reside in the same monitor, this was done to try and troubleshoot the "sync" lost problems that we have been seeing between these two transcievers.If the problem appears again on 14 the problem is probably due to transceiver 16 which then can be replaced. 08/16/2006 07:08 scottl@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Pproblem will be addressed today. 08/14/2006 07:29 scottl@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Problems will be investigated on the next site visit. 08/11/2006 08:19 dlwarf@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Problem is being investigated. 08/09/2006 07:44 alan@ree 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: PTAGIS Field Operations will remedy this issue when time allows. The trap is currently not in service. 08/08/2006 08:05 alan@ree 12:InputSyncDetect,12:InputSyncLost: These issues are being investigated. 08/07/2006 07:37 alan@ree 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: These issues are being investigated. 08/03/2006 07:22 troy@ree 01:ReaderReset: Possible Random Reader Reset. 07/31/2006 13:23 Darren A site GMC was performed today (7-31-06). All transceivers were checked for tuning, noise, and detecability. The "sync" issues with transceivers 12 and 14 were going to be addressed but I was unable to determine which transciever needed to be replaced. This situation does not and will not effect the deteciton efficiencies for either detection system. PSMFC will have to wait for a hard failure of the "sync" input or output to solve this issue. The adult trap is still out of operation. 07/31/2006 07:31 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This alarm will be addressed today during site GMC's. 07/27/2006 07:28 troy@ree 12:BadOscFreq,12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:In putSyncLost: Noted 07/26/2006 07:08 scottl@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Errors not of concern at this time 07/25/2006 09:06 troy@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This is a known issue, clearing TASS 07/24/2006 11:07 Don_Warf Ken Thomas reports that due to high water temps, sampling was stopped on Friday July 21st at 11:00am PDT. He also reports that the trap was shut down today at 9:40am PDT. Operations will resume when water temps drop. 07/24/2006 10:02 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/07/24 08:40:39 07/22/2006 13:02 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/07/22 10:09:16 07/22/2006 13:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/07/22 10:09:15 07/21/2006 15:45 Dave I updated the database and map files to GRA06202.DB and GRA06202.MAP, respectively. This configuration provides codes and instructions to divert any of ~480k fall Chinook to the NMFS trap. I reset the PC clocks to within 1 second of each other and atomic time. 07/20/2006 07:39 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: PSMFC will address these detection systems when time allows. These alarms are not impacting detection efficiencies. 07/20/2006 07:25 Alan_Bro Weekly report from Ken Thomas PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Jul 19, 2006 12:00:00 Page 1 07/17/06 GRA Coil 12 10 tags 10 hits 07/17/06 GRA Coil 14 10 tags 10 hits 07/17/06 GRA Coil 16 10 tags 10 hits 07/17/06 GRA Coil 18 10 tags 10 hits 07/17/06 GRA Coil 22 10 tags 10 hits 07/17/06 GRA Coil 24 10 tags 10 hits 07/17/06 GRA Coil 26 10 tags 10 hits 07/17/06 GRA Coil 28 10 tags 10 hits First Stick: 17-jul-2006 06:52:34 First File: GRA06198.103 Last Stick: 17-jul-2006 06:54:43 Last File: GRA06198.103 GRA 07/17/06 Total: 80 07/19/2006 09:01 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: These alarms will be addressed when time allows. The detection efficiencies have not been impacted by this alarm. 07/18/2006 17:10 Scott_Li Ken Thomas verified data collection computers are functional and collecting data. 07/18/2006 16:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/07/18 12:34:20 07/18/2006 16:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/07/18 12:34:18 07/18/2006 13:07 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/07/18 11:19:21 07/18/2006 13:07 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/07/18 11:19:20 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/18 10:30:12 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/18 10:29:14 07/18/2006 13:07 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/18 10:22:16 07/18/2006 13:07 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/18 10:21:05 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/18 10:13:31 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/18 10:13:27 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/18 10:13:20 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/18 10:13:18 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/18 10:13:11 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/18 10:13:09 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/18 09:35:40 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/18 09:35:36 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/18 09:35:33 07/18/2006 13:07 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/18 09:35:29 07/18/2006 13:07 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/18 09:25:22 07/18/2006 13:07 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/18 09:25:19 07/18/2006 13:06 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/18 09:20:21 07/18/2006 13:06 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/18 09:20:17 07/18/2006 13:06 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/18 09:20:09 07/18/2006 13:06 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/18 09:20:07 07/18/2006 11:11 Dave Re-activated auto-upload on PC1 and transferred all outstanding files. Archived all outstanding files on PC2. PC clocks are within 5 seconds of each other and 100 seconds of atomic time. 07/18/2006 10:37 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/17 06:55:14 07/18/2006 10:37 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/17 06:54:06 07/18/2006 10:37 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/17 06:53:20 07/18/2006 10:37 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/17 06:52:20 07/14/2006 13:22 Scott_Li The auto upload process was disengaged until further notice due to the scheduled outage of the central database. The sites will not upload files until possibly Monday the 17th or 18th or when the central database resumes normal operations.. 07/14/2006 13:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/07/14 09:03:09 07/14/2006 13:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/07/14 09:03:08 07/14/2006 09:08 alan@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Transceiver 16 appears as the likely culprit and will be replaced on the next site visit. 07/13/2006 07:50 alan@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This alarm will be addressed by PSMFC personnel on the next site visit. We will repair or replace the necessary componenets. 07/12/2006 11:24 Dave I replaced GRJ-GEN.DB with the current version from the PTAGIS file server, and reloaded the database into MultiMon. The PC clocks are within 2 seconds of each other and 16 seconds of atomic time. 07/12/2006 09:26 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This alarm will be addressed by PSMFC personnel on the next site visit. We will repair or replace the necessary componenets. 07/11/2006 07:35 troy@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: A possible cause to these alarms was witnessed during a GMC on 7/10/06. 16 went into high noise, putting 12,14 and 18 into standby did not eliminate the noise on 16. A minor tweek on the tuning capacitor eliminated the noise. PSMFC will replace 16 on the next site visit to see if this eliminated the Sync problems. 07/11/2006 07:26 troy@ruf 12:TestTagFailure,14:TestTagFailure,18:TestTagFailure: These alarms were generated during a GMC 07/10/2006 11:43 Troy A site GMC was performed today (07/10/07). All transcievers were checked for tune. The slot and orfice antenna's are experiencing periodic noise that can not be tuned out. The water level is about 2 feet lower than the water line. Site personel report that they have seen ladder level flucuation. This may contribute to the noise problem but the ultra sonic level transmitter is the most likely culprite. The COE is reportedly in the process of replacing this level transmitter. While checking the adult trap 16 went into a high noise condition. Putting the other transcievers into standby (18, 14 and 12) did not rectifiy the problem. The noise went away while tuning the transciever. PSMFC has been monitoring sinc issue with 14 and 16. PSMFC will continue to monitor this situation and possibly replace 16 on the next site visit. 07/10/2006 10:11 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/10 08:06:55 07/10/2006 10:11 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/10 08:05:42 07/10/2006 10:11 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/10 08:04:56 07/10/2006 10:11 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/10 08:03:47 07/10/2006 10:11 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/07/10 07:28:14 07/10/2006 10:11 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/07/10 07:28:12 07/10/2006 10:11 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/07/10 06:00:01 07/10/2006 10:11 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/07/10 06:00:01 07/10/2006 09:35 Scott_Li Per Ken Thomas, the trap was closed due to hi water temperatures on July 9,06 @ 0800 hrs and re-opened today July 10, 2006 at 0830. Today's water temperature is at 69 F. 07/10/2006 09:24 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/07/06 06:00:01 07/10/2006 09:24 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/07/06 06:00:01 07/09/2006 11:23 troy@ruf 14:InputSyncDetect,14:InputSyncLost: Noted. 07/09/2006 10:04 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/07/09 06:54:07 07/09/2006 10:04 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/07/09 06:54:06 07/07/2006 16:55 Scott_Li The problem with the COE DNS server has been corrected. PCA'd into sites and returned the URL in the uploader back to the default. Sent diagnostic test PTAGIS server to check for typo's, tested good. 07/06/2006 12:42 Dave Replaced "ftp.ptagis.org" URL in PTTP-Uploader with the explicit numeric IP address and successfully uploaded outstanding files on PC1. 07/06/2006 10:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/07/06 05:11:35 07/06/2006 10:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/07/06 05:11:34 07/06/2006 10:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/07/06 05:03:26 07/06/2006 10:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/07/06 05:03:26 07/06/2006 10:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/07/06 01:56:51 07/06/2006 10:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/07/06 01:56:50 07/06/2006 09:53 Dave Reset PTTP-Uploader URL to ftp.ptagis.org on PC1. This destination URL is required in order for PTAGIS to acquire and queue uploaded data files. Manually re-transferred previously-sent files. 07/06/2006 09:22 Dave Set PTTP-Uploader URL to ftp.psmfc.org on PC1. Successfully uploaded all outstanding data files. Reset both PC clocks to within 1 second of each other and atomic time. Archived all outstanding data files on PC2. 07/06/2006 07:54 Scott_Li PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Jul 5, 2006 12:00:00 07/03/06 GRA Coil 12 10 tags 10 hits 07/03/06 GRA Coil 14 10 tags 10 hits 07/03/06 GRA Coil 16 10 tags 10 hits 07/03/06 GRA Coil 18 10 tags 10 hits 07/03/06 GRA Coil 22 10 tags 10 hits 07/03/06 GRA Coil 24 10 tags 10 hits 07/03/06 GRA Coil 26 10 tags 10 hits 07/03/06 GRA Coil 28 10 tags 10 hits First Stick: 03-jul-2006 06:55:32 First File: GRA06184.103 Last Stick: 03-jul-2006 06:58:00 Last File: GRA06184.103 GRA 07/03/06 Total: 80 Ken Thomas weekly stick test report indicates no problems found. 07/05/2006 07:15 scottl@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: On-going issue, not of concern at this time, Alarms are not effecting detection efficiencies. 07/03/2006 10:16 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/07/03 06:58:22 07/03/2006 10:16 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/07/03 06:57:22 07/03/2006 10:16 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/07/03 06:56:16 07/03/2006 10:16 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/07/03 06:55:19 07/03/2006 07:57 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: These alarms will be addressed on the next site visit. The sync lost will not impact detection efficiency. 07/02/2006 08:49 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: These alarms will be addressed on the next site visit. 06/29/2006 07:20 darren@r 01:ReaderReset,02:ReaderReset,03:ReaderReset,04:ReaderReset,05:ReaderReset ,06:ReaderReset,07:ReaderReset,08:ReaderReset,12:InputSyncDetect,12:InputS yncLost,12:ReaderReset,14:InputSyncDetect,14:InputSyncLost,14:ReaderReset, 16:InputSyncDetect,16:ReaderReset,18:ReaderReset,22:InputSyncDetect,22:Rea derReset,24:InputSyncDetect,24:ReaderReset,26:InputSyncDetect,26:ReaderRes et,28:ReaderReset: It appears that there were 2 power outages separated by a few minutes. PSMFC will verify this with site personnel. 06/29/2006 07:19 Scott_Li PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Jun 28, 2006 12:00:00 06/26/06 GRA Coil 12 10 tags 10 hits 06/26/06 GRA Coil 14 10 tags 10 hits 06/26/06 GRA Coil 16 10 tags 10 hits 06/26/06 GRA Coil 18 10 tags 10 hits 06/26/06 GRA Coil 22 10 tags 10 hits 06/26/06 GRA Coil 24 10 tags 10 hits 06/26/06 GRA Coil 26 10 tags 10 hits 06/26/06 GRA Coil 28 10 tags 10 hits Ken Thomas weekly stick test report, No problems detected 06/28/2006 13:18 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/28 11:58:44 06/28/2006 13:18 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/06/28 11:58:43 06/28/2006 13:18 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/06/28 11:58:15 06/28/2006 13:18 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/28 11:58:15 06/28/2006 13:18 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/28 11:37:08 06/28/2006 13:18 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/06/28 11:37:08 06/28/2006 13:18 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/06/28 11:36:25 06/28/2006 13:18 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/28 11:36:24 06/28/2006 13:18 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/28 11:36:07 06/28/2006 13:18 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/28 11:36:06 06/28/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/28 07:45:36 06/28/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/28 07:45:35 06/28/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/28 06:56:23 06/28/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/28 06:56:23 06/28/2006 07:21 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: PSMFC is aware of these transceivers and we will address the alarms when time allows. These alarms should not affect the detection ability of the system. 06/27/2006 07:48 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This alarm will be addressed on the next site visit. PSMFC is trying to coordinate the site visit with the failure so we can better determine which of the two transceivers in question need to be replaced. 06/26/2006 11:51 Troy A GMC was performed today (6/26/06). All transcievers were checked for tune and adjustments made where needed. PC2 is 3 second's behind PC1 and PC1 is 40 seconds behind atomic time. The lower AC unit in the pittag room is in need of repair or replacement. The circuit breaker was found to be tripped and would not reset. I unplugged the unit and was able to reset the circuit breaker. However when the unit was plugged back in the breaker tripped again. The upper unit was turned to hi cool and the temperature setpoint lowered. The heat is not overbearing in the pittag room and should not result in an adverse condition for the electronic equipment at this time. 06/26/2006 10:04 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/06/26 06:59:54 06/26/2006 10:04 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/06/26 06:58:38 06/26/2006 10:04 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/06/26 06:57:09 06/26/2006 10:04 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/06/26 06:56:05 06/21/2006 08:58 troy@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This is an ongoing problem. See previous posting on this problem. 06/20/2006 07:34 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This situation is being monitored by PSMFC. We are trying to determine which transceiver is failing. We have to let the sync out fail to determine which transceiver to replace. This alarm does not impact PTItag detection efficiencies. 06/19/2006 13:08 Alan A GMC was performed 6/19/2006. All transceivers were checked and tuned as necessary. The west flume is showing no signs of trouble. The exciter cables were re-dressed on the west flume in an effort to determine the cause of the sync issues with that monitor. The clocks on both PCs were set to within one second of atomic time. No activity was observed on PC2 during PC1's downtime. Multimon is running in full screen DOS mode on both PCs. No other problems found. 06/19/2006 10:22 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/06/19 07:23:39 06/19/2006 10:22 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/06/19 07:22:43 06/19/2006 10:22 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/06/19 07:20:52 06/19/2006 10:22 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/06/19 07:19:55 06/19/2006 08:24 scottl@r 14:InputSyncDetect,14:InputSyncLost: Errors are not of concern at this time, GMC will be performed today. 06/17/2006 10:28 troy@ree 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Random Reader Reset. This is a known problem. 06/14/2006 07:45 troy@ree 14:InputSyncDetect,14:InputSyncLost: Noted 06/12/2006 10:20 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/06/12 06:55:25 06/12/2006 10:20 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/06/12 06:54:20 06/12/2006 10:20 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/06/12 06:53:27 06/12/2006 10:20 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/06/12 06:52:23 06/11/2006 09:12 alan@ree 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Alarms will be investigated during the next site visit. 06/09/2006 13:23 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/06/09 10:19:21 06/09/2006 13:23 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/06/09 10:19:19 06/08/2006 11:15 Darren A site GMC was performed today (6-8-06). All transceivers were checked for tuning, noise and detection ability. The PC clocks are within 40 seconds of atomic time and 4 seconds of each other. No problems were found. 06/07/2006 08:13 alan@ree 06:ReaderReset,12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:I nputSyncLost: Alrms will be investigated during a site visit 6/8/2006. 06/07/2006 07:57 Alan_Bro Transceiver 07 appears to be in tune but experiencing some noise. PCA'd into PC2 and manually fired the timer tag. PTAGIS Field Operations will continue to monitor the situation. 06/06/2006 08:25 troy@ree 14:InputSyncDetect,14:InputSyncLost: This alarm has been noted in the past and 16 is suspected to be the problem. 06/06/2006 07:41 Scott_Li PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Jun 5, 2006 12:00:00 06/05/06 GRA Coil 12 10 tags 10 hits 06/05/06 GRA Coil 14 10 tags 10 hits 06/05/06 GRA Coil 16 10 tags 10 hits 06/05/06 GRA Coil 18 10 tags 10 hits 06/05/06 GRA Coil 22 10 tags 10 hits 06/05/06 GRA Coil 24 10 tags 10 hits 06/05/06 GRA Coil 26 10 tags 10 hits 06/05/06 GRA Coil 28 10 tags 10 hits First Stick: 05-jun-2006 07:32:06 First File: GRA06156.103 Last Stick: 05-jun-2006 07:34:22 Last File: GRA06156.103 GRA 06/05/06 Total: 80 Weekly stick test results, no problems detected. 06/05/2006 16:06 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/05 14:36:14 06/05/2006 16:06 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/05 14:36:14 06/05/2006 10:17 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/06/05 07:34:34 06/05/2006 10:17 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/06/05 07:33:46 06/05/2006 10:17 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/06/05 07:32:51 06/05/2006 10:17 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/06/05 07:31:55 06/05/2006 07:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/06/05 03:34:42 06/05/2006 07:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/06/05 03:34:42 06/04/2006 08:48 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: These alarms will be addressed on the next site visit. I believe that the problem is actually on transceiver 16. 06/02/2006 09:00 dlwarf@r 03:ReaderReset,12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:I nputSyncLost: To be investigated during the next GMC. 06/01/2006 07:48 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This system was checked by PSMFC personnel. We will monitor and repair or replce the suspect systems as necessary. 05/31/2006 11:29 Scott_Li PIT Tag Database Stick Tag Summary Report By Site, Date and Coil May 31, 2006 12:00:00 05/29/06 GRA Coil 12 10 tags 10 hit 05/29/06 GRA Coil 14 10 tags 10 hits 05/29/06 GRA Coil 16 10 tags 10 hits 05/29/06 GRA Coil 18 10 tags 10 hits 05/29/06 GRA Coil 22 10 tags 10 hits 05/29/06 GRA Coil 24 10 tags 10 hits 05/29/06 GRA Coil 26 10 tags 10 hits 05/29/06 GRA Coil 28 10 tags 10 hits First Stick: 29-may-2006 08:07:14 First File: GRA06149.103 Last Stick: 29-may-2006 08:09:41 Last File: GRA06149.103 GRA 05/29/06 Total: 80 Ken Thomas weekly stick test results, no problems detected. 05/31/2006 07:40 darren@r 14:InputSyncDetect,14:InputSyncLost: The alarms may have been generated by PSMFC personnel. PSMFC will continue to monitor for future alarms. 05/30/2006 11:40 Alan A GMC was performed 5/30/2006. All transceivers were checked and tuned as necessary. The Milltronics level sensor just down stream from Antennas 07 and 08 is still creating noise. Site personnel report that the radar alternative is on order and should be deployed by the end of June. The backlight in the adult trap's Panel View 600 was replaced and the screen saver was enabled. The clocks on both PCs were set to within one second of atomic time. No activity was observed on PC2 during PC1's downtime. No other problems found. 05/29/2006 10:21 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/05/29 08:10:00 05/29/2006 10:21 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/05/29 08:09:05 05/29/2006 10:21 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/05/29 08:08:04 05/29/2006 10:21 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/05/29 08:07:03 05/26/2006 08:45 darren@r 07:ReaderReset: Alarm will be addressed on the next site visit. 05/25/2006 07:41 scottl@r 03:ReaderReset: Noted 05/22/2006 10:30 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/05/22 07:19:45 05/22/2006 10:30 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/05/22 07:18:45 05/21/2006 09:49 troy@ruf 08:TestTagFailure: Noted 05/20/2006 09:36 troy@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Possible Reader Reset. PSMFC will monitor for future occurances 05/19/2006 07:28 troy@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: This will be looked into on the next site visit. 05/18/2006 07:20 scottl@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Not an issue at this time, will monitor 05/17/2006 16:52 DGE_Robo SampleGate_B (SampleGate_B) changed from '10.0%' to '7.5%' at 2006/05/17 13:47:55 05/17/2006 16:52 DGE_Robo SampleGate_A (SampleGate_A) changed from '10.0%' to '7.5%' at 2006/05/17 13:47:42 05/17/2006 07:43 troy@ruf 01:ReaderReset,02:ReaderReset,03:ReaderReset,04:ReaderReset,05:ReaderReset ,06:ReaderReset,07:ReaderReset,08:ReaderReset,12:InputSyncDetect,12:InputS yncLost,12:ReaderReset,14:InputSyncDetect,14:InputSyncLost,14:ReaderReset, 16:InputSyncDetect,16:ReaderReset,18:ReaderReset,22:InputSyncDetect,22:Inp utSyncLost,22:ReaderReset,24:InputSyncDetect,24:InputSyncLost,24:ReaderRes et,26:InputSyncDetect,26:ReaderReset,28:ReaderReset: These alarms were the result of a brief power outage. 05/16/2006 14:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/05/16 09:13:58 05/16/2006 14:00 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/05/16 09:13:57 05/16/2006 14:00 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/05/16 09:13:52 05/16/2006 14:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/05/16 09:13:51 05/16/2006 13:12 Darren A site GMC was performed today (5-16-06). All transceivers were checked for tuning, noise, and detection ability. No problems were found. the PC clocks are within 30 seconds of atomic time and 3 seconds of each other. 05/16/2006 12:39 Scott_Li PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) May 16, 2006 12:00:00 05/15/06 GRA Coil 12 10 tags 10 hits 05/15/06 GRA Coil 14 10 tags 10 hits 05/15/06 GRA Coil 16 10 tags 10 hits 05/15/06 GRA Coil 18 10 tags 10 hits 05/15/06 GRA Coil 22 10 tags 10 hits 05/15/06 GRA Coil 24 10 tags 10 hits 05/15/06 GRA Coil 26 10 tags 10 hits 05/15/06 GRA Coil 28 10 tags 10 hits First Stick: 15-may-2006 07:38:07 First File: GRA06135.103 Last Stick: 15-may-2006 07:40:46 Last File: GRA06135.103 GRA 05/15/06 Total: 80 Ken Thomas weekly stick test report indicates no problems found 05/16/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/05/16 08:16:56 05/16/2006 10:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/05/16 08:16:55 05/16/2006 07:19 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: Alarms will be investigated today during a site GMC. 05/15/2006 10:23 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/05/15 07:41:00 05/15/2006 10:23 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/05/15 07:40:05 05/15/2006 10:23 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/05/15 07:39:10 05/15/2006 10:23 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/05/15 07:37:47 05/15/2006 07:16 darren@r 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: No explanation for these alarms. PSMFC will monitor for future alarms. Generally we would receive a reader reset but none was viewed in the raw file. 05/14/2006 10:24 alan@ruf 12:InputSyncDetect,12:InputSyncLost,14:InputSyncDetect,14:InputSyncLost: These transceivers are reading timer tags and PIT Tags with high efficiency. PTAGIS Field Operations will investigate on the next site visit. 05/12/2006 09:25 Alan_Bro A GMC was performed 5/9/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs were set to within one second of atomic time. No activity was observed on PC2 during PC1's downtime. The remedy for the level sensor noise is ongoing. No other problems found. 05/08/2006 11:42 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/05/08 06:41:41 05/08/2006 11:42 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/05/08 06:40:34 05/08/2006 11:42 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/05/08 06:39:51 05/08/2006 11:42 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/05/08 06:38:33 05/05/2006 14:21 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/05/05 09:04:47 05/05/2006 14:21 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/05/05 09:03:41 05/05/2006 14:21 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/05/05 09:02:43 05/05/2006 14:21 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/05/05 09:01:08 05/05/2006 11:27 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/05/05 08:22:43 05/05/2006 11:27 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/05/05 08:16:29 05/05/2006 11:27 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/05/05 08:16:26 05/05/2006 08:39 Don_Warf Site personnel report that the trap was put back into operation today at 8:30. The sample rate is 10%. 05/03/2006 17:54 DGE_Robo SampleGate_B (SampleGate_B) changed from '13.0%' to '10.0%' at 2006/05/03 12:48:11 05/03/2006 17:54 DGE_Robo SampleGate_A (SampleGate_A) changed from '13.0%' to '10.0%' at 2006/05/03 12:48:11 05/03/2006 13:59 Alan A GMC was performed 5/3/2006. All transceivers were checked and tuned as necessary. The ground lead on the ultrasonic level sensor was changed to no avail. A new radar sensor is being procured by the USACE. Both PCs are within 20 seconds of atomic time. Multimon is running in full screen DOS mode on both PCs. No other problems found. 04/27/2006 11:39 Scott_Li Antennas 05 and 06 have been consistently detecting 1 unique fish over the course of about 2 weeks. |09 06 06/04/24 09:18:03 3D9.1BF23B8DE2 NOTFound| 12853, |08 05 06/04/26 23:02:57 3D9.1BF23B8DE2 NOTFound| 2241. It appears that this Juvenile fishy just likes this weir and is in no hurry to transit further down the ladder. 1 fish history indicates "First OBS on 4/13/06 and Last OBS on 4/27/06, Migration year 2006, length 123 mm, release site Dworshak. This exercise was to ensure that this detection was not a loose or shed PIT-tag rolling around in weir 731. 04/27/2006 09:55 scottl@r 01:ReaderReset: Noted 04/25/2006 14:14 Alan A GMC was performed 4/25/2006. All transceivers were checked and tuned as necessary. Transceivers 07 and 08 are showing noise rolling from 4% to 40%. The Milltronics level sensor just down stream from Antennas 07 and 08 was confirmed as the noise source when site personnel powered it down. It is suspected that the shield grounding needs to be replaced. Site personnel are scheduling repairs. Transceiver 02 is showing noise in the teens. During the course of troubleshooting the level sensor noise, several self-ballasting flourescent bulbs were spotted in galleries on several levels of the dam. Also noticed were new flourescent four-tube fixtures with electronic ballasts. Turning off the self-ballasting flourescent bulbs we knew about got the signal level down to ten percent. Not all of the the electronic ballasts could be turned off for the test. Efficiencies are high for this transceiver but a problem could be looming as more of the incandescent bulbs are cycled out. The clocks on both PCs were set to within one second of atomic time. No activity was observed on PC2 during PC1's downtime. No other problems found. 04/22/2006 11:11 Don_Warf All WW District sites now back on-line. Source of outage unknown. -----Original Message----- From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Saturday, April 22, 2006 10:34 AM To: pitevent-list@psmfc.org Subject: pitevent for site(s) ICH GOJ MCJ GRA GRJ MC2 LMJ MC1 For site(s) ICH GOJ MCJ GRA GRJ MC2 LMJ MC1, Don_Warf (Posted via mail from "Don Warf" ) sends the following PITTAG event: I am currently investigating why all COE Walla Walla District sites did not load. ----Original Message----- From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Saturday, April 22, 2006 10:15 AM To: sitemaint@psmfc.org Subject: Problems with remote data sites... The following problems with remote sites were detected; ich: Last data submission was received on Sat Apr 22 6:00:57 PST 2006 goj: Last data submission was received on Sat Apr 22 6:02:30 PST 2006 mcj: Last data submission was received on Sat Apr 22 6:02:26 PST 2006 gra: Last data submission was received on Sat Apr 22 6:03:03 PST 2006 grj: Last data submission was received on Sat Apr 22 6:02:21 PST 2006 mc2: Last data submission was received on Sat Apr 22 6:03:18 PST 2006 lmj: Last data submission was received on Sat Apr 22 6:02:35 PST 2006 mc1: Last data submission was received on Sat Apr 22 6:02:40 PST 2006 Please check this out. 04/22/2006 10:34 Don_Warf I am currently investigating why all COE Walla Walla District sites did not load. ----Original Message----- From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Saturday, April 22, 2006 10:15 AM To: sitemaint@psmfc.org Subject: Problems with remote data sites... The following problems with remote sites were detected; ich: Last data submission was received on Sat Apr 22 6:00:57 PST 2006 goj: Last data submission was received on Sat Apr 22 6:02:30 PST 2006 mcj: Last data submission was received on Sat Apr 22 6:02:26 PST 2006 gra: Last data submission was received on Sat Apr 22 6:03:03 PST 2006 grj: Last data submission was received on Sat Apr 22 6:02:21 PST 2006 mc2: Last data submission was received on Sat Apr 22 6:03:18 PST 2006 lmj: Last data submission was received on Sat Apr 22 6:02:35 PST 2006 mc1: Last data submission was received on Sat Apr 22 6:02:40 PST 2006 Please check this out. 04/21/2006 13:42 Don_Warf Site personnel report that due to lack of fish, sampling was stopped at 13:00 yesterday. The trap was de-watered today at 12:30. Sampling will restart when numbers increase. Possibly within the next three weeks. 04/20/2006 16:23 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/04/20 12:06:26 04/20/2006 16:23 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/04/20 12:06:24 04/20/2006 13:22 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/04/20 11:49:53 04/20/2006 12:05 Alan_Bro A GMC was performed 4/20/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs are within 20 seconds of atomic time, no problems found. 04/17/2006 13:42 Alan_Bro Weekly stick test from Ken Thomas PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Apr 17, 2006 12:00:00 Page 1 04/17/06 GRA Coil 12 10 tags 10 hits 04/17/06 GRA Coil 14 10 tags 10 hits 04/17/06 GRA Coil 16 10 tags 10 hits 04/17/06 GRA Coil 18 10 tags 10 hits 04/17/06 GRA Coil 22 10 tags 10 hits 04/17/06 GRA Coil 24 10 tags 10 hits 04/17/06 GRA Coil 26 10 tags 10 hits 04/17/06 GRA Coil 28 10 tags 10 hits First Stick: 17-apr-2006 06:28:02 First File: GRA06107.103 Last Stick: 17-apr-2006 06:30:42 Last File: GRA06107.103 GRA 04/17/06 Total: 80 04/17/2006 10:10 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/04/17 06:31:12 04/17/2006 10:10 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/04/17 06:29:56 04/17/2006 10:10 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/04/17 06:27:46 04/17/2006 10:10 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/04/17 06:27:44 04/13/2006 10:07 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/04/13 06:06:35 04/13/2006 10:07 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/04/13 06:06:34 04/13/2006 07:08 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/04/13 05:37:30 04/13/2006 07:08 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/04/13 05:37:29 04/12/2006 13:43 Alan A GMC was performed 4/12/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs were adjusted to within one second of atomic time. GRA06102.208 was uploaded manually from PC2 to fill the gap during PC1s downtime. No problems found. 04/10/2006 16:23 Alan_Bro Weekly stick test from Ken Thomas. PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Apr 10, 2006 12:00:00 Page 1 04/10/06 GRA Coil 12 10 tags 10 hits 04/10/06 GRA Coil 14 10 tags 10 hits 04/10/06 GRA Coil 16 10 tags 10 hits 04/10/06 GRA Coil 18 10 tags 10 hits 04/10/06 GRA Coil 22 10 tags 10 hits 04/10/06 GRA Coil 24 10 tags 10 hits 04/10/06 GRA Coil 26 10 tags 10 hits 04/10/06 GRA Coil 28 10 tags 10 hits First Stick: 10-apr-2006 06:44:19 First File: GRA06100.103 Last Stick: 10-apr-2006 06:46:48 Last File: GRA06100.103 GRA 04/10/06 Total: 80 04/10/2006 10:13 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/04/10 06:47:13 04/10/2006 10:13 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/04/10 06:46:05 04/10/2006 10:13 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/04/10 06:45:16 04/10/2006 10:13 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/04/10 06:44:03 04/09/2006 09:09 alan@ruf 08:ReaderReset: This alarm was generated by a random reader reset. PSMFC and Digital Angel are aware of the problem. 04/07/2006 14:50 Darren We were on site today 4-7-06 to perform site GMC's. No problems were found at GRA. At GRJ we had two issues that were being dealt with. The first was the leaking water from the end of the Adult fallback Monitor which was creating a possible slip hazard. Alan and I tried to figure out the best way to seal the leak. We have inserted screws with waterstop washers in the holes but we discovered that the water is also leaking from the seams of the sheetmetal flanges. PSMFC will discuss the best way to address this situation next week, the flume cannot be rendered dry according to site Bio Kent blevins. The second issue was to place the plug into the solenoid to try and balance the air better so that we can remove the snubbers, this is currently working at GOJ but I was unable to make it work here for now. the solenoids were replaced back to normal as well the PLC settings and twenty sticks were passed through both "A" and "B" monitors to check timing. No problems were found. 04/07/2006 12:41 Alan_Bro A GMC was performed 4/7/2006. All transceivers were checked and tuned as necessary, no problems found. 04/04/2006 22:09 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/04/04 19:53:46 04/04/2006 22:09 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/04/04 19:53:46 04/03/2006 10:08 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/04/03 06:49:14 04/03/2006 10:08 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/04/03 06:47:48 04/03/2006 10:08 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/04/03 06:46:50 04/03/2006 10:08 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/04/03 06:45:33 04/03/2006 09:21 Dave pcA'd into the site's PC2 computer. Stopped and restarted MultiMon to reset "normal" data file generation times, which were disrupted yesterday by the shift from PST to PDT. Darren had already done this to the PC1 computer yesterday. Archived the accumulated data files on PC2. Verified that the two PC clocks were within our standard tolerances (less than five seconds discrepancy between PCs, and less than 30 seconds discrepancy between either PC and atomic time). 04/02/2006 11:01 darren Multimon was stopped and restarted as well as PTTP uploader. This was due to daylight savings. Darren R. Chase PSMFC Systems Engineer (509) 735-2773 ext.3 darren@psmfc.org 04/01/2006 08:55 darren@r 01:ReaderReset,02:ReaderReset,03:ReaderReset,04:ReaderReset,05:ReaderReset ,06:ReaderReset,07:ReaderReset,08:ReaderReset,12:InputSyncDetect,12:Reader Reset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:ReaderReset, 18:ReaderReset,22:InputSyncDetect,22:ReaderReset,24:InputSyncDetect,24:Rea derReset,26:InputSyncDetect,26:ReaderReset,28:ReaderReset: These alarms appear to have been caused by a brief power outage. 03/31/2006 12:16 Dave SMP personnel at Lower Granite inform us there was a power outage between 0840 and 0915 hours today. There may be further interruptions. 03/31/2006 12:07 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/03/31 09:14:47 03/31/2006 12:07 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/03/31 09:14:46 03/31/2006 12:07 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2006/03/31 08:53:23 03/31/2006 12:07 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/03/31 08:53:22 03/28/2006 08:17 darren@r 04:BadOscFreq: No direct cause for this alarm. PSMFC will monitor for future alarms and address them on the next site visit. 03/27/2006 14:08 scott PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Mar 27, 2006 12:00:00 03/27/06 GRA Coil 12 10 tags 10 hits 03/27/06 GRA Coil 14 10 tags 10 hits 03/27/06 GRA Coil 16 10 tags 10 hits 03/27/06 GRA Coil 18 10 tags 10 hits 03/27/06 GRA Coil 22 10 tags 10 hits 03/27/06 GRA Coil 24 10 tags 10 hits 03/27/06 GRA Coil 26 10 tags 10 hits 03/27/06 GRA Coil 28 10 tags 10 hits First Stick: 27-mar-2006 06:55:12 First File: GRA06086.103 Last Stick: 27-mar-2006 06:57:34 Last File: GRA06086.103 Ken Thomas weekly stick tag report indicates no problems with detection efficiency. 03/27/2006 12:07 Alan A GMC was performed 3/27/2006. All transceivers were checked and tuned as necessary. No problems found. 03/27/2006 09:02 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/03/27 06:58:03 03/27/2006 09:02 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/03/27 06:56:54 03/27/2006 09:02 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/27 06:56:05 03/27/2006 09:02 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/27 06:54:54 03/23/2006 15:06 Dave Reset default SbyC configuration on both GRA computers. Zipped archived data files. Deleted all but seasonal summary counter files. Deleted 2005 log files. Reset and deleted counter files (including the reference to 21 fish detected so far in 2006). The clocks on the PCs are within 5 seconds of each other and atomic time. The GRA platform is now initialized for the 2006 adult migration season. 03/21/2006 12:37 Alan A GMC was performed 3/21/2006. All transceivers were checked and tuned as necessary. The clocks on both PCs were set to within one second of atomic time. No activity was observed on PC2 during PC1's downtime. No other problems found. 03/20/2006 11:35 Alan_Bro Weekly stick test from Ken Thomas. PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Mar 20, 2006 12:00:00 Page 1 03/20/06 GRA Coil 12 10 tags 10 hits 03/20/06 GRA Coil 14 10 tags 10 hits 03/20/06 GRA Coil 16 10 tags 10 hits 03/20/06 GRA Coil 18 10 tags 10 hits 03/20/06 GRA Coil 22 10 tags 10 hits 03/20/06 GRA Coil 24 10 tags 10 hits 03/20/06 GRA Coil 26 10 tags 10 hits 03/20/06 GRA Coil 28 10 tags 10 hits First Stick: 20-mar-2006 08:09:55 First File: GRA06079.103 Last Stick: 20-mar-2006 08:12:11 Last File: GRA06079.103 GRA 03/20/06 Total: 80 03/20/2006 09:06 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/03/20 08:12:29 03/20/2006 09:06 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/20 08:10:44 03/20/2006 09:06 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/03/20 08:09:41 03/20/2006 09:06 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/20 08:09:39 03/15/2006 18:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/03/15 17:17:59 03/15/2006 18:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/03/15 17:17:58 03/15/2006 15:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/03/15 13:38:07 03/15/2006 15:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/03/15 13:38:07 03/15/2006 15:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/03/15 13:38:00 03/15/2006 15:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/03/15 13:37:59 03/14/2006 14:53 Troy With Alan's help the hardware files for GRA were changed and pushed up to the GRA MultiMon configuration folder on the PTAGIS FTP server. The changes that were made are as follows: 1: Set WEST SBYC EVENT ON 1: Reset WEST SBYC EVENT OFF 2: Set EAST SBYC EVENT ON 2: Reset EAST SBYC EVENT OFF changed to: 1: Set WEST SXC GATE OPEN 1: Reset WEST SXC GATE CLOSED 2: Set EAST SXC GATE OPEN 2: Reset EAST SXC GATE CLOSED GRA06073.208 was used to fill the gap while PC1 was being changed 03/14/2006 14:52 Troy With Alan's help the hardware files for GRA were changed and pushed up to the GRA MultiMon configuration folder on the PTAGIS FTP server. The changes that were made are as follows: 1: Set WEST SBYC EVENT ON 1: Reset WEST SBYC EVENT OFF 2: Set EAST SBYC EVENT ON 2: Reset EAST SBYC EVENT OFF changed to: 1: Set WEST SXC GATE OPEN 1: Reset WEST SXC GATE CLOSED 2: Set EAST SXC GATE OPEN 2: Reset EAST SXC GATE CLOSED 03/14/2006 08:46 Alan_Bro Weelky stick test from Ken Thomas. PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Mar 14, 2006 12:00:00 03/13/06 GRA Coil 12 10 tags 10 hits 03/13/06 GRA Coil 14 10 tags 10 hits 03/13/06 GRA Coil 16 10 tags 10 hits 03/13/06 GRA Coil 18 10 tags 10 hits 03/13/06 GRA Coil 22 10 tags 10 hits 03/13/06 GRA Coil 24 10 tags 10 hits 03/13/06 GRA Coil 26 10 tags 10 hits 03/13/06 GRA Coil 28 10 tags 10 hits First Stick: 13-mar-2006 08:04:13 First File: GRA06072.103 Last Stick: 13-mar-2006 08:06:11 Last File: GRA06072.103 GRA 03/13/06 Total: 80 03/13/2006 09:03 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/03/13 08:06:33 03/13/2006 09:03 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/03/13 08:05:28 03/08/2006 11:50 Troy A GMC was performed 3/8/06. All transcievers were checked for tune and no problems were found. A stick test was not conducted as Ken Thomas had performed on earlier in the week. Both gates at the adult trap are operating at 50 PSI. 03/07/2006 08:29 Alan_Bro Stick test from Ken Thomas PACIFIC STATES MARINE FISHERIES PIT Tag Database Stick Tag Summary Report By Site, Date and Coil (stick_tag_summary.rw) Mar 7, 2006 12:00:00 Page 1 03/06/06 GRA Coil 12 10 tags 10 hits 03/06/06 GRA Coil 14 10 tags 10 hits 03/06/06 GRA Coil 16 10 tags 10 hits 03/06/06 GRA Coil 18 10 tags 10 hits 03/06/06 GRA Coil 22 10 tags 10 hits 03/06/06 GRA Coil 24 10 tags 10 hits 03/06/06 GRA Coil 26 10 tags 10 hits 03/06/06 GRA Coil 28 10 tags 10 hits First Stick: 06-mar-2006 08:49:26 First File: GRA06065.103 Last Stick: 06-mar-2006 08:51:46 Last File: GRA06065.103 GRA 03/06/06 Total: 80 03/06/2006 09:04 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/03/06 08:52:00 03/06/2006 09:04 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/03/06 08:50:55 03/03/2006 15:24 alan@ruf 02:LowExcCurrent: This alarm was caused by PTAGIS Field Operations personnel during a site visit. 03/03/2006 12:11 Troy A site GMC was performed 3/3/06. All transcievers were checked for tune and no problems were found. 10 sticks were thrown on the East and West flumes. All were read and diverted properly. The water flow on the West side was a little low so sticks had trouble transitioning through the gate into the trap. DDS was in-advertantly turned on while trying to shut off SbyC due to a stick stuck in the gate. All the sticks were rescued from the recovery area. I would recommend throwing sticks on the West side prior to the East as they need all the boyancy they can get due to the lower flow. The gate pressure is set at 50 PSI on both gates. The report utility wasn't working on PC2 so a new one was brought down from the ftp site. PC2 is 29 Seconds behind atomic time PC1 is 34 Seconds behind atomic time SbyC Event On/Off for East and West was recorded properly into the raw file. 03/03/2006 12:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/03/03 11:32:52 03/03/2006 12:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/03/03 11:32:12 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/03 11:30:57 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/03 11:30:25 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/03 11:30:25 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/03 11:30:20 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/03 11:30:19 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/03 11:30:11 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/03 11:30:11 03/03/2006 12:05 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/03 11:30:07 03/03/2006 12:04 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/03/03 11:30:07 03/03/2006 12:04 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/03/03 11:28:57 03/03/2006 12:04 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2006/03/03 11:28:27 03/03/2006 12:04 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/03/03 11:28:26 03/03/2006 12:04 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2006/03/03 11:28:25 03/03/2006 12:04 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/03/03 11:21:15 03/02/2006 09:00 Don_Warf Site personnel report that the trap was put into operation at 10:00 yesterday morning. A GMC will be performed tomorrow. 03/01/2006 12:04 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/03/01 09:14:18 03/01/2006 12:04 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/03/01 09:14:12 03/01/2006 12:04 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2006/03/01 09:08:26 02/17/2006 16:42 Troy A waterup GMC was performed 2/17/06. All ladder transcievers were checked for tune. The trap is not yet active so those transcievers were not checked. No problems were found. The ladder was watered up around 2 pm. 02/17/2006 16:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/02/17 12:41:53 02/17/2006 16:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/02/17 12:28:21 02/17/2006 16:02 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/02/17 12:28:21 02/17/2006 16:02 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/02/17 12:28:20 02/17/2006 16:02 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/02/17 12:28:20 02/17/2006 16:02 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/02/17 12:24:46 02/17/2006 16:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/02/17 12:24:46 02/17/2006 16:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/02/17 12:24:41 02/17/2006 16:02 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/02/17 12:24:40 02/17/2006 16:02 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/02/17 12:24:39 02/17/2006 16:02 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/02/17 12:24:35 02/17/2006 16:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/02/17 12:23:59 02/17/2006 16:02 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/02/17 12:23:58 02/17/2006 16:02 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/02/17 12:23:49 02/17/2006 16:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/02/17 12:23:48 02/17/2006 16:02 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2006/02/17 12:23:42 02/17/2006 16:02 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2006/02/17 12:23:40 02/17/2006 16:02 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/02/17 12:23:39 02/17/2006 16:02 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2006/02/17 12:23:37 02/17/2006 16:02 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2006/02/17 12:23:35 02/17/2006 16:02 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/02/17 12:23:33 02/17/2006 16:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/02/17 12:14:49 02/17/2006 12:51 troy SbyC events are now recorded into the raw file for MM. File GRA0648.109 has examples of the exact text displayed. When SbyC is enabled and not in 100% sample or already in sample a message will be written to the raw file stating EAST SBYC EVENT ON when a fish with the proper action code is detected on the east flume. It will be followed with EAST SBYC EVENT OFF when the diversion time has expired. Same for the west flume. 02/17/2006 12:47 troy Upon arrival for a water up GMC it was found that the ladder has not watered up yet. Ken MacEntire informed me that a problem with Unit 5 at the dam pulled the water up crew from the task of watering up the ladder. He suspects Tuesday 2/21/06 to be the new water up date but suggested a call be placed prior to traveling to the site. 02/17/2006 12:04 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2006/02/17 11:28:51 02/17/2006 12:04 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2006/02/17 11:24:49 02/17/2006 08:02 troy@ruf 02:LowExcCurrent,06:LowExcCurrent,08:LowExcCurrent: These alarms will be addressed today. 02/15/2006 12:27 Darren_C All transceivers for the ladder and the trap were verified as being powered up and in a scan mode for detecting PITtag's. The site is scheduled to watered up tomorrow.. Darren R. Chase PSMFC Feild Systems Engineer (509) 735-2773 Ext.3 02/14/2006 18:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/02/14 17:49:08 02/14/2006 18:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/02/14 17:49:09 02/14/2006 18:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/02/14 17:49:08 02/14/2006 18:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/02/14 17:45:36 02/14/2006 18:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/02/14 17:45:36 02/14/2006 18:05 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/02/14 17:45:35 02/10/2006 12:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/02/10 09:28:53 02/10/2006 12:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/02/10 09:28:52 02/06/2006 03:03 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/02/06 02:21:09 02/06/2006 03:03 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/02/06 02:21:09 01/25/2006 18:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/01/25 17:30:31 01/25/2006 18:03 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/01/25 17:30:30 01/25/2006 18:03 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/01/25 17:30:30 01/25/2006 18:03 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/01/25 17:29:31 01/25/2006 18:03 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/01/25 17:29:31 01/25/2006 18:03 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/01/25 17:29:30 01/21/2006 03:08 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/01/21 02:45:22 01/21/2006 03:08 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/01/21 02:45:21 01/21/2006 03:08 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/01/21 02:45:21 01/21/2006 03:07 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/01/21 02:44:10 01/21/2006 03:07 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/01/21 02:44:10 01/21/2006 03:07 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/01/21 02:44:09 01/21/2006 00:05 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2006/01/20 21:24:24 01/21/2006 00:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/01/20 21:24:23 01/21/2006 00:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/01/20 21:24:23 01/21/2006 00:05 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/01/20 21:14:00 01/21/2006 00:05 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/01/20 21:14:00 01/21/2006 00:04 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2006/01/20 21:13:59 01/21/2006 00:04 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2006/01/20 21:13:59 01/21/2006 00:04 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2006/01/20 21:11:13 01/21/2006 00:04 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2006/01/20 21:11:13 01/21/2006 00:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2006/01/20 21:11:13 01/09/2006 12:23 Alan_Bro Multimon had stopped on PC1 with only a cryptic windows error to explain why. Files were submitted from PC2 to fill the gap. The clocks were set to within 1 second of atomic time and the files from 2005 were archived in their own folders on both PCs 01/05/2006 09:34 Darren_C The ladder has been confirmed as being de-watered on 1-3-06. The antennas were inspected on 1-4-06 by PSMFC with no problems reported. Darren R. Chase PSMFC Systems Engineer (509) 735-2773 ext.3 darren@psmfc.org 01/01/2006 12:40 PTOC_Bot Annual log file initiation for GRA #### End of Event Log for GRA ###