EVENT LOG FOR SITE GRA The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/26/2012 12:37 Troy@bay 03:TestTagFailure: Noted 12/21/2012 17:35 scottl Put ladder transceivers 3 through 8 into standby to avoid reciever massive amounts of e-mail alerts 12/19/2012 14:16 Scott_Li Turned OFF transceiver unresponsive alarm message 'SET =0' , via site configuration on PC2 for ladder transceivers 3 through 8. Transceivers 01 and 02 are 2020 units and will retune to the dry ladder conditions and conversely when the ladder waters up. PC1 was already set to zero as expected I guess. By doing this, it allows the units to remain in read mode in case the ladder waters up unexpectedly. 12/19/2012 09:04 rclark@b 03:TestTagFailure: The ladder is down for the season. In order to reduce the number of M4 alerts on transceivers 03 through 08, these transceivers have been placed in standby operation. Transceivers 01 and 02 are 202 transceivers and were left in normal operation. The transceivers will be returned to normal operational mode when the ladder is watered back up. 12/19/2012 07:25 Alan Mike Halter reports that the ladder dewatered (~0800-PST) 12/18/2012. Estimated return to service is the end of February 2013. 12/14/2012 07:33 alan@bay 07:TestTagFailure: This transceiver appears to have drifted slightly out of tune but is reading PIT tags well. This will be investigated during the next site visit. 12/07/2012 11:29 Nicole Removed data reported in GRA12340.203 from database. It was inadvertently submitted and duplicated data in GRA12340.103. 12/06/2012 12:19 Scott_Li Replaced the power supply in PC1. This PS had been previously replaced so the after market supplies are not very reliable. Submitted GRA12340.103 and GRA12340.203 through GRA12341.206. The 340.103 and 340.203 are duplicate files. Inadvertently submitted the .203 file, assume that DB will kick it out and not process due to this. No other problems to report. Clocks are within with in 2 seconds of each other. 12/05/2012 10:54 Alan PC1 is currently down. PC2 has been confirmed to be collecting data. We are working to get the platform back to functional, more information to come. 12/05/2012 07:50 Troy Manually pushed the 5 deliquent M4 files. PSMFC will monitor to see if files continue to load or not. If not then the upload service will be re- started. 12/04/2012 06:58 rclark@b 05:TestTagFailure: Transceiver was retuned on 12/3/2012. 12/03/2012 10:49 Roger Performed site GMC on 12/3/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 9 seconds behind atomic time. PC2 was 90 seconds behind atomic time and was adjusted to within 1 second of PC1. Files on PC2 were archived. There are no problems to report. 12/02/2012 09:37 troy@bay 05:TestTagFailure: This alarm will be address on the next site visit. 12/01/2012 07:52 troy@bay 05:TestTagFailure: This alarm will be addressed on the next site visit. 11/29/2012 08:01 Troy@bay 03:TestTagFailure: This alarm will be addressed on the next site visit. 11/28/2012 08:14 Troy@bay 03:TestTagFailure: This will be addressed on the next site visit. 11/27/2012 07:12 scottl@b 03:ReaderReset,04:ReaderReset,05:ReaderReset,06:InputSyncDetect,06:ReaderR eset,07:ReaderReset,08:ReaderReset,08:RocketPortNoEOT,12:ReaderReset,14:In putSyncDetect,14:ReaderReset,16:InputSyncDetect,16:ReaderReset,18:InputSyn cDetect,18:ReaderReset,22:InputSyncDetect,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:ReaderReset: Temporary Power outage 2012/11/26 07:30:51 --> set to 'ON' 2012/11/26 07:28:48 --> set to 'OFF' 11/26/2012 12:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/11/26 07:30:51 11/26/2012 12:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/11/26 07:28:48 11/26/2012 07:53 Troy@bay 05:TestTagFailure: This will be investitgated on the next site visit. 11/25/2012 08:16 rclark@b 05:TestTagFailure: This will be addressed during the next site visit. 11/24/2012 08:38 rclark@b 05:TestTagFailure: This will be addressed during the next site visit. 11/23/2012 08:58 rclark@b 05:TestTagFailure: This will be addressed during the next site visit. 11/22/2012 07:55 rclark@b 05:TestTagFailure: This will be addressed during the next site visit. 11/20/2012 07:07 Rclark@b 05:TestTagFailure: This will be addressed during the next site visit. 11/19/2012 11:31 Troy Upgraded the M4 machines to M4 ver 1.4.7 (x64). 11/19/2012 09:01 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/11/19 06:45:18 11/19/2012 09:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/11/19 06:45:16 11/19/2012 09:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/11/19 06:45:16 11/19/2012 09:01 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2012/11/19 06:44:04 11/19/2012 08:51 Don_Warf Site Bio reports: We shut the trap down right after the 0645 sample this morning. We will try to start trapping again on March 1, 2013. It is possible that because of budget cuts we will operate the trap Monday through Friday in the spring and summer. When August 18th comes around, we would go back to seven days a weeks. 11/18/2012 07:56 alan@bay 05:TestTagFailure: This will be addressed during the next site visit. 11/17/2012 07:03 alan@bay 05:TestTagFailure: This will be addressed during the next site visit. This transceiver is reading PIT tags with high efficiency. 11/16/2012 07:52 alan@bay 05:TestTagFailure: This will be addressed during the next site visit. 11/12/2012 08:14 darren@b 05:TestTagFailure: This detection system will be adjusted during the next site visit. 11/10/2012 07:24 darren@b 05:TestTagFailure: The noise on this system has increased slightly and will be addressed during the next site visit. 11/08/2012 16:07 Scott_Li Per Darren Ogden.. I just wanted to information you that the Lower Granite Dam adult fish trap will be shutting down on Monday, November 19, 2012, in the morning. Please pass this information on to those who need to know from your organization. 11/08/2012 14:51 Don_Warf From NMFS operators: I just wanted to information you that the Lower Granite Dam adult fish trap will be shutting down on Monday, November 19, 2012, in the morning. Please pass this information on to those who need to know from your organization. 11/08/2012 14:29 Troy This site's M4 PCs were upgraded from M4 1.4.4x64 to M4 1.4.6x64. PC2 was upgraded first and if there is a need to patch data it can be found in GRA-2012-313-S-015.xml 11/01/2012 10:11 Darren A site GMC was performed today (11-1-12). All transceivers were checked and adjusted for tuning, noise, and detectability. The PC clocks are within 20 seconds of atomic time and each other. No problems were discovered during this visit. 10/30/2012 13:49 Troy M4 v1.4.4 was installed on PC1 and PC2, siteconfig files were emailed to portland for proper archival. Comm's and cluter fail over was tested. No problem to report. 10/28/2012 09:23 troy@bay 05:TestTagFailure: This will be addressed on the next site visit. 10/28/2012 09:10 Troy PC1 and PC2 was accessed and Multimon was stopped and restarted for DST. All files were archived on PC2 and the files on PC1 were uploaded and archived. The .105/205 file is the first file at the correct time. 10/27/2012 07:14 troy@bay 03:TestTagFailure,05:TestTagFailure: These alarms will be addressed on the next site visit. 10/26/2012 08:55 Nicole Updated Multimon database to GRA12300.DB, which includes additional tag codes for ACs 15, 70, and 71. Reset PC2 clock to within one second of atomic and PC1 clock; it was 22 seconds behind. Uploaded GRA12300.205 as gap file. Observed many excessive noise alarms for 05. 10/26/2012 06:25 scottl@b 03:TestTagFailure: Noted , will adjust on the next visit. 10/26/2012 06:23 scottl@b 05:TestTagFailure: Unit is out of tune, will adjust on the next site visit. 10/25/2012 06:43 darren@b 03:TestTagFailure,05:TestTagFailure,SLC500:CommsFailure: The SLC error is not uncommon. The alarms on 03 and 05 will be investitgated during the next site visit. It appears that the noise has slightly elevated and systems will need to be re-tuned. 10/24/2012 10:31 Troy@bay 05:TestTagFailure: This alarm will be addressed on the next site visit. 10/24/2012 06:28 Alan Manually pushed M4 file GRA-2012-297-P-015.xml to thanos where it sucessfully loaded. 10/23/2012 07:01 Troy@bay 05:TestTagFailure: This transceiver appears to have de-tuned. It will be addressed on the next GMC. It's CEA report readign is currently at 100%. 10/22/2012 06:51 Alan Manually pushed M4 files GRA-2012-293-P-014.xml and GRA-2012-295-P- 014.xml to thanos where they sucessfully loaded. 10/17/2012 08:26 Nicole Updated Multimon database file to GRA12291.DB, which includes additional tag codes for ACs 15, 70, and 71. PC2 clock was 14 seconds behind PC1 and atomic time; it was reset to be within one second. Uploaded GRA12291.205 as gap file. 10/16/2012 14:50 Rclark@b 03:ReaderReset,04:ReaderReset,05:ReaderReset,06:InputSyncDetect,06:ReaderR eset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,12:ReaderReset,14:In putSyncDetect,14:ReaderReset,16:InputSyncDetect,16:ReaderReset,18:InputSyn cDetect,18:ReaderReset,22:InputSyncDetect,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:ReaderReset: Caused by power outage. AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/10/16 09:47:05 AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/10/16 10:06:47 10/16/2012 12:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/10/16 10:06:47 10/16/2012 12:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/10/16 09:47:05 10/11/2012 08:28 Nicole Updated Multimon database file to GRA12285.DB, which includes additional tag codes for ACs 15, 70, and 71. PC1 and PC2 clocks were 3 and 14 seconds behind atomic time. They were reset to be within one second of each other and atomic time. Uploaded GRA12285.205 as gap file. 10/09/2012 10:10 scottl Removed the M4 platform network connection from the SW and and relocated it to the BB network switch inside the FG cabinet. This will eliminate the lost connection from M4 to the PLC in the event of a SW outage. 10/08/2012 09:43 Roger Performed site GMC on 10/8/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 2 seconds and PC2 is 7 seconds behind atomic time. Files on PC2 were archived. The supply locker was restocked. There are no problems to report. 10/08/2012 07:02 Alan Manually pushed M4 files GRA-2012-280-P-017.xml and GRA-2012-281-P- 008.xml to thanos where they sucessfully loaded. 10/08/2012 06:22 darren@b SLC500:CommsFailure: Alarm has been noted. 10/07/2012 15:01 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2012/10/07 14:57:30 10/07/2012 15:01 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2012/10/07 14:57:30 10/07/2012 15:01 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2012/10/07 14:57:30 10/07/2012 15:01 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2012/10/07 14:57:30 10/06/2012 09:59 scottl@b 05:TestTagFailure,SLC500:CommsFailure: Noted 10/05/2012 09:11 Rclark@b 05:TestTagFailure: A tagged fish was in the antenna field when the timer tag fired. 10/04/2012 16:53 Nicole Updated Multimon database file to GRA12278.DB, which includes additional tags for ACs 15, 70, and 71. PC2 clock was 19 seconds behind atomic time. It was reset to be within one second of atomic time and PC1 clock. Upload GRA12278.208 as gap file. 10/03/2012 06:14 Alan Manually pushed GRA-2012-276-P-011.xml to thanos where it sucessfully loaded. 09/29/2012 09:36 alan@bay SLC500:CommsFailure: Not uncommon in times of high traffic. PTAGIS Field Operations will continue to monitor. 09/27/2012 06:42 Rclark@b SLC500:CommsFailure: Common error during periods of high fish traffic. 09/26/2012 10:36 Nicole Updated Multimon database file to GRA12270.DB, which includes additional tag codes for ACs 15, 70, and 71. PC1 and PC2 clocks were 2 and 16 seconds behind atomic time. They were reset to be within one second of each other and atomic time. Uploaded GRA12270.206 as gap file. I saw a SLC 500 Comms error occur during a default diversion away from trap. This was not associated with switching control between PC1 and PC2. 09/26/2012 07:17 alan@bay SLC500:CommsFailure: Not uncommon during periods of high fish traffic. Clearing TASS. 09/24/2012 07:22 alan@bay SLC500:CommsFailure: The failure will be investigated during the next site visit. This alarm is not uncommon during high traffic times. PSMFC will continue to monitor for future alarms. 09/23/2012 06:52 rclark@b SLC500:CommsFailure: This alarm is not uncommon during periods of high fish traffic. 09/22/2012 06:49 rclark@b SLC500:CommsFailure: Not uncommon during periods of high fish traffic. Clearing TASS. 09/20/2012 06:42 darren@b SLC500:CommsFailure: The failure will be investigated during the next site visit. This alarm is not uncommon during high traffic times. PSMFC will continue to monitor for future alarms. 09/19/2012 09:57 Nicole Updated Multimon database file to GRA12263.DB, which includes additional tag codes for ACs 15, 70, and 71. PC1 and PC2 clocks were 3 and 16 seconds behind atomic time. They were reset to be within one second of each other and atomic time. Uploaded GRA12263.207 as gap file. 09/15/2012 08:03 Troy M4 was restarted at the top of the hour to better sync with reports such as DGE. 09/15/2012 06:55 troy@bay 03:ReaderReset,03:TestTagFailure,04:InputSyncDetect,04:ReaderReset,04:Rock etPortNoEOT,05:ReaderReset,06:InputSyncDetect,06:ReaderReset,06:RocketPort NoEOT,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,08:RocketPortNoEOT, 12:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Rea derReset,18:InputSyncDetect,18:ReaderReset,22:InputSyncDetect,22:InputSync Lost,22:ReaderReset,24:InputSyncDetect,24:InputSyncLost,24:ReaderReset,26: InputSyncDetect,26:InputSyncLost,26:ReaderReset,28:InputSyncDetect,28:Inpu tSyncLost,28:ReaderReset,SLC500:CommsFailure: These alarms are the result of several planned power outages by the COE. 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 17:28:15 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 17:22:01 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 17:21:16 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 17:19:11 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 17:13:11 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 17:10:26 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 17:05:13 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 16:57:48 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 16:52:54 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 16:50:52 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 16:49:40 09/13/2012 18:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 16:44:44 09/13/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/09/13 13:25:49 09/13/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/09/13 13:23:49 09/13/2012 11:20 Alan A GMC was performed 9-13-2012. All transceivers were checked and tuned as necessary. Both PCs are within one second of atomic time. Outstanding files on PC2 were archived. No problems found. 09/13/2012 08:07 Nicole Updated Multimon database file to GRA12257.DB, which includes additional tag codes for ACs 15, 70, and 71. PC1 and PC2 clocks are 2 and 14 seconds behind atomic time. Uploaded GRA12257.205 as gap file. 09/12/2012 15:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/09/12 14:22:20 09/12/2012 15:01 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/09/12 12:34:33 09/12/2012 07:08 Troy@bay 03:TestTagFailure: Noted 09/11/2012 09:01 DGE_Robo B_DivertDuringSample (B_DDSample) changed from 'ON' to 'OFF' at 2012/09/11 06:57:57 09/11/2012 09:01 DGE_Robo A_DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2012/09/11 06:57:57 09/11/2012 06:30 Troy@bay 03:TestTagFailure: Noted 09/10/2012 18:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/09/10 15:08:34 09/10/2012 18:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/09/10 15:08:33 09/10/2012 18:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/09/10 15:08:11 09/10/2012 18:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/09/10 15:08:11 09/10/2012 18:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/09/10 15:08:10 09/10/2012 18:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/09/10 15:08:09 09/10/2012 18:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/09/10 15:08:08 09/10/2012 18:01 DGE_Robo B_DivertDuringSample (B_DDSample) changed from 'OFF' to 'ON' at 2012/09/10 15:08:06 09/10/2012 18:00 DGE_Robo A_DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2012/09/10 15:08:06 09/10/2012 15:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/09/10 12:44:45 09/10/2012 15:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/09/10 12:44:44 09/10/2012 15:00 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/09/10 12:29:22 09/10/2012 12:01 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2012/09/10 10:29:01 09/10/2012 12:01 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2012/09/10 10:29:01 09/10/2012 08:17 Troy M4 was changed to 60 min files and uploads every 30 mins. This was done on the 1/2. 09/07/2012 14:32 darren@b SLC500:CommsFailure: Alarm generated by PSMFC personnel. 09/07/2012 13:15 Nicole Updated Multimon database file to GRA12251.DB, which includes additional tag codes for ACs 15, 70, and 71. PC2 clock was 26 seconds behind PC1 and atomic time; it was reset to be within one second of PC1 and atomic time. Uploaded GRA12251.208 as gap file. My activities resulted in a SLC Comms error on PC1. 09/05/2012 09:17 Troy M4 was given control of the gates at 10:00 PDT. PSMFC will continue to monitor the performance of M4. Site personnel were informed of the change and are aware of the H O A switch and how it works. 09/04/2012 09:18 Nicole Updated Multimon database file to GRA12248.DB, which includes additional tag codes for ACs 15, 70, and 71. PC1 clock is within 1 second of atomic time. PC2 clock is 19 seconds behind atomic time. Uploaded GRA12248.206 as gap file. 09/04/2012 07:01 Troy Site was spot checked against MM and M4 counts in the PLC match that of MM. 09/02/2012 06:44 Alan Manually sent the M4 files GRA-2012-245-P-038.xml and 039.xml to PTAGIS through the M4 Upload/Archive utility. 08/28/2012 12:01 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2012/08/28 10:50:18 08/28/2012 11:01 Troy M4 PC1 and M4 PC2 came online today. M4 PC1 was loaded with the proper SbyC protocols and is communicating with the PLC. They are running in the background. Multimon still has control of the gates. M4 will be monitored for a period of time before it is given control of the gates. The site started trapping at 0700. The switch that provides indication did not engage at that time. PSMFC personnel engaged the switch. This switch may need adjustment. No other problems to report. 08/28/2012 06:57 alan@bay 26:InputSyncDetect: This will be investigated during the next site visit. 08/28/2012 06:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/08/28 05:58:51 08/28/2012 06:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/08/28 05:58:50 08/28/2012 06:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/08/28 05:58:50 08/27/2012 08:02 Nicole Updated Multimon database file to GRA12240.DB, which includes additional tag codes for ACs 15, 70, and 71 (D. Marsh's adult fall Chinook). PC1 and PC2 clocks were 2 and 21 seconds behind atomic time; they were reset to be within one second of each other and atomic time. Uploaded GRA12240.206 as gap file. 08/24/2012 06:43 alan@bay 26:InputSyncLost: This one-time alarm will be investigated during the next site visit. 08/23/2012 15:01 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/08/23 13:09:53 08/23/2012 15:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 13:01:37 08/23/2012 15:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 13:01:36 08/23/2012 15:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/08/23 13:01:32 08/23/2012 15:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/08/23 13:01:28 08/23/2012 15:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/08/23 13:01:25 08/23/2012 15:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/08/23 13:01:23 08/23/2012 15:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 13:01:21 08/23/2012 15:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 13:01:20 08/23/2012 15:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/08/23 13:01:19 08/23/2012 15:01 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/08/23 13:01:17 08/23/2012 15:01 DGE_Robo B_DivertDuringSample (B_DDSample) changed from 'ON' to 'OFF' at 2012/08/23 13:01:16 08/23/2012 15:01 DGE_Robo A_DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2012/08/23 13:01:16 08/23/2012 15:01 DGE_Robo B_DivertDuringSample (B_DDSample) changed from 'OFF' to 'ON' at 2012/08/23 13:01:15 08/23/2012 15:01 DGE_Robo A_DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2012/08/23 13:01:15 08/23/2012 15:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 12:53:27 08/23/2012 15:01 DGE_Robo B_DivertDuringSample (B_DDSample) changed from 'ON' to 'OFF' at 2012/08/23 12:53:26 08/23/2012 15:01 DGE_Robo A_DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2012/08/23 12:53:26 08/23/2012 15:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/08/23 12:53:25 08/23/2012 15:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 12:53:24 08/23/2012 15:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/08/23 12:53:22 08/23/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/08/23 12:20:18 08/23/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/08/23 12:18:18 08/23/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/08/23 12:17:13 08/23/2012 15:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/08/23 12:17:03 08/23/2012 15:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/08/23 12:17:01 08/23/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/08/23 12:15:14 08/23/2012 12:56 Alan Text from xcvr 01 (FS2020) causd the sys event alerter to reject GRA12236.104. The offending lines were removed and the file was sucessfully re-submitted. 08/23/2012 12:49 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/08/23 11:35:32 08/23/2012 12:49 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/08/23 11:35:31 08/23/2012 12:49 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/08/23 11:32:00 08/23/2012 12:49 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/08/23 11:31:59 08/23/2012 12:49 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/08/23 11:29:37 08/23/2012 12:49 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/08/23 11:29:36 08/23/2012 12:49 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/08/23 11:24:26 08/23/2012 12:49 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/08/23 11:24:25 08/23/2012 12:49 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 11:24:09 08/23/2012 12:49 DGE_Robo B_DivertDuringSample (B_DDSample) changed from 'OFF' to 'ON' at 2012/08/23 11:24:00 08/23/2012 12:49 DGE_Robo A_DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2012/08/23 11:24:00 08/23/2012 12:49 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/08/23 11:23:59 08/23/2012 12:49 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 11:23:46 08/23/2012 12:49 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 11:23:39 08/23/2012 12:49 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 11:23:37 08/23/2012 12:49 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 11:23:27 08/23/2012 12:49 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 11:23:26 08/23/2012 12:49 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 10:36:09 08/23/2012 12:49 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/08/23 10:36:09 08/23/2012 12:49 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 10:31:53 08/23/2012 12:49 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/08/23 10:31:50 08/22/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/08/22 13:10:01 08/22/2012 15:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/08/22 13:08:01 08/21/2012 06:45 darren@b 16:InputSyncDetect,16:ReaderReset: Alarm caused by a reader reset. 08/18/2012 08:28 Troy@bay 26:InputSyncDetect: Noted 08/18/2012 06:57 Nicole Updated Multimon database and map file to GRA12230.DB and GRA12231.MAP. These files contain tag codes and instructions for ACs 15,70, and 71 (D. Marsh's adult fall Chinook). PC1 and PC2 clocks were 15 seconds ahead and 23 seconds behind atomic time. They were reset to be within one second of each other and atomic time. Uploaded GRA12231.205 as gap file. 08/16/2012 09:23 Troy@bay 26:InputSyncLost: Noted 08/15/2012 06:11 Rclark@b 26:BadOscFreq,26:InputSyncDetect,28:InputSyncDetect,28:InputSyncLost: Remoted in on 8/14/2012 to clear Bad Osc Freq error on transceiver 26. 08/14/2012 06:33 Troy@bay 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:BadOscFreq,26:InputSyncDetect,26:InputSyncLost,26:Read erReset,28:InputSyncDetect,28:InputSyncLost,28:ReaderReset: These alarms caused by a power outage: AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/08/14 05:02:51 AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/08/14 05:06:03 08/14/2012 06:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/08/14 05:06:43 08/14/2012 06:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/08/14 05:03:31 08/12/2012 15:01 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2012/08/12 13:54:07 08/12/2012 15:01 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2012/08/12 13:54:06 08/12/2012 09:00 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/08/12 06:07:31 08/12/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/08/12 06:07:29 08/12/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/08/12 06:07:28 08/09/2012 09:00 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/08/09 07:34:52 08/09/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/08/09 07:34:51 08/09/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/08/09 07:34:51 08/06/2012 09:53 Roger Performed site GMC on 8/6/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 18 seconds ahead of atomic time. PC2 is 6 seconds ahead of atomic time. Files on PC2 were archived. There are no problems to report. 08/06/2012 06:00 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/08/06 05:58:29 08/05/2012 09:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/08/05 06:03:46 08/05/2012 09:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/08/05 06:03:45 08/01/2012 09:57 Roger Performed site GMC on 8/1/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 18 seconds ahead of atomic time. PC2 was 7 seconds behind atomic time and was adjusted to within 1 second of PC1. Files on PC2 were archived. There are no problems to report. 07/30/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/07/30 06:29:32 07/30/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/07/30 06:29:32 07/30/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/07/30 06:22:35 07/30/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/07/30 06:22:35 07/30/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/07/30 06:14:35 07/30/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/07/30 06:14:34 07/27/2012 09:00 DGE_Robo TrapGate (Trap) changed from 'OPEN' to 'CLOSED' at 2012/07/27 07:12:12 07/26/2012 09:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/07/26 06:10:40 07/26/2012 09:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/07/26 06:10:40 07/26/2012 05:57 darren@b 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:BadOscFreq,26:InputSyncDetect,26:LowExcCurrent,26:Read erReset,28:InputSyncDetect,28:LowExcCurrent,28:ReaderReset: Site power outage. 07/25/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/25 19:18:50 07/25/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/25 19:16:48 07/25/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/25 19:14:55 07/25/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/25 19:12:54 07/25/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/25 19:09:46 07/25/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/25 19:06:06 07/25/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/25 19:02:12 07/25/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/25 19:00:10 07/25/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/25 18:58:07 07/25/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/25 18:47:36 07/25/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/25 18:23:32 07/25/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/25 18:00:11 07/19/2012 14:17 Rclark@b 26:BadOscFreq,26:LowExcCurrent,26:ReaderReset,28:BadOscFreq,28:InputSyncDe tect,28:InputSyncLost: Transceiver 28 was remotely reset to clear BadOscFreq error. 07/19/2012 13:17 Troy The mail server address was successfully changed and tested for the HMI's at this site. 07/19/2012 09:21 Nicole Updated Multimon database file to GRA12201.DB, which includes additional tags for AC 12 (J. Cassinelli's jaw tag fish). PC1 and PC2 clocks are 21 and 24 seconds ahead of atomic time. Uploaded GRA12201.207 as patch file. 07/19/2012 09:00 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/07/19 06:43:36 07/19/2012 09:00 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/07/19 06:43:36 07/19/2012 09:00 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/07/19 06:40:40 07/19/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/07/19 06:40:40 07/19/2012 09:00 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/07/19 06:40:39 07/19/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/07/19 06:40:39 07/19/2012 07:28 alan@bay 26:BadOscFreq,26:LowExcCurrent,28:InputSyncDetect,28:InputSyncLost: This will be investigated during the next site visit. These xcvrs are reading PIT tags with a high efficiency. 07/18/2012 10:05 alan@bay 28:InputSyncDetect,28:InputSyncLost: Caused by power outage? PTAGIS Field Operations will continue to monitor. 07/18/2012 09:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/07/18 06:42:05 07/18/2012 09:00 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/07/18 06:42:05 07/18/2012 08:47 alan@bay 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:InputSyncLost,26:ReaderReset,28:Inp utSyncDetect,28:InputSyncLost,28:ReaderReset: Alarms are the result of power outages. 07/17/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/17 19:54:57 07/17/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/17 19:31:51 07/17/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/17 19:29:25 07/17/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/17 19:05:08 07/17/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/17 19:01:05 07/17/2012 21:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/17 18:41:15 07/17/2012 18:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/07/17 17:54:54 07/17/2012 18:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/07/17 17:47:48 07/17/2012 06:41 Don_Warf The COE reports that multiple power outages will occur today between 1700 and 1900 hours PDT. 07/14/2012 10:01 scottl@b 26:LowExcCurrent,28:LowExcCurrent: Noted 07/09/2012 13:40 Nicole Updated Multimon database file to GRA12191.DB, which includes additional tags for AC 12 (J. Cassinelli's jaw tags). PC1 and PC2 clocks are 23 and 22 seconds ahead of atomic time, respectively. PTTP was not running on PC1; backlogged files (back to GRA12190.108) were submitted. GRA12191.208 was submitted from PC2 as patch file. 07/09/2012 11:15 rclark@b 26:BadOscFreq,26:InputSyncDetect,28:InputSyncDetect,28:InputSyncLost: Power was cycled on transceiver 26 to clear bad osc error. The sync was OK while on site. Will continue to monitor. 07/09/2012 10:39 Roger Performed site GMC on 7/9/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 23 seconds ahead of atomic time. PC2 was 5 seconds behind atomic time and was adjusted to within 1 second of PC1. Files on PC2 were archived. There are no problems to report. 07/05/2012 10:06 scottl Changed DNS entries on all data collection computers including the utility pc's in prep for the network change over and as requested by Todd and Chris. PC1 at GRA initially required the Win 98 CD to be installed but with some fanagaling was able to get the PC configured. Still need to replace the CDROM drive in PC1 07/02/2012 06:22 darren@b 28:InputSyncDetect,28:InputSyncLost: Alarms will be investigated during the next site visit. 07/01/2012 07:12 Troy@bay 28:InputSyncDetect,28:InputSyncLost: Possible Random Reader Reset, PSMFC will monitor. 06/30/2012 06:40 Troy@bay 28:InputSyncDetect,28:InputSyncLost: Random Reader Reset 06/29/2012 06:25 Rclark@b 26:InputSyncLost,28:InputSyncDetect,28:InputSyncLost: This will be addressed during the next site visit. 06/28/2012 06:56 Troy@bay 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:InputSyncDetect,28:R eaderReset: These are the result of a power outage. AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/06/28 05:12:06 AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/06/28 05:14:07 06/28/2012 06:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/06/28 05:14:51 06/28/2012 06:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/06/28 05:12:51 06/26/2012 10:32 Nicole Updated Multimon database file to GRA12178.DB, which includes additional tag codes for AC 12 (J. Cassinelli's jaw tag fish). PC1 clock was 6 seconds ahead and PC2 was 7 seconds behind atomic time; they were reset to be within one second of each other and atomic time. Uploaded GRA12158.206 as patch file. 06/25/2012 10:15 Roger Performed site GMC on 6/25/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 7 seconds ahead and PC2 is 4 seconds behind atomic time. Files on PC2 were archived. There are no problems to report. 06/20/2012 10:25 Alan A GMC was performed 6-20-2012. All transceivers were checked and tuned as necessary. Both PCs are seven seconds ahead of atomic time. Outstanding files on PC2 were archived. No problems found. 06/18/2012 15:24 Alan Updated Multimon database file to GRA12170.DB, which contains additional tag codes for AC-12. PC1 clock was 10 seconds behind atomic time, PC2 clock was 15 seconds behind atomic time. Both PCs were reset to be within one second of PC1 and atomic time. Uploaded GRA12170.208 as patch file. 06/15/2012 18:29 Alan Updated Multimon database file to GRA12167.DB. This file removes all tag codes for AC 11, M. Biggs's Lemhi Chinook. PC1 clock was within one second of atomic time, while PC2 clock was 20 seconds behind atomic time. PC2 was reset to be within one second of PC1 and atomic time. Uploaded GRA12167.209 as patch file. 06/11/2012 09:37 Roger Performed site GMC on 6/11/2012. All transceivers were checked for tune and adjusted as needed. PC1 is within 1 second of atomic time. PC2 is 9 seconds behind atomic time. Files on PC2 were archived. There are no problems to report. 06/08/2012 06:28 scottl@b 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:InputSyncDetect,28:R eaderReset: Power outage 2012/06/07 19:03:45 --> set to 'ON' 2012/06/07 19:01:42 --> set to 'OFF' 2012/06/07 18:57:41 --> set to 'ON' 06/07/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/06/07 19:03:45 06/07/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/06/07 19:01:42 06/07/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/06/07 18:57:41 06/07/2012 21:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/06/07 18:55:29 06/07/2012 08:21 Nicole Updated Multimon database file to GRA12159.DB, which included additional tag codes for AC 12 (J. Cassinelli's jaw tag Chinook). PC1 clock was within one second of atomic time, while PC2 clock was 12 seconds behind atomic time. PC2 was reset to be within one second of PC1 and atomic time. Uploaded GRA12159.205 as patch file. Transceiver 01 is producing lots of tuning alarms. 06/05/2012 09:29 Roger Performed site GMC on 6/5/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 2 seconds ahead and PC2 is 7 seconds behind atomic time. Files on PC2 were archived. There are no problems to report. 06/02/2012 07:48 alan@bay 26:BadOscFreq,26:InputSyncLost,26:LowExcCurrent,28:BadOscFreq,28:InputSync Detect,28:InputSyncLost: Possible reader reset. Will continue to monitor. 06/01/2012 12:23 Nicole Updated Multimon database file to GRA12153.DB, which includes additional tag codes for AC-12 (J. Cassinelli's jaw tag fish). PC1 and PC2 clocks were 3 and 19 seconds behind atomic time, respectively; they were reset to be within one second of each other and atomic time. Uploaded GRA12153.207 as patch file. 05/30/2012 08:38 alan@bay 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:InputSyncDetect,28:R eaderReset: These alarms were caused by a short duration power outage. 05/29/2012 09:41 Roger Performed site GMC on 5/29/2012. All transceivers were checked for tune and adjusted as needed. PC1 is within 1 second of atomic time. PC2 is 9 seconds behind atomic time. Files on PC2 were archived. There are no problems to report. 05/29/2012 09:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/05/29 06:45:00 05/29/2012 09:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/05/29 06:43:00 05/25/2012 14:07 Nicole Updated Multimon database file to GRA12146.DB, which includes additional tag codes for AC-12 (J. Cassinelli's jaw tag fish). PC1 and PC2 clocks were 2 and 18 seconds behind atomic time; they were reset to be within one second of each other and atomic time. Uploaded GRA12146.207 as patch file. 05/25/2012 06:47 dlwarf@b 12:TestTagFailure: Noted. 05/25/2012 06:47 dlwarf@b 03:TestTagFailure: Noted. 05/21/2012 09:44 Roger Performed site GMC on 5/21/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 1 second behind atomic time. PC2 is 9 seconds behind atomic time. Filed on PC2 were archived. There are no problems to report. 05/21/2012 06:45 Rclark@b 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:InputSyncDetect,28:R eaderReset: Temporary power outage. 05/21/2012 06:00 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/05/21 04:32:33 05/21/2012 06:00 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/05/21 04:30:33 05/18/2012 14:44 Nicole Updated Multimon database file to GRA12139.DB, which includes additional tag codes for AC 12. PC1 clock was 22 seconds ahead of atomic time, while PC2 was 15 seconds behind. They were reset to be within one second of each other and atomic time. Uploaded GRA12139.208 as patch file. 05/18/2012 11:09 Alan PC1 was rebooted at ~10:45PST to re-establish PCA connectivity. File GRA12139.204 was submitted to fill the gap during PC1s downtime. 05/14/2012 10:15 Roger Performed site GMC on 5/14/2012. All transceivers were checked for tune and adjusted as needed. PC1 is within 1 second of atomic time. PC2 is 6 seconds behind atomic time. Files on PC2 were archived. A locker inventory was taken. Land-line phones were removed from the PIT tag room. There are no problems to report. 05/11/2012 09:00 Nicole Updated MultiMon database file to GRA12132.206, which includes additional tag codes for AC 12 (J. Cassinelli's jaw tag Chinook). PC1 and PC2 clocks were 4 and 24 seconds behind atomic time, respectively. They were reset to be within one second of each other and atomic time. Uploaded GRA12132.205 as patch file. 05/07/2012 09:44 Roger Performed site GMC on 5/7/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 2 seconds behind atomic time. PC2 is 2 seconds behind atomic time. Files on PC2 were archived. There are no problems to report. 05/04/2012 12:43 Nicole Updated MultiMon database file to GRA12125.DB, which includes additional tag codes for AC-12 (J. Cassinelli's jaw tag Chinook). PC1 and PC2 clocks are 2 and 7 seconds behind atomic time, respectively. Uploaded GRA12125.206 as patch file. 05/03/2012 07:12 alan@bay 03:ReaderReset,04:InputSyncDetect,04:ReaderReset,05:ReaderReset,06:InputSy ncDetect,06:ReaderReset,07:ReaderReset,08:InputSyncDetect,08:ReaderReset,1 2:ReaderReset,14:InputSyncDetect,14:ReaderReset,16:InputSyncDetect,16:Read erReset,18:InputSyncDetect,18:ReaderReset,22:ReaderReset,24:InputSyncDetec t,24:ReaderReset,26:InputSyncDetect,26:ReaderReset,28:InputSyncDetect,28:R eaderReset: Alarms the result of a short duration power outage. 05/03/2012 06:01 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/05/03 04:37:03 05/03/2012 06:01 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/05/03 04:35:03 05/02/2012 10:00 Roger Performed site GMC on 5/2/2012. All transceivers were checked for tune and adjusted as needed. The exciter current alarm on 01 and 02 was set to 3.4A (previously was at the default of 1.0 A). The noise alarm level was set to 30% (previously was at the default level of 50%). PC1 and PC2 are 2 seconds behind atomic time. Files on PC2 were archived. There are no problems to report. 05/01/2012 08:37 Nicole Updated MultiMon database file to GRA12122.DB, which includes additional tag codes for AC-12 (J. Cassinelli's Chinook). PC1 clock was 1 second behind atomic, PC2 was 14 seconds behind. PC2 was reset to be within one second of PC1 and atomic time. Uploaded GRA12122.204 as patch file. 04/27/2012 12:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/04/27 10:41:35 04/27/2012 12:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/04/27 10:41:35 04/27/2012 12:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/04/27 10:41:34 04/27/2012 12:01 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/04/27 09:57:01 04/27/2012 12:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/04/27 09:57:00 04/27/2012 12:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/04/27 09:57:00 04/26/2012 09:44 Roger Performed site GMC on 4/26/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 1 second ahead of atomic time. PC2 is 1 second behind atomic time. Files on PC2 were archived. There are no problems to report. 04/26/2012 07:06 Troy@bay 04:RocketPortNoEOT: PSMFC will monitor for future occurances of this alarm. 04/25/2012 08:27 Nicole Updated MultiMon database to GRA12116.DB, which includes additional tag codes for AC-12. PC1 and PC2 clocks were 3 and 13 seconds behind atomic time; they were reset to be within one second of each other and atomic time. Uploaded GRA12116.205 as patch file. 04/20/2012 08:37 Nicole Updated MultiMon database and map files to GRA12111.DB and GRA12111.MAP, respectively. These files contain instructions and tag codes for AC-12 (J. Cassinelli's returning adult Chinook). PC clocks were 5 and 26 seconds behind atomic time; they were reset to be within one second of atomic time and each other. Uploaded GRA12111.205 as patch file. 04/19/2012 06:18 darren@b 04:BadExcFreq: Alarm will be investigated during the next site visit. 04/16/2012 15:17 Rclark@b 02:InputSyncDetect,02:InputSyncLost: Caused by PSMFC personnel during reader replacement. 04/16/2012 10:13 Roger Performed site GMC on 4/16/2012. Transceivers 01 and 02 were replaced with 2020 transceivers. The noise floor on these transceivers is at approximately 8% to 10%. All other transceivers were checked for tune and adjusted as needed. PC1 is 5 seconds behind atomic time. PC2 is 18 seconds behind atomic time. There are no problems to report. 04/16/2012 08:36 Troy Manually pushed the delinquent file. 04/16/2012 07:38 alan@bay 04:BadOscFreq: This will be investigated today during a site visit. 04/11/2012 06:08 Rclark@b 03:LowExcCurrent,03:TestTagFailure: Transceiver was retuned on 4/10/2012. 04/10/2012 09:35 Alan A GMC was performed 4-10-2012. All transceivers were checked and tuned as necessary. Both PCs are four seconds behind atomic time. Outstanding files on PC2 were archived. No problems found. 04/06/2012 06:43 alan@bay 01:ReaderReset,02:InputSyncDetect,02:ReaderReset,03:ReaderReset,04:InputSy ncDetect,04:ReaderReset,05:ReaderReset,06:InputSyncDetect,06:ReaderReset,0 7:ReaderReset,08:InputSyncDetect,08:ReaderReset,12:ReaderReset,14:InputSyn cDetect,14:ReaderReset,16:InputSyncDetect,16:ReaderReset,18:InputSyncDetec t,18:ReaderReset,22:ReaderReset,24:InputSyncDetect,24:ReaderReset,26:Input SyncDetect,26:ReaderReset,28:InputSyncDetect,28:ReaderReset: Alarms caused by two short duration power outages. 04/05/2012 18:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/04/05 17:16:40 04/05/2012 18:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/04/05 17:12:19 04/05/2012 18:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2012/04/05 17:01:36 04/05/2012 18:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2012/04/05 16:12:47 04/03/2012 14:19 Rclark@b 03:TestTagFailure,12:ReaderReset,14:InputSyncDetect,14:InputSyncLost,18:In putSyncDetect,18:InputSyncLost: 03 was tuned on 4/3/2012. The errors on 12,14, and 18 are due to a random reader reset. 04/03/2012 09:31 Roger Performed site GMC on 4/3/2012. All transceivers were checked for tune and adjusted as needed. PC1 is 4 seconds behind atomic time. PC2 was 54 seconds behind atomic time and was adjusted to within 1 second of PC1. No problems to report. 04/03/2012 06:12 Rclark@b 03:TestTagFailure: This will be addressed during todays site visit. 04/02/2012 09:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/04/02 08:09:32 04/02/2012 09:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/04/02 08:08:18 04/02/2012 09:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/04/02 08:08:15 04/02/2012 09:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/04/02 08:06:54 04/02/2012 06:23 Rclark@b 03:TestTagFailure: The transceiver appears to have drifted out of tune. This will be addressed during the next site visit. 04/01/2012 08:33 Troy@bay 03:TestTagFailure: These will be addressed on the next site visit. 04/01/2012 08:27 Troy Stopped and started Multimon due to Day Light Savings time. The last file prior to the stop/start was the .103 file. 04/01/2012 06:16 Nicole Updated MultiMon database and map files to GRA12090.DB and GRA12090.MAP, respectively. These files contain instructions and tag codes for AC-11 (M. Biggs, Lemhi adult Chinook). PC2 clock is about 45 seconds behind PC1. 03/29/2012 07:04 scottl Best information available: The adult ladder was watered up around 08:00 on Friday 2-10-12. 03/29/2012 07:03 PTOC_Bot The trap was opened at 10:24 on Thursday 03/08/2012. 03/24/2012 06:41 alan@bay 02:LowExcCurrent,02:Overrun,03:LowExcCurrent: Alarms generated by PTAGIS Field Operations personnel during a site visit. 03/23/2012 10:42 Darren A site GMC was performed today (3-23-12). All transceivers were checked and adjusted for tuning, noise, and detectability. The buffers were cleared on all transceivers for this upcoming season. No problems were discovered during this GMC. 03/19/2012 12:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/03/19 11:21:20 03/19/2012 12:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/03/19 11:21:18 03/19/2012 12:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/03/19 11:21:18 03/19/2012 12:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/03/19 11:19:47 03/19/2012 12:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/03/19 11:19:35 03/19/2012 12:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'OFF' to 'ON' at 2012/03/19 11:19:27 03/19/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/03/19 11:19:26 03/19/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/03/19 11:19:24 03/19/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/03/19 11:19:15 03/19/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/03/19 11:16:44 03/19/2012 12:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/03/19 11:16:32 03/19/2012 12:01 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/03/19 11:16:17 03/19/2012 12:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/03/19 11:15:33 03/12/2012 15:00 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2012/03/12 13:28:10 03/12/2012 15:00 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/03/12 13:27:44 03/12/2012 11:45 Nicole Performed annual MultiMon reset. PC2 clock was 31 seconds behind atomic time. Both PC clocks were reset to be within one second of atomic time and each other. 03/09/2012 07:24 alan@bay 06:InputSyncDetect,06:ReaderReset: These alarms are the result of a random reader reset. 03/08/2012 12:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'OFF' to 'ON' at 2012/03/08 10:40:28 03/08/2012 12:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/03/08 10:40:28 03/08/2012 12:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/03/08 10:39:14 03/08/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/03/08 10:38:53 03/08/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/03/08 10:36:41 03/08/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'ON' to 'OFF' at 2012/03/08 10:28:45 03/08/2012 12:01 DGE_Robo B_Sample_100% (B_S100) changed from 'OFF' to 'ON' at 2012/03/08 10:28:42 03/08/2012 12:01 DGE_Robo A_Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2012/03/08 10:28:40 03/08/2012 12:01 DGE_Robo A_Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2012/03/08 10:28:38 03/08/2012 12:01 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2012/03/08 10:28:27 03/08/2012 12:01 DGE_Robo B_Sample_Bypass (B_SBypass) changed from 'ON' to 'OFF' at 2012/03/08 10:28:26 03/08/2012 12:01 DGE_Robo A_Sample_Bypass (A_SBypass) changed from 'ON' to 'OFF' at 2012/03/08 10:28:25 03/08/2012 12:01 DGE_Robo TrapGate (Trap) changed from 'CLOSED' to 'OPEN' at 2012/03/08 10:24:03 03/07/2012 09:53 Alan Files GRA12059.902 & 903 (from PC2) were tailored to fit the gap created during platform maintenance on 2-28-2012. Timestamp inconsistencies are due to the fact that PC2 had drifted 00:03:01 behind PC1 (which was ~00:06:00 ahead of atomic time), and that the clocks were set to atomic time when the platform was returned to service. The patch data contained in these files completely covers the gap created while PC1 was out of data collection. 03/01/2012 09:14 Nicole Updated MultiMon database and map files to GRA-GEN.DB and GRA-GEN.MAP. PC2 is 5 seconds behind PC1 and atomic time. GRA12061.206 uploaded as patch file. All other files on PC2 were archived. 02/28/2012 08:38 Alan PC1 was not able to be accessed by PCA. Site personnel cycled power at ~7:30 2-28-2012. The resultant gap in data will be patched from PC2. 02/11/2012 11:02 alan@bay 03:TestTagFailure: This alarm occurred prior to what appears to be the ladder watering up. We are awaiting confirmation of the water up and will post that information when it becomes available. 01/29/2012 08:53 rclark@b 03:TestTagFailure: Noted. 01/25/2012 07:26 Rclark@b 03:TestTagFailure: Noted. 01/09/2012 08:51 alan@bay 03:TestTagFailure: This will be addressed during the next site visit. 01/05/2012 07:37 darren@b 03:TestTagFailure: Site down clearing TASS. 01/04/2012 08:04 darren@b 01:LowExcCurrent,03:TestTagFailure: PSMFC was informed by site biologist Mike Halter that the ladder began the de-watering process yesterday and will be completed by EOB today. 01/01/2012 00:00 PTOC_Bot Annual log file initiation for GRA #### End of Event Log for GRA ###