EVENT LOG FOR SITE HLM The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/28/2012 16:15 Davids Operations Normal Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 12/28/2012 15:56 Davids Current operations normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 12/19/2012 16:22 Davids HLM is back online as of 12/18/2012 @ 17:02:50. Operations seem normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 12/10/2012 14:33 Davids Power was lost to the array from 10/30/12 @ 07:58:27 to 11/6/12 @ 13:38:42 from a fuel outage. Power was lost again from 12/6/12 @ 17:43:05 to the present due to a fuel outage. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 10/18/2012 16:14 Davids The TEG is operating well. A small pulse of tagged juveniles were detected moving past the array during the last few days, most likely due to the first rain in recent months. For unknown reasons, temperature data became invalid on 10/08/2012 at 05:50:00 and should be considered false until further notice. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 08/31/2012 11:30 Davids HLM is back online. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 03/29/2012 13:44 Davids TEG output voltages continue to fluctuate to values as low as 5 volts therefore, the transceiver was shut down on 03-26-2012 at 17:51:39 and will remain shut down until further notice. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 03/22/2012 12:05 Davids The site was down from 02/28/2012 at 06:48:45 to 03/19/ 2012 at 17:40:35 due to a failed shut-off valve in the thermoelectric generator. The shut- off valve was replaced along with the thermocouple, spark electrode, and spark igniter battery. The temperature probe was also reinstalled on 03/21/12. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 03/06/2012 12:27 Davids TEG operation began providing low output voltage on 2/27/12 at 09:10:00. The exact source of the problem is still unknown. The transceiver has not been operational since 2/28/12 at 06:48:45. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 02/29/2012 15:27 Davids Operations normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 02/16/2012 16:39 Davids Operations normal. The site is approximately 90% frozen and has not detected a tag for quite some time. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 02/10/2012 09:18 Davids Operations normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 01/30/2012 10:09 Davids Operations normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 01/23/2012 10:40 Davids Operations normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 01/10/2012 15:40 Davids Operations normal. Nick Davids Senior Fisheries Technician IDFG/PSMFC 3316 16th Street Lewiston, Idaho 83501 208-799-5010 nick.davids@idfg.idaho.gov 01/01/2012 00:00 PTOC_Bot Annual log file initiation for HLM #### End of Event Log for HLM ###