EVENT LOG FOR SITE JDJ Most recent activity to be listed first. First line of each entry lists date, time and who is reporting. Subsequent lines of each entry aligned under Time column. Do not use tabs, only spaces. Date Time Who What ---------- ----- -------- ----------------------------------------------- 12/20/2005 14:33 Alan_Bro With the help of on site personnel, it has been determined that we have lost our internet connection at JDJ. This facility is currently de-watered. PTAGIS Field Operations will remedy the situation when time allows. 12/19/2005 08:44 Alan_Bro These sites have stopped sending files and are unavailable via PCA. Messages have been left for site personnel, and we are working to restore proper operation. These sites are currently de-watered. 12/02/2005 17:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/12/01 12:52:35 12/02/2005 17:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/12/01 12:52:29 12/01/2005 02:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/12/01 01:02:30 12/01/2005 02:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/12/01 01:02:24 11/30/2005 08:46 Alan_Bro JDJ05332.106 is MIA. Remote access is currently unavailable. This is largely inconsequential as the facility is out of production. PTAGIS Field Operations will send the file at the next available opportunity. 11/18/2005 14:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/11/18 13:50:13 11/18/2005 14:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/11/18 13:50:07 11/18/2005 14:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/11/18 12:50:20 11/18/2005 14:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/11/18 12:50:14 11/04/2005 11:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/11/04 10:44:09 11/04/2005 11:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/11/04 10:44:03 11/02/2005 08:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/11/02 07:21:26 11/02/2005 08:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/11/02 07:21:20 10/31/2005 08:51 Scott_Li Manually PCA'd into each of the multimon sites and stopped and started the MM application due to the daylight savings time Phenom. 10/12/2005 18:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/10/12 16:00:54 10/12/2005 18:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/10/12 16:00:48 10/11/2005 00:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/10/10 21:01:53 10/11/2005 00:58 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/10/10 21:01:47 09/28/2005 16:29 Dave I procedurally closed JDJ05271.104, which was truncated due to a power outage. I also updated etc/sites to disable site checking, as the JDA sampling and bypass facility is dewatered until next Spring. 09/28/2005 15:57 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/09/28 12:24:21 09/28/2005 15:57 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/09/28 12:24:21 09/28/2005 15:57 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/28 12:24:21 09/28/2005 15:57 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/09/28 12:24:21 09/28/2005 13:40 Alan_Bro Manually pushed JDJ05271.104 to PTAGIS via PCA. 09/28/2005 13:39 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/09/28 11:23:16 09/28/2005 13:39 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/09/28 11:23:16 09/28/2005 13:39 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/09/28 11:23:14 09/28/2005 13:39 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/28 11:23:14 09/23/2005 08:22 scottl@r 83:InputSyncDetect,83:ReaderReset: Known problem, not of concerna this time. 09/20/2005 11:00 Alan_Bro Manually pushed JDJ05263.103 to PTAGIS via PCA. 09/20/2005 08:03 scottl@r C2:InputSyncDetect,C2:ReaderReset: Ongoing periodic problem, not of concern at this time. 09/15/2005 19:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 16:11:33 09/15/2005 19:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 16:11:27 09/15/2005 11:59 Dave Greg Kovalchuk informed me that the John Day Dam Smolt Monitoring Facility was dewatered and shut down for the season at 7:00AM (PDT) this morning, Sept. 15. I've updated the ptagis3.obs_dates table to reflect this change in activity. 09/15/2005 10:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:13:54 09/15/2005 10:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:13:29 09/15/2005 10:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:13:27 09/15/2005 10:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:13:02 09/15/2005 10:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:12:59 09/15/2005 10:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:12:44 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:12:29 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:04:16 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:04:16 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:04:16 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:04:16 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:04:16 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:04:15 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:04:15 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:04:15 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:04:08 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:04:08 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:04:07 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:04:06 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:03:59 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:03:46 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:03:43 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:03:41 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:03:41 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:03:22 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:03:18 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:03:17 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/09/15 06:03:16 09/15/2005 10:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/09/15 06:03:01 09/15/2005 07:08 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/09/15 05:53:11 09/15/2005 07:08 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/09/15 05:53:09 08/23/2005 11:24 Alan_Bro A GMC was performed 8/23/2005. All transceivers were tuned. 20 sticks were thrown on the SbyC Separator gate, all sticks were properly diverted to the SbyC gate which were then properly diverted to the West tank, results for the monitors following: A1 20/20 A2 20/20 A3 19/20 A4 19/20 C1 20/20 C2 20/20 C3 20/20 C4 20/20 F1 19/20 F2 20/20 The air pressure on the SbyC Separator gate is 100psi. The air pressure on the SbyC gate is 80psi. Multimon is running in full screen mode on both PCs. No problems found. 08/21/2005 13:07 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/08/21 09:53:17 08/21/2005 11:51 dlwarf@r A3:InputSyncDetect,A3:ReaderReset: Common reader reset. 08/21/2005 10:07 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/08/21 07:23:16 08/20/2005 13:08 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/08/20 11:53:20 08/17/2005 17:17 Dave I resubmitted JDJ05129.101 and JDJ05129.104 in order to capture the detection data for a live fish carrying a tag previously identified as a test tag. 08/16/2005 10:07 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/08/16 06:00:18 08/15/2005 16:15 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/08/15 12:23:35 08/08/2005 08:21 troy@ruf A3:Overrun: No readily apparent cause for this overrun. PSMFC will monitor for future occurrences 08/05/2005 08:55 darren@r 91:ReaderReset,92:InputSyncDetect,92:InputSyncLost,94:InputSyncDetect,94:I nputSyncLost: Alarms were generated by a random reader reset. 08/04/2005 15:13 Alan_Bro A GMC was performed 8/4/2005. All transceivers were tuned. 15 sticks were thrown on the SbyC Separator gate, all sticks were properly diverted to the SbyC gate which were then properly diverted to the West tank, results for the monitors following: A1 15/15 A2 15/15 A3 15/15 A4 15/15 C1 15/15 C2 15/15 C3 15/15 C4 15/15 F1 15/15 F2 15/15 The air pressure on the SbyC Separator gate is 100psi. The air pressure on the SbyC gate is 80psi. Multimon is running in full screen mode on both PCs. No problems found. 07/20/2005 13:05 Alan_Bro A GMC was performed 7/20/2005. All transceivers were tuned. 20 sticks were thrown on the SbyC Separator gate, all sticks were properly diverted to the SbyC gate which were then properly diverted to the West tank. Additionally 20 sticks were thrown into the East tank monitor and 20 thrown into the Sample Room monitor, results for the monitors following: A1 20/20 A2 20/20 A3 20/20 A4 19/20 C1 20/20 C2 20/20 C3 20/20 C4 20/20 F1 20/20 F2 20/20 E1 20/20 E2 20/20 51 20/20 52 20/20 53 20/20 54 20/20 The air pressure on the SbyC Separator gate is 98psi. The air pressure on the SbyC gate is 91psi. Multimon is running in full screen mode on both PCs. No problems found. 07/18/2005 16:13 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/07/18 14:49:12 07/18/2005 16:13 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/07/18 14:49:11 07/18/2005 13:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/07/18 10:02:59 07/18/2005 13:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/07/18 10:02:58 07/18/2005 13:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/07/18 10:02:58 07/18/2005 13:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/07/18 10:02:57 07/18/2005 13:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/07/18 10:02:57 07/18/2005 13:08 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/07/18 10:02:55 07/17/2005 10:14 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/07/17 08:27:34 07/17/2005 10:14 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/07/17 08:27:34 07/15/2005 10:11 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/07/15 08:30:51 07/15/2005 10:11 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/07/15 07:54:52 07/14/2005 10:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/07/14 08:27:27 07/14/2005 10:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/07/14 07:24:51 07/12/2005 13:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/07/12 09:24:55 07/12/2005 10:11 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/07/12 08:06:00 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/07/09 06:15:02 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/07/09 06:14:38 07/09/2005 10:11 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/07/09 06:14:36 07/09/2005 10:11 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/07/09 06:14:03 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/07/09 06:14:02 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/07/09 06:14:01 07/09/2005 10:11 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/07/09 06:14:01 07/09/2005 10:11 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/07/09 06:06:44 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/07/09 06:05:06 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/07/09 06:05:03 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/07/09 06:05:02 07/09/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/07/09 06:04:42 07/08/2005 10:11 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/07/08 07:55:05 07/08/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/07/08 07:55:03 07/08/2005 10:11 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/07/08 06:55:06 07/08/2005 10:11 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/07/08 06:55:05 07/06/2005 13:38 Scott_Li SMP personnel called to report that a power surge at the SMP facility occurred at ~ 13:25 today. PCA'd into primary computer and all indications are that no damage to the PIT-tag equipment occurred. 07/06/2005 12:40 Darren A site GMC was performed today (7-6-05). All transceivers were checked for tuning and noise. 20 diversion test sticks were passed through the "A" separator monitor with 100% diversion and detection. No problems were found. 07/05/2005 08:15 troy@ruf SLC500:CommsFailure: The pittag was diverted correctly dispite this alarm. This a known problem, the exact cause is not yet known. 07/02/2005 10:55 alan@ruf SLC500:CommsFailure: PSMFC is working on a solution for this problem. The PIT Tag in question was diverted properly. 06/29/2005 13:18 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/29 09:55:27 06/29/2005 13:18 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/29 09:55:27 06/29/2005 10:16 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/29 07:55:27 06/29/2005 10:16 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/29 07:08:17 06/27/2005 10:17 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/27 07:55:31 06/27/2005 10:17 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/27 07:55:31 06/27/2005 07:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/27 05:55:32 06/27/2005 07:09 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/27 05:55:32 06/24/2005 10:14 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/24 08:15:39 06/24/2005 10:14 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/24 08:15:39 06/24/2005 10:14 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/24 07:55:39 06/24/2005 10:14 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/24 07:55:39 06/21/2005 16:09 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/21 12:25:46 06/21/2005 16:09 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/21 12:25:33 06/19/2005 11:28 dlwarf@r E2:InputSyncDetect,E2:ReaderReset: Reader reset noted. 06/17/2005 10:08 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/17 07:55:57 06/17/2005 10:08 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/17 07:55:56 06/17/2005 10:07 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/17 06:55:57 06/17/2005 10:07 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/17 06:55:56 06/16/2005 10:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/16 07:05:59 06/15/2005 13:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/15 11:56:01 06/15/2005 10:08 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/15 07:56:00 06/15/2005 10:08 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/15 07:56:00 06/15/2005 08:04 darren@r 91:ReaderReset,92:InputSyncDetect,92:ReaderReset,93:InputSyncDetect,94:Inp utSyncDetect,94:InputSyncLost,A3:InputSyncDetect,A3:ReaderReset,A4:InputSy ncDetect,A4:ReaderReset: Alarms were generated by PSMFC personnel troubleshooting a transceiver problem. The problem was discovered as a tripped breaker. The breaker was reset and the cause of the trip was discovered to be a pressure washer that was plugged into a maintenance outlet below the enclosure that houses transceivers 91 and 92. 06/15/2005 07:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/15 05:56:02 06/15/2005 07:09 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/15 05:56:01 06/14/2005 14:55 Darren_C PSMFC personnel discovered that there was a problem with transceiver's A3, A4, 91, and 92. They had not fired a timer tag and could not be communicated with via PC anywhere. After checking "raw" files it looked like the last time they were heard from was at 09:43:41 yesterday. I arrived to find that the breaker for those transceivers had been tripped. The breaker was reset and all transceivers were found to be in working condition. I could not find any reason for the tripped breaker. Site personnel said that a pressure washer had been plugged into the maintenance outlet just below the enclosure for transceivers 91 and 92 and that it had tripped the breaker. I checked the panel and it appears that both receptacles are on the same circuit. Darren R. Chase PSMFC Systems Engineer (509) 735-2773 ext.3 06/14/2005 13:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/14 11:56:02 06/14/2005 13:09 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/14 11:56:02 06/14/2005 10:10 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/14 07:46:03 06/14/2005 10:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/14 07:46:03 06/14/2005 09:06 scottl@r 93:InputSyncLost,94:InputSyncDetect,94:InputSyncLost: Personell will be on-site today.. 06/10/2005 08:32 scottl@r SLC500:CommsFailure: Noted 06/08/2005 11:22 Troy A site GMC was performed 06/08/05. All transceivers were checked for tune and no problems were found. The 3 Way gate is at 100 PSI and the 2 Way gate is at 80 PSI. 30 sticks were thrown and the results are as follows: A1 30 of 30 C1 30 of 30 F1 30 of 30 A2 30 of 30 C2 30 of 30 F2 30 of 30 A3 30 of 30 C3 30 of 30 A4 30 of 30 C4 30 of 30 06/04/2005 13:06 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/04 09:16:30 06/04/2005 13:06 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/04 09:16:29 06/04/2005 10:07 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/04 08:56:29 06/03/2005 16:12 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/03 12:56:30 06/03/2005 10:43 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/03 07:26:31 06/02/2005 16:10 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/02 12:56:32 06/02/2005 10:07 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/02 07:26:34 06/02/2005 10:07 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/02 07:26:33 06/01/2005 16:14 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/06/01 12:56:56 06/01/2005 16:14 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/06/01 12:56:37 06/01/2005 12:26 troy A site GMC was performed 06/01/05. All transceivers were checked for tune and no problems were found. The site is in 100% sample with DDS ON. I was able to check this function and did so with 30 sticks. All sticks were diverted correctly. I will mention to Greg that it would be a good idea to replace the shocks on the 3 way next winter as it bangs harder going from Left to Right than it does to TDC to the right or left and I presume it has been a few years since these shocks have been replaced. The air pressure at the 3 way is 100 PSI and 80 PSI at the 2 way. The stick test results are below A1 29 of 30 C1 30 of 30 A2 30 of 30 C2 20 of 20 A3 30 of 30 C3 30 of 30 A4 30 of 30 C4 30 of 30 F1 30 of 30 F2 30 of 30 The phone lines were moved to fit the computer(s) configuration. PC1 is now on the DSL POTS line, dialing a local number (this was verified and a connection was made) PC2, the Ulitity and the Phone are on the COE PBX line. The configuration was verified and tested. PC2 would connect but the Ulility will not. 06/01/2005 10:07 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/06/01 07:26:38 06/01/2005 10:07 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/06/01 07:26:37 05/31/2005 16:13 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/31 12:56:36 05/31/2005 16:13 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/31 12:56:36 05/31/2005 10:26 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/31 06:56:38 05/31/2005 10:26 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/31 06:56:38 05/30/2005 16:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/30 12:56:41 05/30/2005 16:10 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/30 12:56:40 05/30/2005 10:17 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/30 07:46:41 05/30/2005 10:17 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/30 07:46:41 05/30/2005 09:20 darren@r SLC500:CommsFailure: Although there was an alarm the PITtag did indeed travel on it's intended path. PSMFC is investigating the "SLC Comms failure", it may be caused by an acknowledgment that is not received by the PLC. PSMFC will post the findings when available. 05/29/2005 16:18 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/29 13:06:42 05/29/2005 16:18 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/29 13:06:41 05/29/2005 10:24 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/29 07:56:42 05/29/2005 10:24 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/29 07:56:42 05/28/2005 13:37 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/28 10:56:45 05/28/2005 13:37 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/28 10:56:45 05/28/2005 10:28 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/28 08:36:45 05/28/2005 10:28 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/28 08:36:45 05/27/2005 16:31 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/05/27 12:36:48 05/27/2005 16:31 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/05/27 12:35:48 05/27/2005 16:31 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/27 12:32:55 05/27/2005 16:31 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/27 12:32:19 05/27/2005 13:29 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/27 09:56:47 05/27/2005 13:29 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/27 09:56:12 05/27/2005 13:29 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/27 09:36:49 05/27/2005 13:29 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/27 09:36:48 05/27/2005 08:45 alan@ruf SLC500:CommsFailure: There was no direct cause for this alarm. The PIT Tag in this particular situation was diverted properly. 05/26/2005 14:51 Dave I updated the JDA map file to JDJ05146.MAP. This version de-activates diversion of the USGS McCall Hatchery group (USGSMH, AC-71). The new map was installed at approximately 2:30PM, PDT. Any AC-71 tags arriving after this time will be detected and audited, but not diverted to the SbyC tank. The PC clocks are within 7 seconds of each other and 14 seconds of atomic time. 05/26/2005 13:34 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/26 09:56:50 05/26/2005 13:34 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/26 09:56:50 05/26/2005 10:40 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/26 07:26:51 05/26/2005 10:40 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/26 07:26:51 05/26/2005 08:14 scottl@r 61:BadOscFreq,61:InputSyncLost,61:LowExcCurrent,62:InputSyncDetect,SLC500: CommsFailure: Errors are not a real concern at this time. 61 may need replaced at some point. 05/25/2005 15:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/25 09:36:51 05/25/2005 15:02 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/25 09:36:51 05/25/2005 13:40 Troy A site GMC was performed 05/25/05. All transceivers were checked for tune and no problems were found. 30 sticks were thrown with the blessing of USGS which was on site. All sticks were read on all the appropriate coils and all sticks were diverted correctly. USGS was informed that there may be some fish in their tank that do not belong to their study as a result of the stick test. Jessica agreed to the test and will check each fish in the tank to determine if they belong to her study or not. The 2 way is at 80 PSI and the 3 way is at 100 PSI. 05/25/2005 12:03 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/25 08:27:36 05/25/2005 12:03 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/25 08:27:36 05/25/2005 09:27 Alan_Bro File JDJ05144.106 was manually submitted via PCA to fill the 23 minute gap. The archive path was inadvertently set incorrectly on 5/23/2005. The archive path was changed to c:\multimon\archive and the incorrectly archived files were copied to that folder. 05/25/2005 08:17 troy@ruf SLC500:CommsFailure: PSMFC personnel will be on site today to verify that all cabling is tight and look for any physical causes for this alarm. 05/24/2005 14:49 Scott_Li The DSL data services are back online and tested good. The dial up connection to Gorgnet also was test and functioning as the backup service. Per Sprint, the problem with the DSL service was in the central office and also found the DMS was damaged caused by deterioration. This is the exact wording per sprint. Sent tardy files to ptagis and set the clock on pc1 to within 2 seconds of atomic time and PC1 and 2 are within 3 seconds of each other 05/24/2005 14:25 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/24 10:16:27 05/24/2005 14:25 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/24 10:16:27 05/24/2005 14:24 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/24 08:56:48 05/24/2005 14:24 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/24 07:35:05 05/24/2005 09:53 Don_Warf The current problems with getting data from the site are due to the COE removing us from their network. Because we were only given 3 weeks advance notice from the COE we are still trying to find a stable connection. If the current DSL connection is proven to be unreliable, we will look into other options. These include dial-up and satellite. 05/24/2005 09:33 Scott_Li This PIT-event is an appendage to the previous.. The DSL data services for the PIT-tag interrogation platform is currently under repair and is still being refined to achieve stability. Sprint is working on the problem today 5/24/05. In the mean time, PTOC O@M will continue to monitor the situation to ensure data services are provided. In event that the DSL service becomes problematic and consistently unreliable, dialup to Gorgenet ISP will be the fall back plan. We are currently working to resolve the PTTP transaction problem that occurs during a dial-up session described in the previous PIT-event. 05/24/2005 09:11 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/23 09:05:37 05/24/2005 09:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/23 08:14:33 05/24/2005 08:47 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/21 08:31:31 05/24/2005 08:46 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/21 08:01:23 05/24/2005 08:43 Scott_Li Site visit confirmed that the DSL link is down, no light on the modem. Cycled power on the modem 3 times , still no light. Placed trouble call with Sprint, they should respond by 1:00 pm today and call with status. Tried to configure the data collection platform to utilize the dial up service through Gorgenet but ran into problems with the FTP client when transferring files. This exact same issue was experienced by another tech when configuring the RCX platform. Below is a snippet from the PTTP log file at JDJ-PC1. Dial-up 05/23/05 12:55:40 INFO Port opened:OK Dial-up 05/23/05 12:55:40 INFO Connect device:OK Dial-up 05/23/05 12:56:05 INFO Device connected:OK Dial-up 05/23/05 12:56:05 INFO All devices connected:OK Dial-up 05/23/05 12:56:05 INFO Start authentication:OK Dial-up 05/23/05 12:56:05 INFO Authenticate:OK Dial-up 05/23/05 12:56:11 INFO Authenticated:OK Dial-up 05/23/05 12:57:12 INFO Logon network:OK Dial-up 05/23/05 12:57:12 INFO Connected:OK FTP 05/23/05 12:57:14 INFO Server: Connecting to FTP server. FTP 05/23/05 12:57:14 INFO Server: Connected. FTP 05/23/05 12:57:17 INFO Server: 220 ftp.ptagis.org FTP server ready. FTP 05/23/05 12:57:17 INFO Client: USER ptoc FTP 05/23/05 12:57:17 INFO Server: 331 Password required for ptoc. FTP 05/23/05 12:57:17 INFO Client: PWD authenticated FTP 05/23/05 12:57:17 INFO Server: 230 User ptoc logged in. Access restrictions apply. FTP 05/23/05 12:57:17 INFO Client: CWD STAGE FTP 05/23/05 12:57:18 INFO Server: 250 CWD command successful. Sys 05/23/05 12:57:18 INFO Submitting package to remote server... FTP 05/23/05 12:57:18 INFO Client: TYPE I FTP 05/23/05 12:57:18 INFO Server: 200 Type set to I. FTP 05/23/05 12:57:18 INFO Client: PORT 209,216,178,191,7,110 FTP 05/23/05 12:57:18 INFO Server: 200 PORT command successful. FTP 05/23/05 12:57:18 INFO Client: STOR TX3EE826DC-CB89-11D9-B462-00E029845CC2.zip FTP 05/23/05 12:57:19 INFO Server: 150 Opening BINARY mode data connection for TX3EE826DC-CB89-11D9-B462-00E029845CC2.zip. Sys 05/23/05 12:57:38 ERROR Error transmitting PTTP package:Operation interrupted. FTP 05/23/05 12:57:38 INFO Client: QUIT FTP 05/23/05 12:57:58 INFO Server: Disconnected. Dial-up 05/23/05 12:57:59 INFO An operation is pending.:Disconnected Dial-up 05/23/05 12:58:00 INFO Disconnected:OK Sys 05/23/05 12:58:00 ERROR File upload process failed. 05/22/2005 10:25 Alan_Bro A call to site personnel verified that data is being collected as of 09:20 (10:20 PDT). 05/21/2005 09:13 Alan_Bro A call to site personnel verified that data is being collected as of 08:12 (9:12 PDT). 05/21/2005 08:34 alan@ruf SLC500:CommsFailure: There was no direct cause for this alarm. The PIT Tag in this particular situation was diverted properly. 05/20/2005 17:36 Darren_C The site has not loaded since 00:00 this morning (5-20-05). I dug into the situation at about 15:30 and found that there was no DSL connection. I tried to switch the upload process over to a dial-up connection but I all I received were error messages when the files were submitted and then disconnection. I switched the upload process over to DSL after talking with Don and it was decided that we would monitor the data collection process over the weekend and then travel down on Monday. I spoke to Sprint DSL tech support but they are not reporting any outages in the area. If the DSL connection does come back the upload process should submit all the files. Darren R. Chase PSMFC Systems Engineer (509) 735-2773 ext.3 05/20/2005 08:25 Troy A site GMC was performed 05/19/05. All transceivers were checked for tune and no problems were found. Both gates were test fired and seem to operating well. Both are at 100 PSI. No sticks were thrown due to high fish volumes. The phone that was used for PC2, the Utility machine and the physical phone was taken off the COE PBA system on hooked up to the analog part of our new DSL line. The new number for the pittag room, and PC2 is 1 (541)739-8245. 05/19/2005 08:10 troy@ruf SLC500:CommsFailure: Noted. 05/16/2005 08:05 darren@r SLC500:CommsFailure: There was no direct cause for this alarm. The PITtag in this particular situation was diverted properly. 05/11/2005 14:44 Alan_Bro A GMC was performed 5/11/2005. All transceivers were tuned. The air pressure is currently 98psi on the 3-way and 90psi on the 2-way. The gates were tested and found in good working order. No sticks were thrown. A lot of fish are moving across the separator and site personel expressed an interest not to have the bycatch in the SbyC tanks. No problems found. 05/11/2005 13:03 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/11 09:57:36 05/11/2005 13:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/11 09:07:13 05/11/2005 10:03 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/11 07:08:17 05/11/2005 10:03 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/11 07:08:03 05/08/2005 07:03 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/08 05:57:12 05/07/2005 16:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/07 12:29:01 05/07/2005 16:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/07 12:28:51 05/07/2005 16:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/07 12:27:19 05/07/2005 13:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/07 10:57:13 05/07/2005 13:02 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/07 10:57:11 05/07/2005 13:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/07 09:57:13 05/07/2005 13:02 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/07 09:57:12 05/07/2005 10:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/07 06:59:12 05/06/2005 16:02 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/06 12:27:14 05/06/2005 10:10 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/06 08:57:18 05/06/2005 10:10 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/06 08:57:15 05/06/2005 10:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/06 06:58:12 05/05/2005 18:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/05 12:27:22 05/05/2005 18:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/05 12:27:20 05/05/2005 18:02 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/05 12:27:18 05/05/2005 12:57 Alan_Bro A GMC was performed 5/5/2005. All transceivers were tuned. PC1 was taken out of data collection to re-establish PCA network connectivity. File JDJ05125.205 was submitted manually from PC2 to fill the gap while PC1 was down. PCA network connectivity was sucessfully tested on both PCs. PC1's clock is 00:00:10 ahead of atomic time. PC2's clock is 00:00:06 ahead of atomic time. The air pressure is currently 100psi on the 3-way and 90psi on the 2-way. 20 sticks were thrown on SbyC separator gate and 10 sticks were thrown into the flume for the SbyC east tank, all sticks diverted properly. Test results following: A1 20/20 A2 20/20 A3 20/20 A4 17/20 C1 20/20 C2 20/20 C3 20/20 C4 20/20 E1 20/20 E2 20/20 F1 20/20 F2 20/20 No Problems found. 05/05/2005 10:20 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/05 08:27:15 05/05/2005 10:20 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/05 08:27:13 05/05/2005 10:20 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/05/05 06:02:54 05/04/2005 14:55 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/05/04 12:26:44 05/04/2005 10:24 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/05/04 08:56:48 05/04/2005 10:24 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/05/04 08:56:48 05/02/2005 10:47 PTOC_Bot I've programmatically 'CLOSED' JDJ05115.105. 04/29/2005 16:05 Scott_Li The DSL data services for the interrogation platforms is up and functional.. Data is being transmitted to PTAGIS via this service as of ~ 14:30 hrs 4/28/05. I/P addresses will be posted next week.. At this time, remote access via I/P to the interrogation computers is not available. A configuration change to PCA is necessary and cannot be done remotely even over a dial up service. The configuration change will be done next week, more than likely on 5/4/05. In mean time, dial-up services are still available for system administration. 04/29/2005 08:44 Alan_Bro Manually pushed JDJ05118.108 to PTAGIS via PCA. 04/26/2005 08:55 Troy A GMC was performed 04/25/05. All transceivers were checked for tune and no problems were found. 04/20/2005 13:57 Dave Troy asked me to relay that he manually sent files JDJ05110.103-104, and reset the clock on JDJ-PC2 to match that of JDJ-PC1. 04/20/2005 13:25 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/04/20 11:24:17 04/20/2005 13:25 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/04/20 11:21:53 04/19/2005 10:11 Alan_Bro Manually pushed JDJ05108.106, JDJ05108.107, JDJ05108.108, JDJ05108.109, JDJ05109.101, JDJ05109.102 and JDJ05109.103 to PTAGIS via the LAN. PC1 was configured to use the LAN for automated uploads. The dialup connection is having troubles. PTAGIS Field Operations is working on a more robust connection. More information forthcoming as it becomes available. 04/19/2005 08:04 Alan_Bro Ptagis Field Operations is looking into the whereabouts of the tardy files. 04/18/2005 15:24 Scott_Li DSL data services to the JFF at this time will not be possable. This is due to an 18K distance limintation from the central switch to the JDJ JFF. Sprint was successful in getting the DSL link to the powerhouse phone room and achieving speeds of 800 kbps down and 704 kbps up. Ptagis field ops will look into utilizing spare fiber optic cables that exist in the room adjacent to the PIT tag room to bring the DSL service into the PIT room. this will require some Fiber to Ethernet conversion but appears to completely possable provided the COE agrees to allocate 2 spare fibers from the bundle. The service order with Sprint was kept open with the status of "Customer will Advise". This will give us some time to evaluate the situation with hopes that DSL will still be possable. FYI. The interrogation computers were reconfigured to utilize dial-up networking through the Gorgenet ISP for data transfers to PTAGIS. PCA remote users will be required to come in direct dial-up to PC1 or 2. PC1 will answer the calls in 3 rings and PC2 will pickup on 1 ring. Both interrogation computers were tested for successful comms through the ISP to PTAGIS and the PCA configuration for remote access was also successful. The last issue is that PC1 and 2 will need the Win98 patch files installed in order to avoid the "Ghost button" phenom that appears in the task bar after ever dial-up session. This is a known problem and does not appear to cause harm but more of a nuisance if anything. Irregardless, this patch needs to be inplimented. Scott does not have the files in hand at this time to make the patch. 04/15/2005 11:19 Dave Updated database to JDJ05105.DB. This version contains the 200 new SGL test tags, equally apportioned between AC-254 and AC-255. Updated JDJ-GEN.DB on both machines, and refreshed WATCH.TAG on PC2. Updated the FTP client on both machines to refer to the actual, rather than linked, Site_COnfiguration location on the PTAGIS FTP server. PC clocks are within 6 seconds of each other and 21 seconds of atomic time. 04/15/2005 08:23 troy@ruf 61:BadOscFreq,61:InputSyncDetect,61:LowExcCurrent,61:ReaderReset,62:BadOsc Freq,62:InputSyncDetect,62:InputSyncLost,62:LowExcCurrent,62:ReaderReset: These alarms were caused by PSMFC personnel trouble shooting the noise spikes of 61. 04/14/2005 14:51 Troy A site GMC was performed 04/14/05. All transceivers were checked for tune.Transceiver 61 is experiencing interminted spikes in noise(up to 15-17). The sync in-out was swapped to see if it was a sync problem. This did not fix the problem. Found water in the monitor. I drilled a drain hole but I suspect water is under the coil. Some modifications to the upstream side of the monitor will have to be done to keep water out in the future. 30 sticks were thrown the results are as follows A1-A4 30 of 30 C1-C4 30 of 30 F1-F2 30 of 30 No other problems were found. 04/14/2005 10:53 Alan_Bro PTAGIS Field Operations personnel will be onsite today and will investigate. -----Original Message----- From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Thursday, April 14, 2005 10:15 AM To: sitemaint@psmfc.org Subject: Problems with remote data sites... The following problems with remote sites were detected; jdj: Last data submission was received on Thu Apr 14 6:02:30 PST 2005 Please check this out. 04/12/2005 09:51 Don_Warf On Monday 4/18 we will be leaving the COE network at JDJ and changing over to our own DSL account. 04/08/2005 10:34 alan@ruf 61:ReaderReset,62:InputSyncDetect,62:InputSyncLost: These alarms were generated by a random reader reset. PSMFC and Digital Angel are aware of the problem. 04/07/2005 14:15 Alan_Bro Upon arrival, the network connections had miraculously healed themselves. Multimon sessions on both PC1 and PC2 were terminated by a USACE scan of our computers on the LAN at approximately 11:32 PST (12:32 PDT). Both PCs were re-booted. File JDJ05097.104 was truncated. File JDJ05097.304 was created by modifying JDJ05097.104 so as to add a closing time stamp. Files JDJ05097.304 and JDJ05097.105 were manually submitted to PTAGIS. 04/07/2005 08:51 Alan_Bro Confirmed by site personnel, we are having network issues. I am going to the site to rectify the situation. -----Original Message----- From: pittag@psmfc.org [mailto:pittag@psmfc.org] Sent: Thursday, April 07, 2005 7:15 AM To: sitemaint@psmfc.org Subject: Problems with remote data sites... The following problems with remote sites were detected; jdj: Last data submission was received on Thu Apr 7 3:02:15 PST 2005 Please check this out. 04/06/2005 14:32 Troy A start of season GMC was performed 04/05/05. All transceivers were checked for tune and no problems were found. The 2 way and three way gates were checked for time. The Air pressures and gate times are as follows: 3 Way 100 psi 2 Way 85 psi 3 Way Delay Op 5 3 Way Time Open 135 2 Way Delay Op 9 2 Way Time Open 120 3 Way Delay Op divert during sample 10 3 Way Delay Op all during sample 5 3 Way Time Open all divert during sample 160 The air to the 2 way had been turned off. In consulting with site personnel it was decided to turn the air on for testing and to leave it on. 40 sticks were thrown on the following coils and the results are as below. DDS was checked on the 3 way with 1 AC_254 and 1 AC_255. It appears that the database is not setup to send AC_255's or AC_254's back to the river as both AC_255 and AC_254 were diverted to the 2 way SbyC gate. A1 42 of 42 A2 42 of 42 A3 42 of 42 A4 42 of 42 C1 82 of 82 C2 82 of 82 C3 82 of 82 C4 82 of 82 51 40 of 40 52 40 of 40 53 40 of 40 54 40 of 40 E1 40 of 40 E2 40 of 40 F1 42 of 42 F2 42 of 42 61 36 of 40 (orientation issue) 62 39 of 40 The transceiver firmware v5.0 upgrade was verified as well. 04/05/2005 18:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/04/05 13:09:38 04/05/2005 18:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/04/05 12:59:56 04/05/2005 13:12 Dave With Alan's assistance, I was able to pcA into both JDJ-PC1 and JDJ-PC2. I then assisted Alan in installing the first production SbyC configuration files, JDJ05091.MAP and JDJ05091.DB. The database contains 3000 tag codes for fish tagged for USGS at McCall hatchery (USGSMH, AC-71). These fish will be diverted to the West SbyC Tank. The PC clocks were reset to within 2 seconds of each other and atomic time. 04/04/2005 15:55 Scott_Li PCA'd into PC2 this morning and stopped then started Multimon. Was not able to access PC1. Call the site for support but was paying phone tag with the assistant Bio. PTAGIS personnel will be on-site tomorrow and will address the problem with PC1 04/04/2005 08:21 Scott_Li Called SMP office to request assistance in stopping and starting the Multimon application in order to resync the platform due to the DST change over. Left message with Greg K to call when available. Scott Livingston Field Systems Engineer Pacific States Marine Fisheries Commission 509.735.2773 x. 2 04/03/2005 11:16 Dave I pcA'd in and stopped, and then immediately restarted, MultiMon, to adjust the file creation times on PC2 only. I was unable to remotely connect to JDJ-PC1, although pcA initially displayed a blank connection window, which I finally manually terminated. Subsequent attempts to connect resulted in time-out messages. 04/01/2005 16:32 Dave Greg Kovalchuk let us know that the John Day Juvenile Monitoring Facility (JMF) became operational at 9:50AM today. 04/01/2005 12:03 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/04/01 09:25:43 04/01/2005 12:03 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/04/01 09:23:56 04/01/2005 12:03 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/04/01 09:23:01 04/01/2005 12:03 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/04/01 09:22:57 04/01/2005 12:03 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/04/01 09:22:46 04/01/2005 12:03 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/04/01 09:22:38 04/01/2005 09:02 Dave I updated etc/sites and modified the alert notification to include Portland as well as Kennewick PTAGIS staff. 04/01/2005 08:14 scottl@r 51:ReaderReset,52:InputSyncDetect,52:ReaderReset,53:InputSyncDetect,53:Rea derReset,54:InputSyncDetect,54:ReaderReset,61:ReaderReset,62:InputSyncDete ct,62:ReaderReset,81:ReaderReset,82:InputSyncDetect,82:ReaderReset,83:Inpu tSyncDetect,83:InputSyncLost,83:ReaderReset,84:InputSyncDetect,84:ReaderRe set,91:ReaderReset,92:InputSyncDetect,92:ReaderReset,93:InputSyncDetect,93 :ReaderReset,94:InputSyncDetect,94:ReaderReset,A1:ReaderReset,A2:InputSync Detect,A2:ReaderReset,A3:InputSyncDetect,A3:ReaderReset,A3:RocketPortNoEOT ,A4:InputSyncDetect,A4:ReaderReset,C1:ReaderReset,C2:InputSyncDetect,C2:Re aderReset,C3:InputSyncDetect,C3:ReaderReset,C4:InputSyncDetect,C4:ReaderRe set,E1:ReaderReset,E2:InputSyncDetect,E2:ReaderReset,F1:ReaderReset,F2:Inp utSyncDetect,F2:ReaderReset: Resets caused by brief power outages 04/01/2005 08:13 scottl@r 51:ReaderReset,52:InputSyncDetect,52:ReaderReset,53:InputSyncDetect,53:Rea derReset,54:InputSyncDetect,54:ReaderReset,61:ReaderReset,62:InputSyncDete ct,62:ReaderReset,81:ReaderReset,82:InputSyncDetect,82:ReaderReset,83:Inpu tSyncDetect,83:InputSyncLost,83:ReaderReset,84:InputSyncDetect,84:ReaderRe set,91:ReaderReset,92:InputSyncDetect,92:ReaderReset,93:InputSyncDetect,93 :ReaderReset,94:InputSyncDetect,94:ReaderReset,A1:ReaderReset,A2:InputSync Detect,A2:ReaderReset,A3:InputSyncDetect,A3:ReaderReset,A3:RocketPortNoEOT ,A4:InputSyncDetect,A4:ReaderReset,C1:ReaderReset,C2:InputSyncDetect,C2:Re aderReset,C3:InputSyncDetect,C3:ReaderReset,C4:InputSyncDetect,C4:ReaderRe set,E1:ReaderReset,E2:InputSyncDetect,E2:ReaderReset,F1:ReaderReset,F2:Inp utSyncDetect,F2:ReaderReset: Resets caused by brief power outages as also reported by SMP Greg K. 03/31/2005 12:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/03/31 09:43:09 03/31/2005 12:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/03/31 09:43:09 03/31/2005 12:02 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/31 09:43:09 03/31/2005 12:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/03/31 09:43:09 03/31/2005 12:02 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/31 09:42:45 03/31/2005 12:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/03/31 09:42:44 03/31/2005 12:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/03/31 09:42:44 03/31/2005 12:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/03/31 09:42:29 03/31/2005 12:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/03/31 09:42:29 03/31/2005 12:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/03/31 09:42:28 03/31/2005 08:45 Scott_Li An In/Pre-Season site visit was conducted by Dave and Scott in order to ensure that the interrogation platforms were set to their base configuration prior to the peak out-migration period. Most sites had already been reset but were revisited anyway in order to go over some the SByC activities and mild changes to the base configuration files. 03/30/2005 18:05 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/03/30 15:50:35 03/30/2005 18:05 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/03/30 15:50:35 03/30/2005 18:05 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/30 15:50:35 03/30/2005 18:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/03/30 15:50:35 03/30/2005 18:04 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/30 15:50:31 03/30/2005 18:04 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/03/30 15:50:31 03/30/2005 18:04 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/03/30 15:50:31 03/30/2005 18:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/03/30 15:50:29 03/30/2005 18:04 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/03/30 15:49:53 03/30/2005 18:04 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/03/30 15:49:53 03/30/2005 18:04 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/30 15:49:53 03/30/2005 18:04 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/03/30 15:49:53 03/30/2005 18:04 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/30 15:49:34 03/30/2005 18:04 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/03/30 15:49:34 03/30/2005 18:04 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/03/30 15:49:34 03/30/2005 18:04 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/03/30 15:49:33 03/30/2005 18:04 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/30 15:44:21 03/30/2005 18:04 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/30 15:41:26 03/30/2005 12:05 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/03/30 07:59:23 03/28/2005 16:22 Scott_Li FYI.. Given the response from the COE regarding remote access, I will load the COE VPN on the smolt server so we in Kennewick have at least 1 option to access these data collection PC's. 03/28/2005 06:05 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/03/28 05:43:44 03/28/2005 06:04 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/03/28 05:43:38 03/18/2005 15:03 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/03/18 13:06:54 03/18/2005 15:03 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/03/18 13:06:53 03/18/2005 15:03 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/18 13:06:52 03/18/2005 15:03 DGE_Robo Sample_100% (A_S100) changed from 'ON' to 'OFF' at 2005/03/18 13:06:52 03/18/2005 15:03 DGE_Robo Sample_100% (A_S100) changed from 'OFF' to 'ON' at 2005/03/18 13:06:50 03/18/2005 15:03 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/18 13:06:50 03/18/2005 15:03 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/18 13:06:30 03/18/2005 15:03 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/18 13:05:53 03/18/2005 15:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/03/18 13:04:37 03/18/2005 15:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/03/18 13:04:35 03/18/2005 15:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/03/18 13:04:07 03/18/2005 15:02 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/03/18 13:04:07 03/18/2005 15:02 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/03/18 13:04:07 03/18/2005 15:02 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/03/18 13:04:07 03/18/2005 15:02 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/03/18 13:04:07 03/18/2005 13:37 Troy The terminal strip in the PV600 enclosure was replaced with a newer terminal strip and the PV600 was individually fused. The sample indication light was pulled in order to order a replacement. This light will be replace when PSMFC Kennewick has a new one in hand. 03/18/2005 12:02 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/03/18 11:25:45 03/18/2005 12:02 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/03/18 11:25:45 03/18/2005 12:02 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/03/18 11:25:45 03/18/2005 12:02 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/03/18 11:25:45 03/18/2005 12:02 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/03/18 11:25:44 03/17/2005 15:02 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/03/17 14:51:59 03/17/2005 15:02 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/03/17 14:51:53 03/17/2005 15:02 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/03/17 12:17:20 03/17/2005 15:02 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/03/17 12:17:14 03/10/2005 16:53 Dave I've installed the new jdj_150 site map illustrations to the production and development Web servers, and updated the corresponding records in the p&d site_diagram tables. 03/08/2005 12:44 Dave I pcA'd in and performed the standard pre-season configuration. 1) Moved last year's data files from the archive directory to the "Previous Year's Data" directory. 2) Deleted all counter files. 3) Copied the updated ignor.tag and JDJ-GEN.HW1 and HW2 files to the PTAGIS FTP server, and copied the updated JDJ-GEN.MAP and JDJ-GEN.DB files from the server to the clients. Also copied the updated WATCH.TAG file from the server to JDJ-PC2. 4) Stopped data collection, took MultiMon to DOS, cleared all configuration files, and then started MultiMon from scratch, in order to flush all latent configuration data. 5) Restored all JDJ-GEN configuration files. 6) Reset the PC clocks to within 1 second of each other and Atomic Time. In the absence of any SbyC requests, the computer platforms are ready for operation (including gate tests) when the facility waters up on April 1. 03/08/2005 10:45 Dave I updated the list of JDJ Timer tags registered in the ptagis3.test_tags table, to reflect the addition of the tags associated with the new Adult Fish Return antennas 61 and 62. 03/08/2005 09:11 Darren The new Adult Fish Return monitor was completed yesterday. The ignor.tag file as well as the JDJ-GEN hardware and map files were changed to reflect the new monitor. All communications to and from the transceiver were tested and timer tags were fired to validate the "ignore" AC. The testing was completed at 15:00 yesterday (3-7-05). Dave M. is going to retrieve the files and post them to the ftp server. 03/01/2005 16:16 Carter_S Adult Fish Return monitor is added to PTAGIS server 3/1/2005: JDJ - John Day Dam Juvenile --------------------------------------------------------------------- - Current Configuration -> Seq Nbr: 150 Main? Y, Active? Y, Parallel_A_B? A, Poll? N Current Configuration: Seq Nbr 150 -> 1-Mar-05 To Present Comment: Added Adult Separator Monitor to site configuration. Monitors in Sort_Str sequence: Nbr 8 -> ADULT FISH RETURN Mon_Ctgry_Str: RVR, Entry_Y_N? Y, Exit_Y_N? Y, Sort_Str: 8 (Coil,Controller): (61,61) (62,62) Nbr 1 -> SbyC SEPARATOR GATE Mon_Ctgry_Str: UNK, Entry_Y_N? Y, Exit_Y_N? N, Sort_Str: A1 (Coil,Controller): (A1,00) (A2,01) (A3,10) (A4,11) Nbr 2 -> SAMPLE ROOM Mon_Ctgry_Str: UNK, Entry_Y_N? N, Exit_Y_N? N, Sort_Str: B1 (Coil,Controller): (51,04) (52,05) (53,14) (54,15) Nbr 3 -> RIVER EXIT Mon_Ctgry_Str: RVR, Entry_Y_N? N, Exit_Y_N? Y, Sort_Str: B2 (Coil,Controller): (81,02) (82,03) (83,12) (84,13) Nbr 4 -> SbyC GATE Mon_Ctgry_Str: UNK, Entry_Y_N? N, Exit_Y_N? N, Sort_Str: B3 (Coil,Controller): (C1,06) (C2,07) (C3,16) (C4,17) Nbr 5 -> SAMPLE / SbyC EXIT Mon_Ctgry_Str: RVR, Entry_Y_N? N, Exit_Y_N? Y, Sort_Str: C2 (Coil,Controller): (91,08) (92,09) (93,18) (94,19) Nbr 6 -> SbyC EAST TANK Mon_Ctgry_Str: UNK, Entry_Y_N? N, Exit_Y_N? N, Sort_Str: D1 (Coil,Controller): (E1,0A) (E2,1A) Nbr 7 -> SbyC WEST TANK Mon_Ctgry_Str: UNK, Entry_Y_N? N, Exit_Y_N? N, Sort_Str: D2 (Coil,Controller): (F1,0B) (F2,1B) 02/28/2005 11:53 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/02/28 07:31:10 02/23/2005 17:53 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/02/23 15:14:07 02/23/2005 17:53 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/02/23 15:14:06 02/23/2005 14:53 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/02/23 14:09:37 02/23/2005 09:12 darren@r 51:ReaderReset,51:TestTagFailure,52:InputSyncDetect,52:InputSyncLost,52:Re aderReset,53:InputSyncDetect,53:InputSyncLost,53:ReaderReset,53:TestTagFai lure,54:InputSyncDetect,54:InputSyncLost,54:ReaderReset,54:TestTagFailure, 81:ReaderReset,82:InputSyncDetect,82:InputSyncLost,82:ReaderReset,83:Input SyncDetect,83:InputSyncLost,83:LowExcCurrent,83:ReaderReset,84:InputSyncDe tect,84:InputSyncLost,84:ReaderReset,91:ReaderReset,92:InputSyncDetect,92: InputSyncLost,92:ReaderReset,92:TestTagFailure,93:InputSyncDetect,93:Input SyncLost,93:LowExcCurrent,93:ReaderReset,93:TestTagFailure,94:InputSyncDet ect,94:InputSyncLost,94:LowExcCurrent,94:ReaderReset,A1:ReaderReset,A2:Inp utSyncDetect,A2:InputSyncLost,A2:ReaderReset,A2:TestTagFailure,A3:InputSyn cDetect,A3:InputSyncLost,A3:ReaderReset,A4:InputSyncDetect,A4:InputSyncLos t,A4:ReaderReset,C1:ReaderReset,C1:TestTagFailure,C2:InputSyncDetect,C2:In putSyncLost,C2:ReaderReset,C2:TestTagFailure,C3:InputSyncDetect,C3:InputSy ncLost,C3:ReaderReset,C3:Te! stTagFailure,C4:InputSyncDetect,C4:InputSyncLost,C4:ReaderReset,E1:ReaderR eset,E1:TestTagFailure,E2:InputSyncDetect,E2:InputSyncLost,E2:ReaderReset, F1:ReaderReset,F2:InputSyncDetect,F2:InputSyncLost,F2:ReaderReset,F2:TestT agFailure: These alarms were generated by a power loss caused by PSMFC while installing the new monitor on the adult exit pipe. The power has been restored and all transceivers have been checked. 02/22/2005 14:53 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/02/22 12:10:27 02/22/2005 14:53 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/02/22 12:10:27 02/22/2005 14:53 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/02/22 12:10:27 02/22/2005 14:53 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/02/22 12:10:27 02/22/2005 14:53 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/02/22 12:10:27 02/22/2005 11:53 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/02/22 11:58:57 02/22/2005 11:53 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/02/22 11:58:57 02/22/2005 11:53 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/02/22 11:58:57 02/22/2005 11:53 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/02/22 11:58:57 02/22/2005 11:53 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/02/22 11:58:55 02/16/2005 09:39 darren@r 51:ReaderReset,52:InputSyncDetect,52:ReaderReset,53:InputSyncDetect,53:Rea derReset,54:InputSyncDetect,54:ReaderReset,81:ReaderReset,82:InputSyncDete ct,82:ReaderReset,83:InputSyncDetect,83:ReaderReset,84:InputSyncDetect,84: ReaderReset,91:ReaderReset,92:InputSyncDetect,92:ReaderReset,93:InputSyncD etect,93:ReaderReset,94:InputSyncDetect,94:ReaderReset,A1:ReaderReset,A2:I nputSyncDetect,A2:ReaderReset,A3:InputSyncDetect,A3:ReaderReset,A4:InputSy ncDetect,A4:ReaderReset,C1:ReaderReset,C2:InputSyncDetect,C2:ReaderReset,C 3:InputSyncDetect,C3:ReaderReset,C4:InputSyncDetect,C4:ReaderReset,E1:Read erReset,E2:InputSyncDetect,E2:ReaderReset,F1:ReaderReset,F2:InputSyncDetec t,F2:ReaderReset: It appears that there was a pwoer outage at the facility. I will verify this through the DGE PLC report. 02/10/2005 12:53 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/02/10 09:54:16 02/10/2005 12:53 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/02/10 09:54:16 02/10/2005 12:53 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/02/10 09:54:16 02/10/2005 12:53 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/02/10 09:54:16 02/10/2005 12:53 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/02/10 09:54:15 02/10/2005 08:23 Darren The power to the PITtag room was disconnected so that the new montior transceiver enclosure could be wired yesterday. The power was not restored last night because the facility operation personnel was not on- site when the work was finished. I have talked with Dale Quinton in the Electrical shop and he has requested that operations clear the lockout and restore power. He will notify me when this has been accomplished. 02/09/2005 15:09 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/02/09 14:56:35 02/09/2005 15:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/02/09 14:56:35 02/09/2005 15:09 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/02/09 14:56:35 02/09/2005 15:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/02/09 14:56:35 02/09/2005 15:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/02/09 14:56:34 02/09/2005 09:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'OFF' to 'ON' at 2005/02/09 08:54:34 02/09/2005 09:09 DGE_Robo SByC_Enable (SBC) changed from 'OFF' to 'ON' at 2005/02/09 08:54:34 02/09/2005 09:09 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/02/09 08:54:34 02/09/2005 09:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'CLOSED' to 'OPEN' at 2005/02/09 08:54:34 02/09/2005 09:09 DGE_Robo AC_Power (AC_Power) changed from 'OFF' to 'ON' at 2005/02/09 08:54:34 02/09/2005 09:09 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/02/09 08:52:15 02/09/2005 09:09 DGE_Robo DivertDuringSample (A_DDSample) changed from 'ON' to 'OFF' at 2005/02/09 08:52:15 02/09/2005 09:09 DGE_Robo SByC_Enable (SBC) changed from 'ON' to 'OFF' at 2005/02/09 08:52:15 02/09/2005 09:09 DGE_Robo PrimaryBypass (PrimaryBypass) changed from 'OPEN' to 'CLOSED' at 2005/02/09 08:52:15 02/09/2005 09:09 DGE_Robo AC_Power (AC_Power) changed from 'ON' to 'OFF' at 2005/02/09 08:52:14 02/01/2005 13:26 Dave I've published a revised map for the current (Cnfg #140) PIT Tag Interrogation installation at the John Day Dam Juvenile Monitoring Facility (JDJ). This map replaces the original illustration created in 2000. It uses the graphical conventions we have implemented in the last couple of years to illustrate our installations at the other Columbia Basin juvenile and adult fish facilities. There are no substantive changes to the identities or geometries of the PIT tag detectors represented in the new illustration. The new graphics files (JDJ_140.AI, EPS, JPG, and PDF) are located in the JDJ directory of blueback://~pittag/doc/Site_Map/TJK; the JPG and PDF files were also added to blueback://~pittag/doc/Site_Map/PRODUCTION. I've copied the JPD and PDF files to the respective site locations on our new production and development Web servers. Since the map references the current #140 site configuration, it was not necessary to update the entry for this configuration in the site_diagram table in either the production or development database. 01/31/2005 11:12 Dave The 2004 MultiMon operational configuration files have been archived on the PTAGIS FTP server at ftp://ftp.ptagis.org/multimon/Site_Configurations/2004-Config. 01/26/2005 12:08 DGE_Robo SampleGateBypass (SBypass) changed from 'OFF' to 'ON' at 2005/01/26 09:11:44 01/26/2005 12:08 DGE_Robo SampleGateBypass (SBypass) changed from 'ON' to 'OFF' at 2005/01/26 09:11:35 01/16/2005 10:50 Troy PSMFC is aware this site is not loading. This situation will continue to be monitored and more attempts to PCA into this site will be made. This site is currently not active so no fish data is being lost. 01/16/2005 08:40 Troy This site has not loaded yet today. Will wait until the next load to see if it straightens out. This site is down for the winter so no fish data is being lost. 01/16/2005 08:11 troy This site has not loaded this morning. Will wait to see if it straightens out by the next load before persuing this further as this site is de- watered for the winter. ####End of Event Log for JDJ###