EVENT LOG FOR SITE PRA The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/26/2006 07:12 scottl@r 01:LowExcCurrent,02:LowExcCurrent,04:Overrun: Will tune transcievers on the next site visit in order suppress alarm messages. 12/12/2006 10:43 bturley@ 01:LowExcCurrent,02:LowExcCurrent,03:LowExcCurrent,04:Overrun: Low Exciter Current and Overruns occurred because the ladder is dewatered. These readers were in standby since early November but apparently they were re-booted and went into scan mode. I put readers 01, 02, 03, and 04 back into standby 10/27/2006 12:16 bturley@ 08:Overrun,08:TestTagFailure: Overrun and test tag failure acknowledged 09/25/2006 12:13 bturley@ 08:TestTagFailure: No indication why test tag failed. 09/25/2006 12:12 bturley@ 08:TestTagFailure: No indication why test tag failed. 09/08/2006 08:40 bturley@ 08:TestTagFailure: test tag failure acknowledged 08/31/2006 14:45 bturley@ 08:TestTagFailure: test tag failure acknowledged 07/10/2006 09:05 myriad36 08:TestTagFailure: Test tag failure, reason unknown; possibly due to DRS/noise eval data. 07/10/2006 09:04 myriad36 05:TestTagFailure: Test tag failure, reason unknown; possibly due to DRS/noise eval data. 06/22/2006 08:42 bturley@ 08:TestTagFailure: Test tag failed for unknown reason 06/12/2006 07:14 myriad36 08:TestTagFailure: Test tag failure reason unknown; possibly due to Noise Report at the same time. 05/23/2006 10:18 bturley@ 07:HighTemp,08:TestTagFailure: High temp alarm caused because the air conditioning in the trailer that the transceivers are in hasn't been turned on. I alerted Grant PUD personnel to the problem. So, they are having the AC turned on. Test tag failure on coil 08 caused by unknown reason. 05/23/2006 10:15 bturley@ 05:Overrun: Unexplained noise caused the overrun. Looks like an isolated event. 05/23/2006 10:15 bturley@ 02:Overrun: Unexplained noise causing the overrun. Looks like an isolated event. 05/08/2006 07:16 myriad36 08:Overrun,08:TestTagFailure: Overrun possible due to user activity onreader (H command, displays list of commands). Test tag failure possibly due to Noise Report during the same time. 05/08/2006 07:15 myriad36 08:Overrun,08:TestTagFailure: Overrun possible due to user activity on reader (H command, displays list of commands). Test tag failure possibly due to Noise Report during the same time. 04/06/2006 10:20 bturley@ 01:LowExcCurrent,02:LowExcCurrent,04:LowExcCurrent,05:LowExcCurrent,08:Low ExcCurrent: Low exciter current alarms occurred during maintenance. I flashed the transceivers with 5.0 software and re-tuned them. This is when the low exciter current alarms occurred. 04/06/2006 07:14 myriad36 08:TestTagFailure: Test tag fired during a Noise report. This may have caused the test tag to fail to read. 04/04/2006 07:25 BruceG@r 08:TestTagFailure: No apparent reason for failure. 03/30/2006 12:17 myriad36 08:TestTagFailure: Test tag failed for no noticable reason. 03/07/2006 08:51 bturley@ 08:TestTagFailure: Unexplained test tag failure 01/25/2006 07:35 bturley@ 08:TestTagFailure: Test tag failure for no apparent reason. Transceiver is tuned and noise is low. 01/13/2006 13:06 bturley@ 06:LowExcCurrent,07:LowExcCurrent,08:LowExcCurrent,08:TestTagFailure: Low Exciter Current alarms caused by dewatered ladder. 01/04/2006 08:28 bturley@ 06:LowExcCurrent,07:LowExcCurrent,08:LowExcCurrent: Readers lost power, and when they re-set they came up with a low current alarm. Alarm was probably caused by the fact that the ladders are de-watered. 01/01/2006 12:40 PTOC_Bot Annual log file initiation for PRA #### End of Event Log for PRA ###