EVENT LOG FOR SITE PRA The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 12/01/2010 12:17 bturley@ 05:LowExcCurrent,05:LowLithium,06:LowLithium: Low lithium and low exciter current alarms acknowledged. The low exciter current was caused by the bad lithium battery not saving the transceiver settings 11/23/2010 11:42 bturley@ 06:LowLithium: Low lithium alarm acknowledged. I will replace it on my next trip to PRA. 11/23/2010 11:41 bturley@ 01:LowExcCurrent: Low current alarm caused by the ladder being dewatered. I put this transceiver in standby until the ladder is watered back up. 11/23/2010 11:39 Brett The left ladder was dewatered on Monday 11/22/10 at about 06:00 am PST. I put transceivers 01, 02, 03 and 04 in standby. The right ladder is still operational. No word yet as to when the left ladder will be watered up and the right one dewatered. 11/19/2010 08:13 bturley@ 06:LowLithium: Low lithium alarm acknowledged. 11/12/2010 08:03 bturley@ 06:LowLithium: Low lithium alarm acknowledged 11/01/2010 08:41 bturley@ 06:LowExcCurrent,06:LowLithium: Low exciter current and low lithium alarm acknowledged. 09/21/2010 09:16 bturley@ 04:LowExcCurrent,08:LowExcCurrent: Low exciter current alarms occurred while replacing lithium batteries in transceivers. 09/20/2010 14:53 Brett I installed new lithium batteries to the transceivers and installed the country code patch to Minimon to allow it to recognize 384 prefix tags 07/21/2010 12:09 bturley@ 08:TestTagFailure: Test tag failure acknowledged 07/08/2010 13:53 bturley@ 03:Overrun,08:TestTagFailure: Overrun and test tag failure acknowledged 06/03/2010 13:17 bturley@ 08:TestTagFailure: Test tag failure acknowledged 05/11/2010 17:59 Brett O&M visit. Configured the new firewall on PC's. Tuned antennas and deleted buffers 04/06/2010 14:00 Brett The right ladder was watered up and is fully operational as of 3/31/10 at 3:00 pm PST. 03/26/2010 15:18 Brett Turned on and checked diagnostics of the OLAFT mux. Tuned reader 02 and changed the lithium battery of transceiver 08. 03/22/2010 15:17 bturley@ 08:LowExcCurrent,08:LowLithium: Low exciter current alarms acknowledged. 03/10/2010 12:32 Brett The left fishway was watered up on 2/17/10. The right fishway was de-watered on 2/17/10. It is scheduled to be watered up on 4/7/10. However, it may be watered up earlier if the their winter maintenance is completed in time. I will post a log event when the ladder is watered up. 03/10/2010 11:46 bturley@ 06:LowExcCurrent,07:LowExcCurrent,08:LowExcCurrent,08:LowLithium: Low exciter alarm acknowledged. Ladder is dewatered. 02/02/2010 09:31 bturley@ 01:LowExcCurrent: Low exciter current alarm acknowledged. The ladder is dewatered. 01/07/2010 10:07 Brett O&M visit to PRA on 1/6/10. Data PC 1 had stopped sending data on 1/1/10. I reset PC1 and submitted the missing files from PC2 to PTAGIS. The computers are now working properly. Also, I tuned transceiver 06 which was out of tune and had excessive noise. 01/01/2010 00:00 PTOC_Bot Annual log file initiation for PRA #### End of Event Log for PRA ###