EVENT LOG FOR SITE SUJ Most recent activity to be listed first. First line of each entry lists date, time and who is reporting. Subsequent lines of each entry aligned under Time column. Do not use tabs, only spaces. Date Time Who What ---------- ----- -------- ----------------------------------------------- 12/01/2003 15:09 Kirk Performed maintenance and trouble-shooting on SUJ computer from 10 am to noon: Rebooted computer to solve dial-up connection problems. Installed version 1.4.2 of Minimon. Sullivan bypass was shut down for cleaning and no fish were moving through the bypass. 04/22/2003 13:40 Kirk Changed file interval from 8 hours to 6 hours to synchronize with changes in the PTAGIS warning interval - change made at 1600 on April 21,2003. 03/20/2003 15:51 Kirk Replaced UPS at Sullivan Plant on Tuesday, March 11, about 12:30 pm. Brief shutdown during switchover. Computer is plugged into one UPS and transceiver is plugged into a second UPS. 03/19/2003 14:34 Kirk Replaced UPS at Sullivan Plant on Tuesday, March 11, about 12:30 pm. Brief shutdown during switchover. Computer is plugged into one UPS and transceiver is plugged into a second UPS. 03/01/2003 16:06 Kirk UPS at Sullivan Plant failed sometime around 0500 February 25. Notice of problem was received on February 26 and was fixed by 1400. 01/01/2003 12:19 Dave Initialized new event log for 2003. 2002 event log has been archived. ####End of Event Log for SUJ###