EVENT LOG FOR SITE WEA The first line of each entry contains a date/time stamp & who is reporting. The most recent entry is listed first. Date Time Who ---------- ----- -------- 10/06/2009 08:59 Brett Due to a power issue,transceiver 02 was down from 9/25 at 17:18 to 10/05 at 10:54. It looks like there was a possible power outtage or power surge that caused transceiver 01 thru 04 to lose momentarily lose power. However, the "warning light" on the UPS on transceiver 02 indicated that there was a power spike that caused the UPS to shut down, so transceiver 02 never booted back up. The other 3 transceivers on the ladder re-booted normally. 09/29/2009 13:12 bturley@ 03:BadOscFreq: Bad Oscillator Frequency alarm acknowledged 09/16/2009 13:30 Brett I installed new data computers and UPS battery backups yesterday. Also checked and tuned transceivers as needed. 08/06/2009 15:29 Tom Beginning at 0740 on 07/29/09, flow was reduced in the left (east) ladder to facilitate work in the collection gallery. Flow reduction resulted in increased noise but did not impeded PIT-tag detection. Full flow was restored by 1340. 07/21/2009 12:08 Brett There are network issues at WEA, so data has not been received since yesterday at noon. We are working to resolve the issue and we should be getting data from WEA again soon. 04/17/2009 16:29 Tom WEA left ladder was watered up on 01/21/09 at 1900 hours following annual maintenance. WEA left ladder was de-watered on 01/22/09 at 1500 hours for additional maintenance. WEA left ladder was watered up on 01/29/09 at 1100 hours, ending additional maintenance. WEA right ladder was de-watered on 01/29/09 at 1500 hours for annual maintenance. WEA right ladder was watered up on 02/10/09 at 1700 hours, ending annual maintenance. WEA left ladder was de-watered on 04/07/09 at 0753 hours to remove study equipment. WEA left ladder was watered up on 04/07/09 at 0947 hours, ending removal of study equipment. WEA right ladder was de-watered on 04/07/09 at 0848 hours to remove study equipment. WEA right ladder was watered up on 04/07/09 at 0947 hours, ending removal of study equipment. Tom Kahler Fisheries Biologist P.U.D. No. 1 of Douglas County 1151 Valley Mall Parkway East Wenatchee, WA 98802 Bus: 509 884-7191 Fax: 509 884-0553 tkahler@dcpud.org 01/23/2009 08:49 Brett WEA left ladder was watered up on 1/21. The right ladder is scheduled to be de-watered on 1/29. 01/01/2009 00:00 PTOC_Bot Annual log file initiation for WEA #### End of Event Log for WEA ###