Skip to Main Content
PTAGIS logo link back to home page

Interrogation Site Metadata

Search by typing either a site name, site code, organization, or site type.

UMW - Umatilla R Recycled Water Fac

Status:   Active - Operational
Site Type: Instream Remote Detection System  |  Organization: U.S. Fish and Wildlife Service
General Operational Period: Year Round
Start Date: 1/9/2018 12:00 AM

UMW is an instream detection array in the Umatilla River adjacent to the City of Hermiston’s Recycled Water Plant. One row of four 3ft X 20ft antennas are laid in a pass over orientation, covering more than the entire wetted width of the river at base flows. Each antenna has a submerged IS1001 node which are connected to an onshore IS1001-MC. The site is grid powered and operates year-round.

Current Operations

Last File Loaded: UMW-2021-001-P-UMW.xml
Date Last File Loaded: 5/11/2021 9:21 AM
Date Last File Opened: 1/1/2021 12:00 AM
Date Last File Closed: 2/16/2021 2:29 PM
Last Observation Tag: 3D9.1C2D25541C
Last Observation Date: 4/20/2021 2:37 PM
Detection Summary: Last Day's Observations

Contacts

Primary Contact:

Nate Queisser
timothy_queisser@fws.gov
317-966-2074

Data Steward:

Will Simpson
william_simpson@fws.gov
360-604-2500

Location

Coordinates: 45.861949, -119.314651  |  River Km: 465.009

Operational History

Operational history describes the period the site was interrogating for PIT tags. The comments provide anecdotal information about the operation of the site during this period. Site operational periods are updated typically at the end of the calendar year.

Year Start Date End Date Comments
2021
2020 2/7/2020 12:00 AM 5/21/2020 12:00 AM Start and end dates based on timer tags. See event logs for additional operational information.
2019 1/1/2019 12:00 AM 9/26/2019 12:00 AM Start and end dates based on timer tags.
2018 1/9/2018 12:00 AM 12/28/2018 12:00 AM Site down February 8 - June 12. Only antenna 4 operational after December 10.

Configuration

Configuration metadata includes details about the equipment used at the site to detect and record PIT tags. A new configuration sequence record is created when equipment is added or removed from the site and the period of time it was active. A configuration sequence without an End Date is currently active.

Select Configuration Number:
Start Date:  1/8/2018
End Date:  ----

Site Configuration Diagrams:

Equipment History

Select a type to view the history of equipment installed at this site. A missing End Date implies the information about the equipment is current.

Select Equipment Type:
Equipment Code Description Start Date End Date

No Photos

Event Log Summary

Event Date Event Type Comments
5/21/2020 12:36:00 AM General Antenna 1 cable failure. Antenna 1 is no longer operating. The only remaining operational antenna is antenna 3.
9/12/2019 11:36:00 AM SiteUp Cables repaired. Antenna coils 01 and 03 operational. Antennas 02 and 04 are still down.
4/19/2019 2:33:00 PM SiteDown Cable failure, no antenna coils are operational
12/10/2018 1:40:00 PM General Only antenna 4 attached and operational.
6/12/2018 11:17:00 AM SiteUp Antenna cable replaced, site up.
2/8/2018 12:07:00 PM SiteDown Site down sometime between 2/8/2018 12:07 and 18:06
1/9/2018 1:49:00 PM SiteUp Site begins operation

No Archived Event Logs